The DOI matches its Crossref record.
THE RANGE AND VARIABILITY OF THE BLOOD FLOW IN THE HUMAN FINGERS AND THE VASOMOTOR REGULATION OF BODY TEMPERATURE
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The variation in the quasi-DC component is due to many factors: the optical properties of the tissue, average blood volume, respiration, vasomotor activity, vasoconstrictor waves, Traube Hering Meyer waves, and thermoregulation [4,5,6,7,8,9,10,11,12,13,14].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [5]
Citations
Cited by
Sorted by citations
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
“…component varies slowly due to respiration, vasomotor activity and vasoconstrictor waves, Traube Hering Mayer (THM) waves and also thermoregulation (Burton 1939, Burton and Taylor 1940, Hertzman and Dillon 1940b, Hertzman and Roth 1942a, 1942b, 1942c, Hertzman and Flath 1963, Hyndman et al 1971,…”
BackgroundHemodynamic regulation: investigation by spectral analysis
AKSELROD, S., Gordon, D., Madwed, J. B., Snidman, N. C., Shannon, D. C., & Cohen, R. J. (1985) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1985.249.4.h867 · Cited by 1,295
“The third peak of the spectrum, identified by Burton (7) and studied by Sayers and co-workers (27), occurs typically at a central frequency from 0.”
BackgroundMethodInfluentialDesigning thermoelectric generators for self-powered wearable electronics
Suarez, F., Nozariasbmarz, A., Vashaee, D., & Öztürk, M. C. (2016) · Energy & Environmental Science · doi:10.1039/c6ee00456c · Cited by 443
Cutaneous Vasodilator and Vasoconstrictor Mechanisms in Temperature Regulation
Johnson, J. M., Minson, C. T., & Kellogg, D. L. (2014) · Comprehensive physiology · doi:10.1002/cphy.c130015 · Cited by 483
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348
Metadata
- Authors
- Burton, A. C.
- Affiliations
- University of Pennsylvania (US)
- Corresponding author
- Burton, A. C.
- ORCID
- Burton, A. C.
- Venue
- American Journal of Physiology-Legacy Content
- Publisher
- American Physiological Society
- Published
- 1939-09-30
- Volume
- 127
- Issue
- 3
- Pages
- 437-453
- ISSN
- 0002-9513 (ISSN-L)
- OpenAlex
- W2214038234
- Cited by
- 333
- References
- 0
- Citations by year
- 2025: 1 · 2024: 3 · 2023: 2 · 2022: 2 · 2021: 9 · 2020: 2 · 2019: 3 · 2018: 7 · 2017: 5 · 2016: 7 · 2015: 6 · 2014: 8 · 2013: 8 · 2012: 5
- FWCI
- 10.87
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Physiology-Legacy Content (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- finger blood flow, regional blood flow, vasomotor control, thermoregulation, skin blood flow, finger
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review