Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 348

The DOI matches its Crossref record.

Distribution of intranasal instillations in mice: effects of volume, time, body position, and anesthesia

Southam, D. S., Dolovich, M., O'Byrne, P. M., Inman, M. D.·2002·American Journal of Physiology-Lung Cellular and Molecular Physiology

Abstract

Intranasal instillation techniques are used to deliver various substances to the upper and lower respiratory tract (URT and LRT) in mice. Here, we quantify the relative distribution achieved with intranasal delivery of a nonabsorbable tracer,99m Tc-labeled sulfide-colloid. Relative distribution was determined by killing mice after instillation and quantifying the radioactivity in dissected tissues using gamma scintigraphy. A significant effect of delivery volume on relative distribution was observed when animals were killed 5 min after instillation delivered under gas anesthesia. With a delivery volume of 5 μl, no radiation was detected in the LRT; this increased to a maximum of 55.7 ± 2.5% distribution to the LRT when 50 μl were delivered. The majority of radiation not detected in the LRT was found in the URT. Over the course of the following 1 h, radiation in the LRT remained constant, while that in the URT decreased and appeared in the gastrointestinal tract. Instillation of 25 μl into anesthetized mice resulted in 30.1 ± 6.9% distribution to the LRT, while only 5.3 ± 1.5% ( P < 0.05) of the same volume was detected in the LRT of awake mice. Varying the body position of mice did not affect relative distribution. When using intranasal instillation, the relative distribution between the URT and LRT and the gastrointestinal tract is heavily influenced by delivery volume and level of anesthesia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajplung.00173.2001

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 348

Metadata

Authors
Southam, D. S., Dolovich, M., O'Byrne, P. M., & Inman, M. D.
Venue
American Journal of Physiology-Lung Cellular and Molecular Physiology
Published
2002-04-01
Volume
282
Issue
4
Pages
L833-L839
ISSN
  • 1040-0605 (ISSN-L)
  • 1522-1504
OpenAlex
W2134596993
Cited by
348
References
0
FWCI
2.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Distribution of intranasal instillations in mice: effects of volume, time, body position, and anesthesia. https://app.cochat.ai/papers/10.1152/ajplung.00173.2001
The paper
Southam, D. S., Dolovich, M., O'Byrne, P. M., & Inman, M. D. (2002). Distribution of intranasal instillations in mice: effects of volume, time, body position, and anesthesia. American Journal of Physiology-Lung Cellular and Molecular Physiology. https://doi.org/10.1152/ajplung.00173.2001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.