The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Sample entropy analysis of neonatal heart rate variability
Abstract
Abnormal heart rate characteristics of reduced variability and transient decelerations are present early in the course of neonatal sepsis. To investigate the dynamics, we calculated sample entropy, a similar but less biased measure than the popular approximate entropy. Both calculate the probability that epochs of window length m that are similar within a tolerance r remain similar at the next point. We studied 89 consecutive admissions to a tertiary care neonatal intensive care unit, among whom there were 21 episodes of sepsis, and we performed numerical simulations. We addressed the fundamental issues of optimal selection of m and r and the impact of missing data. The major findings are that entropy falls before clinical signs of neonatal sepsis and that missing points are well tolerated. The major mechanism, surprisingly, is unrelated to the regularity of the data: entropy estimates inevitably fall in any record with spikes. We propose more informed selection of parameters and reexamination of studies where approximate entropy was interpreted solely as a regularity measure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimating the Dimension of a Model
Schwarz, G. (1978) · The Annals of Statistics · doi:10.1214/aos/1176344136 · Cited by 47,033
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Physiological time-series analysis using approximate entropy and sample entropy
Richman, J. S., & Moorman, J. R. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.278.6.h2039 · Cited by 7,880
Self-citationApproximate entropy as a measure of system complexity.
Pincus, S. M. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.6.2297 · Cited by 5,811 · cited 4×
“There are penalties, however, for criteria that are too relaxed (16).”
BackgroundInfluentialThe Analysis of Time Series: An Introduction with R
Chatfield, C., & Xing, H. (2019) · Chapman & Hall/CRC eBooks · doi:10.1201/9781351259446 · Cited by 1,803
Physiological time-series analysis: what does regularity quantify?
Pincus, S. M., & Goldberger, A. L. (1994) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1994.266.4.h1643 · Cited by 1,315
Approximate entropy (ApEn) as a complexity measure
Pincus, S. (1995) · Chaos: An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.166092 · Cited by 1,213
Stoll, B. J., Gordon, T., Korones, S. B., Shankaran, S., Tyson, J. E., Bauer, C. R., Fanaroff, A. A., Lemons, J. A., Donovan, E. F., Oh, W., et al. (1996) · The Journal of Pediatrics · doi:10.1016/s0022-3476(96)70191-9 · Cited by 873
A regularity statistic for medical data analysis
Pincus, S. M., Gladstone, I. M., & Ehrenkranz, R. A. (1991) · Journal of Clinical Monitoring · doi:10.1007/bf01619355 · Cited by 788
Approximate entropy: a regularity measure for fetal heart rate analysis.
Pincus, S. M., & Viscarello, R. R. (1992) · PubMed · Cited by 323
Griffin, M. P., & Moorman, J. R. (2001) · Pediatrics · doi:10.1542/peds.107.1.97 · Cited by 319
Self-citationHeart rate variability. Frequency domain analysis.
Őri, Z., Monir, G., Weiss, J., Sayhouni, X., & Singer, D. H. (1992) · PubMed · Cited by 300
Küster, H., Weiss, M., Willeitner, A. E., Detlefsen, S., Jeremias, I., Zbojan, J., Geiger, R., Lipowsky, G., & Simbruner, G. (1998) · The Lancet · doi:10.1016/s0140-6736(98)08148-3 · Cited by 275
Approximate entropy: Statistical properties and applications
Pincus, S. M., & Huang, W.-M. (1992) · Communications in Statistics - Theory and Methods · doi:10.1080/03610929208830963 · Cited by 251
ECG artifacts and heart period variability: Don't miss a beat!
Berntson, G. G., & Stowell, J. R. (1998) · Psychophysiology · doi:10.1111/1469-8986.3510127 · Cited by 223
Őri, Z., Monir, G., Weiss, J., Sayhouni, X., & Singer, D. H. (1992) · Cardiology Clinics · doi:10.1016/s0733-8651(18)30231-5 · Cited by 223
Mäkikallio, T. H., Ristimäe, T., Airaksinen, J. K. E., Peng, C., Goldberger, A. L., & Huikuri, H. V. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(97)00799-6 · Cited by 149
Mäkikallio, T. H., Seppänen, T., Niemelä, M. J., Airaksinen, J. K. E., Tulppo, M. P., & Huikuri, H. V. (1996) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00243-4 · Cited by 125
Entropy measures of heart rate variation in conscious dogs
Palazzolo, J. A., Estafanous, F. G., & Murray, P. A. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.274.4.h1099 · Cited by 96
Impact of pulsatility on the ensemble orderliness (approximate entropy) of neurohormone secretion
Veldhuis, J. D., Johnson, M. L., Veldhuis, O. L., Straume, M., & Pincus, S. M. (2001) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.2001.281.6.r1975 · Cited by 90
Quantifying Complexity and Regularity of Neurobiological Systems
Pincus, S. M. (1995) · Methods in neurosciences · doi:10.1016/s1043-9471(06)80040-6 · Cited by 88
Time-domain system for assessing variation in heart rate
Schechtman, V. L., Kluge, K. A., & Harper, R. M. (1988) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442293 · Cited by 81
Approximate entropy for testing randomness
Rukhin, A. L. (2000) · Journal of Applied Probability · doi:10.1239/jap/1014842270 · Cited by 71
Baldzer, K., Dykes, F., Jones, S. A., Brogan, M., Carrigan, T. A., & Giddens, D. P. (1989) · Pediatric Research · doi:10.1203/00006450-198909000-00004 · Cited by 67
Lipsitz, L. A., Pincus, S. M., Morin, R. J., et al. (1997) · Journal of the Autonomic Nervous System · doi:10.1016/s0165-1838(97)00028-3 · Cited by 38
Human fetuses have nonlinear cardiac dynamics
Groome, L. J., Mooney, D. M., Holland, S. B., Smith, L. A., Atterbury, J. L., & Loizou, P. C. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.2.530 · Cited by 36
Newlin, D. B., Wong, C. J., Stapleton, J. M., & London, E. D. (2000) · Neuropsychopharmacology · doi:10.1016/s0893-133x(00)00135-4 · Cited by 31
Oddis, C. V., & Finkel, M. S. (1997) · European Journal of Pharmacology · doi:10.1016/s0014-2999(96)00912-0 · Cited by 22
Cited by
The Appropriate Use of Approximate Entropy and Sample Entropy with Short Data Sets
Yentes, J. M., Hunt, N., Schmid, K. K., Kaipust, J. P., McGrath, D., & Stergiou, N. (2013) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0668-3 · Cited by 893
Sassi, R., Cerutti, S., Lombardi, F., Malik, M., Huikuri, H. V., Peng, C.-K., Schmidt, G., Yamamoto, Y., Reviewers:, D., Gorenek, B., et al. (2015) · Europace · doi:10.1093/europace/euv015 · Cited by 727
Methods derived from nonlinear dynamics for analysing heart rate variability
Voss, A., Schulz, S., Schroeder, R., Baumert, M., & Caminal, P. (2009) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2008.0232 · Cited by 590
Diagnosis of Alzheimers Disease from EEG Signals: Where Are We Standing?
Dauwels, J., Vialatte, F., & Cichocki, A. (2010) · Current Alzheimer Research · doi:10.2174/156720510792231720 · Cited by 492
Emotion recognition using wireless signals
Zhao, M., Adib, F., & Katabi, D. (2016) · Proceedings of the 22nd Annual International Conference on Mobile Computing and Networking · doi:10.1145/2973750.2973762 · Cited by 461
Metadata
- Authors
- Lake, D. E., Richman, J. S., Griffin, M. P., & Moorman, J. R.
- Venue
- American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
- Publisher
- American Physiological Society
- Published
- 2002-09-01
- Volume
- 283
- Issue
- 3
- Pages
- R789-R797
- ISSN
- 0363-6119 (ISSN-L)
- 1522-1490
- OpenAlex
- W2118183148
- Cited by
- 1,233
- References
- 29
- FWCI
- 6.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.