Intrinsic pump-conduit behavior of lymphangions
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Lymphangions, segments of lymphatic vessels bounded by valves, have characteristics of both ventricles and arteries. They can act primarily like pumps when actively transporting lymph against a pressure gradient. They also can act as conduit vessels when passively transporting lymph down a pressure gradient. This duality has implications for clinical treatment of several types of edema, since the strategy to optimize lymph flow may depend on whether it is most beneficial for lymphangions to act as pumps or conduits. To address this duality, we employed a simple computational model of a contracting lymphangion, predicted the flows at both positive and negative axial pressure gradients, and validated the results with in vitro experiments on bovine mesenteric vessels. This model illustrates that contraction increases flow for normal axial pressure gradients. With edema, limb elevation, or external compression, however, the pressure gradient might reverse, and lymph may flow passively down a pressure gradient. In such cases, the valves may be forced open during the entire contraction cycle. The vessel thus acts as a conduit, and contraction has the effect of increasing resistance to passive flow, thus inhibiting flow rather than promoting it. This analysis may explain a possible physiological benefit of the observed flow-mediated inhibition of the lymphatic pump at high flow rates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SUGA, H., & SAGAWA, K. (1974) · Circulation Research · doi:10.1161/01.res.35.1.117 · Cited by 1,330 · cited 1×
“, in a series of seminal papers (47-49), developed a relatively simple description of the heart that related ventricular chamber pressure, Pt, to chamber volume, V.”
Arterial viscoelasticity: A generalized model
Westerhof, N., & Noordergraaf, A. (1970) · Journal of Biomechanics · doi:10.1016/0021-9290(70)90036-9 · Cited by 171 · cited 1×
“These equations have been successfully used as a basis to describe the interaction of multiple vessels in a vascular network (21, 51) and are used in the present work to describe lymph flow.”
Cited by
Wiig, H., & Swartz, M. A. (2012) · Physiological Reviews · doi:10.1152/physrev.00037.2011 · Cited by 722
Contractile Physiology of Lymphatics
Zawieja, D. C. (2009) · Lymphatic Research and Biology · doi:10.1089/lrb.2009.0007 · Cited by 368
Self-citationAqueous outflow - A continuum from trabecular meshwork to episcleral veins
Carreon, T., van der Merwe, E., Fellman, R. L., Johnstone, M., & Bhattacharya, S. K. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.12.004 · Cited by 312
Capillary Fluid Exchange: Regulation, Functions, and Pathology
Scallan, J., Huxley, V. H., & Korthuis, R. J. (2010) · Colloquium Series on Integrated Systems Physiology: From Molecule to Function · doi:10.4199/c00006ed1v01y201002isp003 · Cited by 256
Modelling the lymphatic system: challenges and opportunities
Margaris, K. N., & Black, R. A. (2012) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0751 · Cited by 229
Determinants of valve gating in collecting lymphatic vessels from rat mesentery
Davis, M. J., Rahbar, E., Gashev, A. A., Zawieja, D. C., & Moore, J. E. (2011) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00133.2011 · Cited by 179
“For example, in edematous tissues, lymphatic Pin may exceed Pout and the lymphangion may behave more as a conduit, with continuous forward flow, than as a pump (23, 48); similar behavior may occur normally in intestinal lymphatics during high levels of lymph formation.”
BackgroundSelf-citationImpaired meningeal lymphatic vessel development worsens stroke outcome.
Yanev, P., Poinsatte, K., Hominick, D., Khurana, N., Zuurbier, K. R., Berndt, M., Plautz, E. J., Dellinger, M. T., & Stowe, A. M. (2020) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x18822921 · Cited by 126
Myogenic constriction and dilation of isolated lymphatic vessels
Davis, M. J., Davis, A. M., Ku, C. W., & Gashev, A. A. (2009) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01040.2008 · Cited by 78
Self-citationLymphatic pump-conduit duality: contraction of postnodal lymphatic vessels inhibits passive flow
Quick, C. M., Ngo, B. L., Venugopal, A. M., & Stewart, R. H. (2009) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00322.2008 · Cited by 40
Self-citationAdaptation of mesenteric lymphatic vessels to prolonged changes in transmural pressure
Dongaonkar, R. M., Nguyen, T. L., Quick, C. M., Hardy, J., Laine, G. A., Wilson, E., & Stewart, R. H. (2013) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00677.2012 · Cited by 38
Self-citation
Metadata
- Authors
- Quick, C. M., Venugopal, A. M., Gashev, A. A., Zawieja, D. C., & Stewart, R. H.
- Venue
- American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
- Publisher
- American Physiological Society
- Published
- 2007-04
- Volume
- 292
- Issue
- 4
- Pages
- R1510-R1518
- ISSN
- 0363-6119 (ISSN-L)
- 1522-1490
- OpenAlex
- W2147290360
- Cited by
- 116
- References
- 2
- FWCI
- 2.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.