Microsphere and dilution techniques for the determination of blood flows and volumes in conscious mice
The DOI matches its Crossref record.
Abstract
Although the mouse is the most commonly used transgenic species, little is known regarding cardiovascular and fluid homeostasis in this animal. Therefore, the reference microsphere and dilution techniques were adapted for the measurement of cardiac output (CO), regional blood flows, and intravascular fluid volumes in the conscious mouse. Previously acclimatized C3H mice were studied 4-5 h after surgery and recovery from anesthesia. Approximately 40,000 85Sr-labeled microspheres were injected into the left ventricle while a reference sample was withdrawn at one of two rates from the femoral artery. 51Cr and 125I were used for the determination of blood volume (BV), plasma volume (PV), and Fcells ratio (whole body hematocrit/large vessel hematocrit). CO and BV in the conscious mouse were 16 +/- 1.4 ml/min and 2.3 +/- 0.1 ml, respectively. Anesthesia lowered heart rate, blood pressure, PV, and altered the distribution of CO. Two successive injections of 15,000-20,000 microspheres were tolerated in the mouse without an increase in total peripheral resistance. The results indicate that the microsphere and indicator dilution techniques can be applied to study cardiovascular and fluid homeostasis in the mouse.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Physiological Parameter Values for Physiologically Based Pharmacokinetic Models
Brown, R. P., Delp, M. D., Lindstedt, S. L., Rhomberg, L. R., & Beliles, R. P. (1997) · Toxicology and Industrial Health · doi:10.1177/074823379701300401 · Cited by 1,415
Targeted drug delivery by thermally responsive polymers
Chilkoti, A., Dreher, M. R., Meyer, D. E., & Raucher, D. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(02)00041-8 · Cited by 573
Suppression of hepcidin during anemia requires erythropoietic activity
Pak, M., Lopez, M. A., Gabayan, V., Ganz, T., & Rivera, S. (2006) · Blood · doi:10.1182/blood-2006-06-028787 · Cited by 472
Drug targeting using thermally responsive polymers and local hyperthermia
Meyer, D. E., Shin, B. C., Kong, G. A., Dewhirst, M. W., & Chilkoti, A. (2001) · Journal of Controlled Release · doi:10.1016/s0168-3659(01)00319-4 · Cited by 416
Echocardiographic assessment of cardiac function in conscious and anesthetized mice
Yang, X.-P., Liu, Y.-H., Rhaleb, N.-E., Kurihara, N., Kim, H. E., & Carretero, O. A. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.277.5.h1967 · Cited by 365
Metadata
- Authors
- Barbee, R. W., Perry, B. D., Re, R. N., & Murgo, J. P.
- Venue
- American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
- Publisher
- American Physiological Society
- Published
- 1992-09-01
- Volume
- 263
- Issue
- 3
- Pages
- R728-R733
- ISSN
- 0363-6119 (ISSN-L)
- 1522-1490
- OpenAlex
- W2209578967
- Cited by
- 131
- References
- 0
- FWCI
- 2.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microsphere and dilution techniques for the determination of blood flows and volumes in conscious mice. https://app.cochat.ai/papers/10.1152/ajpregu.1992.263.3.r728
- The paper
- Barbee, R. W., Perry, B. D., Re, R. N., & Murgo, J. P. (1992). Microsphere and dilution techniques for the determination of blood flows and volumes in conscious mice. American Journal of Physiology-Regulatory, Integrative and Comparative Physiology. https://doi.org/10.1152/ajpregu.1992.263.3.r728
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.