The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Echocardiographic assessment of cardiac function in conscious and anesthetized mice
Abstract
Using a high-frequency linear transducer (15L8), we studied 1) the feasibility of performing echocardiography in nonanesthetized mice compared with mice given pentobarbital sodium (Pento) or a mixture of ketamine and xylazine and 2) the feasibility of echocardiographic evaluation of left ventricular (LV) hypertrophy, dilatation, and function in mice with two-kidney, one-clip hypertension or myocardial infarction (MI). Heart rate (HR) in awake mice was 658 ± 9 beats/min; Pento and ketamine plus xylazine reduced HR to 377 ± 11 and 293 ± 19 beats/min, respectively, associated with a significant decrease in shortening fraction (SF), ejection fraction (EF), and cardiac output (CO) and an increase in LV end-diastolic (LVEDD) and end-systolic dimensions (LVESD). Mice with 4 wk of two-kidney, one-clip hypertension had increased LV mass (15.62 ± 0.62 vs. 22.17 ± 1.79 mg) without altered LV dimensions, SF, EF, or CO. Mice studied 4 wk post-MI exhibited obvious LV dilatation and systolic dysfunction, as evidenced by increased LVEDD and LVESD and decreased SF, EF, and CO. Our findings clearly show the adverse impact of anesthesia on basal cardiac function and the difficulty in interpreting data obtained from anesthetized mice. We believe this is the first study to demonstrate the feasibility of using echocardiography to assess cardiovascular function in the nonanesthetized mouse.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sahn, D. J., DeMaria, A., Kisslo, J., & Weyman, A. (1978) · Circulation · doi:10.1161/01.cir.58.6.1072 · Cited by 7,430
Enhanced Myocardial Function in Transgenic Mice Overexpressing the β 2 -Adrenergic Receptor
Milano, C. A., Allen, L. F., Rockman, H. A., Dolber, P. C., McMinn, T. R., Chien, K. R., Johnson, T. D., Bond, R. A., & Lefkowitz, R. J. (1994) · Science · doi:10.1126/science.8160017 · Cited by 740
Liu, Y. H., Yang, X. P., Sharov, V. G., Nass, O., Sabbah, H. N., Peterson, E., & Carretero, O. A. (1997) · Journal of Clinical Investigation · doi:10.1172/jci119360 · Cited by 603
Self-citationA Noninvasive Computerized Tail-Cuff System for Measuring Blood Pressure in Mice
Krege, J. H., Hodgin, J. B., Hagaman, J. R., & Smithies, O. (1995) · Hypertension · doi:10.1161/01.hyp.25.5.1111 · Cited by 587
Transthoracic Echocardiography in Models of Cardiac Disease in the Mouse
Tanaka, N., Dalton, N., Mao, L., Rockman, H. A., Peterson, K. L., Gottshall, K. R., Hunter, J. J., Chien, K. R., & Ross, J. (1996) · Circulation · doi:10.1161/01.cir.94.5.1109 · Cited by 364
Hoit, B. D., Khoury, S. F., Kranias, E. G., Ball, N., & Walsh, R. A. (1995) · Circulation Research · doi:10.1161/01.res.77.3.632 · Cited by 241
Echocardiographic Assessment of Left Ventricular Mass and Systolic Function in Mice
Gardin, J. M., Siri, F. M., Kitsis, R. N., Edwards, J. G., & Leinwand, L. A. (1995) · Circulation Research · doi:10.1161/01.res.76.5.907 · Cited by 220
Two-Kidney, One Clip and One-Kidney, One Clip Hypertension in Mice
Wiesel, P., Mazzolai, L., Nussberger, J., & Pedrazzini, T. (1997) · Hypertension · doi:10.1161/01.hyp.29.4.1025 · Cited by 179
Effect of High Salt Intake in Mutant Mice Lacking Bradykinin-B 2 Receptors
Alfie, M. E., Sigmon, D. H., Pomposiello, S. I., & Carretero, O. A. (1997) · Hypertension · doi:10.1161/01.hyp.29.1.483 · Cited by 154
Self-citationEndothelial Nitric Oxide Gene Knockout Mice
Yang, X.-P., Liu, Y.-H., Shesely, E. G., Bulagannawar, M., Liu, F., & Carretero, O. A. (1999) · Hypertension · doi:10.1161/01.hyp.34.1.24 · Cited by 147
Self-citation
Cited by
Shiojima, I. (2005) · Journal of Clinical Investigation · doi:10.1172/jci24682 · Cited by 939
Bøtker, H. E., Hausenloy, D., Andreadou, I., Antonucci, S., Boengler, K., Davidson, S. M., Deshwal, S., Devaux, Y., Di Lisa, F., Di Sante, M., et al. (2018) · Basic Research in Cardiology · doi:10.1007/s00395-018-0696-8 · Cited by 423
Guidelines for measuring cardiac physiology in mice
Lindsey, M. L., Kassiri, Z., Virag, J. A. I., de Castro Brás, L. E., & Scherrer-Crosbie, M. (2018) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00339.2017 · Cited by 349
Baldeviano, G. C., Barin, J. G., Talor, M. V., Srinivasan, S., Bedja, D., Zheng, D., Gabrielson, K., Iwakura, Y., Rose, N. R., & Cihakova, D. (2010) · Circulation Research · doi:10.1161/circresaha.109.213157 · Cited by 334
Effects of anesthetics on systemic hemodynamics in mice
Janssen, B. J. A., De Celle, T., Debets, J. J. M., Brouns, A. E., Callahan, M. F., & Smith, T. L. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01192.2003 · Cited by 318
Metadata
- Authors
- Yang, X.-P., Liu, Y.-H., Rhaleb, N.-E., Kurihara, N., Kim, H. E., & Carretero, O. A.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1999-11-01
- Volume
- 277
- Issue
- 5
- Pages
- H1967-H1974
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W1825664270
- Cited by
- 365
- References
- 19
- FWCI
- 9.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Echocardiographic assessment of cardiac function in conscious and anesthetized mice. https://app.cochat.ai/papers/10.1152/ajpheart.1999.277.5.h1967
- The paper
- Yang, X.-P., Liu, Y.-H., Rhaleb, N.-E., Kurihara, N., Kim, H. E., & Carretero, O. A. (1999). Echocardiographic assessment of cardiac function in conscious and anesthetized mice. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1999.277.5.h1967
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.