Spontaneous skin temperature oscillations in normal human subjects
The DOI matches its Crossref record.
Abstract
A noninvasive method based on high-resolution measurements and bandpass filtering of spontaneous skin temperature oscillations (approximately 4.0 x 10(-2) degrees C) in the low-frequency range (0.01-0.04 Hz) was investigated in normal human subjects. We hypothesized that the oscillations (temperature variability) originate from vasomotor activity of small arteries and arterioles in subcutaneous tissues. To test this hypothesis, continuous blood pressure waveforms were obtained with the use of an external piezoelectric sensor. The peak-to-peak envelope of the pressure signal (pressure variability) was used as an indicator of vasomotor activity. The variabilities of temperature and pressure were compared using cross-spectral and coherence analysis. The correlation between the peak frequency of the signals was 0.92, and the coherence was greater than 0.9. The signals demonstrated similar changes in spectral energy and peak frequency in response to mental stress. Reproducibility of the temperature variability in individual subjects was verified by repeating measurements 1-12 wk later. The differences in peak frequency were small (0.0155 +/- 0.001 Hz), and in each subject the signals exhibited similar patterns in response to stress. Correlation between spectral characteristics of the signals suggests that temperature variability can be attributed to changes in blood flow resulting from oscillations in vasomotor smooth muscle tone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
“…Hertzman and Roth 1942a, 1942b, 1942c, Hertzman and Flath 1963, Hyndman et al 1971, Peñáz 1978, Ahmed et al 1982, Harness and Marjanovic 1989, Nitzan et al 1996b, 1996a, general thermoregulatory pulse changes in Shusterman et al (1997), Schultz-Ehrenburg and Blazek (2001), Nitzan et al (2001)).”
BackgroundVaschillo, E., Lehrer, P., Rishe, N., & Konstantinov, M. (2002) · Applied Psychophysiology and Biofeedback · doi:10.1023/a:1014587304314 · Cited by 292
Detecting Moments of Stress from Measurements of Wearable Physiological Sensors
Kyriakou, K., Resch, B., Sagl, G., Petutschnig, A., Werner, C., Niederseer, D., Liedlgruber, M., Wilhelm, F., Osborne, T., & Pykett, J. (2019) · Sensors · doi:10.3390/s19173805 · Cited by 239
“The selection of the filters and the associated cut-off frequencies was based on the findings of previous research efforts [11,68,69].”
MethodWearable Devices for Precision Medicine and Health State Monitoring
Jeong, I. C., Bychkov, D., & Searson, P. C. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2871638 · Cited by 155
Allen, J., Frame, J. R., & Murray, A. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/2/312 · Cited by 86
Metadata
- Authors
- Shusterman, V., Anderson, K. P., & Barnea, O.
- Venue
- American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
- Publisher
- American Physiological Society
- Published
- 1997-09-01
- Volume
- 273
- Issue
- 3
- Pages
- R1173-R1181
- ISSN
- 0363-6119 (ISSN-L)
- 1522-1490
- OpenAlex
- W2279260516
- Cited by
- 84
- References
- 0
- FWCI
- 0.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spontaneous skin temperature oscillations in normal human subjects. https://app.cochat.ai/papers/10.1152/ajpregu.1997.273.3.r1173
- The paper
- Shusterman, V., Anderson, K. P., & Barnea, O. (1997). Spontaneous skin temperature oscillations in normal human subjects. American Journal of Physiology-Regulatory, Integrative and Comparative Physiology. https://doi.org/10.1152/ajpregu.1997.273.3.r1173
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.