The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Comparative analysis of NMR and NIRS measurements of intracellular P O 2 in human skeletal muscle
Abstract
1 H NMR has detected both the deoxygenated proximal histidyl N δ H signals of myoglobin (deoxyMb) and deoxygenated Hb (deoxyHb) from human gastrocnemius muscle. Exercising the muscle or pressure cuffing the leg to reduce blood flow elicits the appearance of the deoxyMb signal, which increases in intensity as cellular[Formula: see text] decreases. The deoxyMb signal is detected with a 45-s time resolution and reaches a steady-state level within 5 min of pressure cuffing. Its desaturation kinetics match those observed in the near-infrared spectroscopy (NIRS) experiments, implying that the NIRS signals are actually monitoring Mb desaturation. That interpretation is consistent with the signal intensity and desaturation of the deoxyHb proximal histidyl N δ H signal from the β-subunit at 73 parts per million. The experimental results establish the feasibility and methodology to observe the deoxyMb and Hb signals in skeletal muscle, help clarify the origin of the NIRS signal, and set a stage for continuing study of O 2 regulation in skeletal muscle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Myoglobin O2 desaturation during exercise. Evidence of limited O2 transport.
Richardson, R. S., Noyszewski, E. A., Kendrick, K. F., Leigh, J. S., & Wagner, P. D. (1995) · Journal of Clinical Investigation · doi:10.1172/jci118237 · Cited by 647
Cited by
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Understanding near infrared spectroscopy and its application to skeletal muscle research
Barstow, T. J. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00166.2018 · Cited by 470
Grassi, B., Pogliaghi, S., Rampichini, S., Quaresima, V., Ferrari, M., Marconi, C., & Cerretelli, P. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00695.2002 · Cited by 429
Adipose tissue thickness affects in vivo quantitative near-IR spectroscopy in human skeletal muscle
VAN BEEKVELT, M. C. P., BORGHUIS, M. S., VAN ENGELEN, B. G. M., WEVERS, R. A., & COLIER, W. N. J. M. (2001) · Clinical Science · doi:10.1042/cs1010021 · Cited by 369
DeLorey, D. S., Kowalchuk, J. M., & Paterson, D. H. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00956.2002 · Cited by 369
Metadata
- Authors
- Tran, T.-K., Sailasuta, N., Kreutzer, U., Hurd, R., Chung, Y., Mole, P., Kuno, S., & Jue, T.
- Venue
- American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
- Publisher
- American Physiological Society
- Published
- 1999-06-01
- Volume
- 276
- Issue
- 6
- Pages
- R1682-R1690
- ISSN
- 0363-6119 (ISSN-L)
- 1522-1490
- OpenAlex
- W1913727698
- Cited by
- 175
- References
- 1
- FWCI
- 8.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparative analysis of NMR and NIRS measurements of intracellular P O 2 in human skeletal muscle. https://app.cochat.ai/papers/10.1152/ajpregu.1999.276.6.r1682
- The paper
- Tran, T.-K., Sailasuta, N., Kreutzer, U., Hurd, R., Chung, Y., Mole, P., Kuno, S., & Jue, T. (1999). Comparative analysis of NMR and NIRS measurements of intracellular P O 2 in human skeletal muscle. American Journal of Physiology-Regulatory, Integrative and Comparative Physiology. https://doi.org/10.1152/ajpregu.1999.276.6.r1682
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.