Comparative analysis of NMR and NIRS measurements of intracellular P O 2 in human skeletal muscle
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
1 H NMR has detected both the deoxygenated proximal histidyl N δ H signals of myoglobin (deoxyMb) and deoxygenated Hb (deoxyHb) from human gastrocnemius muscle. Exercising the muscle or pressure cuffing the leg to reduce blood flow elicits the appearance of the deoxyMb signal, which increases in intensity as cellular[Formula: see text] decreases. The deoxyMb signal is detected with a 45-s time resolution and reaches a steady-state level within 5 min of pressure cuffing. Its desaturation kinetics match those observed in the near-infrared spectroscopy (NIRS) experiments, implying that the NIRS signals are actually monitoring Mb desaturation. That interpretation is consistent with the signal intensity and desaturation of the deoxyHb proximal histidyl N δ H signal from the β-subunit at 73 parts per million. The experimental results establish the feasibility and methodology to observe the deoxyMb and Hb signals in skeletal muscle, help clarify the origin of the NIRS signal, and set a stage for continuing study of O 2 regulation in skeletal muscle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899 · cited 2×
“Because O2-ligated heme groups have a greater absorbance at 850 nm than at 760 nm, whereas the corresponding deoxy heme groups have greater absorbance at 760 nm than at 850, the difference signal between 760 and 850 nm can reflect the changes in HbO2-MbO2 saturation on a relative scale (15, 34, 46).”
BackgroundHemoglobin and myoglobin in their reactions with ligands
Antonini, E., & Brunori, M. (1971) · Medical Entomology and Zoology · Cited by 2,671
Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correction
Glover, G. H., & Schneider, E. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180211 · Cited by 687 · cited 1×
“Magnetic field shimming used a three-point Dixon method to improve the field homogeneity, yielding a water line width of ,40 Hz (9, 33).”
MethodMyoglobin O2 desaturation during exercise. Evidence of limited O2 transport.
Richardson, R. S., Noyszewski, E. A., Kendrick, K. F., Leigh, J. S., & Wagner, P. D. (1995) · Journal of Clinical Investigation · doi:10.1172/jci118237 · Cited by 647
Muscle temperature during submaximal exercise in man
Saltin, B., Gagge, A. P., & Stolwijk, J. A. (1968) · Journal of Applied Physiology · doi:10.1152/jappl.1968.25.6.679 · Cited by 305 · cited 3×
“Although the core body temperature is 37°C, the skin temperature can be as low as 27°C, depending on the ambient condition (31).”
BackgroundResultWilson, J. R., Mancini, D. M., McCully, K., Ferraro, N., Lanoce, V, & Chance, B. (1989) · Circulation · doi:10.1161/01.cir.80.6.1668 · Cited by 256 · cited 3×
“Because O2-ligated heme groups have a greater absorbance at 850 nm than at 760 nm, whereas the corresponding deoxy heme groups have greater absorbance at 760 nm than at 850, the difference signal between 760 and 850 nm can reflect the changes in HbO2-MbO2 saturation on a relative scale (15, 34, 46).”
BackgroundMethodSeparate measures of ATP utilization and recovery in human skeletal muscle.
Blei, M. L., Conley, K. E., & Kushmerick, M. J. (1993) · The Journal of Physiology · doi:10.1113/jphysiol.1993.sp019673 · Cited by 256 · cited 1×
“Under the presumed totally desaturated state, the deoxyMb signal intensity represents the 100% deoxygenation point and is the basis for normalizing all the other Mb signals during different exercise/ischemia protocols (2, 4, 25, 29).”
BackgroundSchneider, E., & Glover, G. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180208 · Cited by 221 · cited 1×
“Magnetic field shimming used a three-point Dixon method to improve the field homogeneity, yielding a water line width of ,40 Hz (9, 33).”
MethodEvidence for tissue diffusion limitation of VO2max in normal humans
Roca, J., Hogan, M. C., Story, D., Bebout, D. E., Haab, P., Gonzalez, R., Ueno, O., & Wagner, P. D. (1989) · Journal of Applied Physiology · doi:10.1152/jappl.1989.67.1.291 · Cited by 218 · cited 1×
“Of particular importance is the O2 gradient from the capillary to the mitochondria (11, 30).”
BackgroundSelective excitation in Fourier transform nuclear magnetic resonance
Morris, G. A., & Freeman, R. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.08.031 · Cited by 204
Myoglobin oxygen dissociation by multiwavelength spectroscopy
Schenkman, K. A., Marble, D. R., Burns, D. H., & Feigl, E. O. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.1.86 · Cited by 162 · cited 1×
“39 mmHg (37°C), O2 is still sufficient to maintain the basal energy demand of the muscle tissue, as reflected in the unperturbed 31P spectra (32).”
BackgroundNoninvasive Quantitative Analysis of Blood Oxygenation in Rat Skeletal Muscle
Seiyama, A., Hazeki, O., & Tamura, M. (1988) · The Journal of Biochemistry · doi:10.1093/oxfordjournals.jbchem.a122285 · Cited by 149 · cited 2×
“Because O2-ligated heme groups have a greater absorbance at 850 nm than at 760 nm, whereas the corresponding deoxy heme groups have greater absorbance at 760 nm than at 850, the difference signal between 760 and 850 nm can reflect the changes in HbO2-MbO2 saturation on a relative scale (15, 34, 46).”
BackgroundIn vivo MRS measurement of deoxymyoglobin in human forearms
Wang, Z., Noyszewski, E. A., & Leigh, J. S. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140314 · Cited by 117 · cited 4×
“Yet so far, no studies have reported any Hb signal contamination (25, 29, 43).”
BackgroundResultInfluentialMalleability of skeletal muscle in overcoming limitations: structural elements
Hoppeler, H., & Lindstedt, S. L. (1985) · Journal of Experimental Biology · doi:10.1242/jeb.115.1.355 · Cited by 109
Mancini, D. M., Wilson, J. R., Bolinger, L., Li, H., Kendrick, K., Chance, B., & Leigh, J. S. (1994) · Circulation · doi:10.1161/01.cir.90.1.500 · Cited by 108 · cited 5×
“However, any interpretation based on the normalized steady-state value of the deoxyMb signal intensity must assess the quantitation judiciously (25, 29, 43, 44).”
BackgroundResultInfluentialMyoglobin and hemoglobin rotational diffusion in the cell
Wang, D., Kreutzer, U., Chung, Y., & Jue, T. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78305-x · Cited by 94 · cited 4×
“The observation of the erythrocyte Hb signal is consistent with recent fielddependent relaxation and other erythrocyte Hb studies (3, 6, 7, 10, 19, 24, 42, 43).”
BackgroundResultInfluentialSelf-citationMyoglobin levels in individual human skeletal muscle fibers of different types.
Nemeth, P. M., & Lowry, O. H. (1984) · Journal of Histochemistry & Cytochemistry · doi:10.1177/32.11.6491255 · Cited by 76 · cited 1×
“2 mM metHb as the calibration standard indicates that the Mb signal at the end of the exercisecuff experiment is only 50% desaturated (13, 26, 28, 38, 45).”
MethodMyoglobin in human skeletal muscle
Möller, P., & Sylvén, C. (1981) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365518109090486 · Cited by 68 · cited 1×
“2 mM metHb as the calibration standard indicates that the Mb signal at the end of the exercisecuff experiment is only 50% desaturated (13, 26, 28, 38, 45).”
MethodMuscle O2 transport and O2 dependent control of metabolism
WAGNER, P. D. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199501000-00010 · Cited by 68 · cited 1×
“These mechanisms present a recurring O2 gradient motif, which governs O2 transport to the mitochondria (12, 36, 41).”
Background[18]Proton nuclear magnetic resonance investigation of hemoglobins
Ho, C., & Russu, I. M. (1981) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/0076-6879(81)76128-7 · Cited by 55 · cited 5×
“Such a view is at odds with results from numerous erythrocyte Hb studies (8, 10, 23, 42).”
BackgroundResultInfluentialKreutzer, U., & Jue, T. (1991) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1991.261.6.h2091 · Cited by 52 · cited 2×
“In bufferperfused hearts, these signals appear at distinct chemical shift positions and unquestionably reflect the intracellular PO2 (17, 18).”
BackgroundSelf-citationSylvén, C., Jansson, E., & Böök, K. (1984) · Cardiovascular Research · doi:10.1093/cvr/18.7.443 · Cited by 47 · cited 3×
“5 ppm was then used as a basis to quantitate the observed Mb intensity in exercising gastrocnemius muscle (21, 38).”
BackgroundMethodMyoglobin concentration in single type I and type II muscle fibres in man
Jansson, E., & Sylv�n, C. (1983) · Histochemistry and Cell Biology · doi:10.1007/bf00491118 · Cited by 42
Oxidation/reduction state of cytochrome oxidase during repetitive contractions
STAINSBY, W. N., Brechue, W. F., O’Drobinak, D. M., & Barclay, J. K. (1989) · Journal of Applied Physiology · doi:10.1152/jappl.1989.67.5.2158 · Cited by 41 · cited 1×
“These mechanisms present a recurring O2 gradient motif, which governs O2 transport to the mitochondria (12, 36, 41).”
BackgroundChen, W., Zhang, J. J., Eljgelshoven, M. H. J., Zhang, Y., Zhu, X., Wang, C., Cho, Y., Merkle, H., & Uĝcurbil, K. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380206 · Cited by 39 · cited 1×
“Under the presumed totally desaturated state, the deoxyMb signal intensity represents the 100% deoxygenation point and is the basis for normalizing all the other Mb signals during different exercise/ischemia protocols (2, 4, 25, 29).”
BackgroundTranslational diffusion of hemoglobin in human erythrocytes and hemolysates
Kuchel, P. W., & Chapman, B. E. (1991) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(91)90144-i · Cited by 39 · cited 1×
“The observation of the erythrocyte Hb signal is consistent with recent fielddependent relaxation and other erythrocyte Hb studies (3, 6, 7, 10, 19, 24, 42, 43).”
Result1H nuclear magnetic resonance studies of sarcoplasmic oxygenation in the red cell-perfused rat heart
Jelicks, L. A., & Wittenberg, B. A. (1995) · Biophysical Journal · doi:10.1016/s0006-3495(95)80395-4 · Cited by 36
Short TE phosphorus spectroscopy using a spin‐echo pulse
Lim, K. O., Pauly, J. M., Webb, P. G., Hurd, R. E., & Macovski, A. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320113 · Cited by 34
Self-citation1H-NMR characterization of the human myocardium myoglobin and erythrocyte hemoglobin signais
Kreutzer, U., Chung, Y., Butler, D., & Jue, T. (1993) · Biochimica et Biophysica Acta (BBA) - Protein Structure and Molecular Enzymology · doi:10.1016/0167-4838(93)90192-t · Cited by 34 · cited 6×
“3 ppm at 25°C, the peak at 78 ppm is assigned to Mb at a cellular temperature of ,33°C (5, 16).”
BackgroundResultInfluentialSelf-citationSensitivity ofin vivomrs of the n‐δ proton in proximal histidine of deoxymyoglobin
Wang, Z., Wang, D., Noyszewski, E. A., et al. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910270217 · Cited by 27
Myoglobin signal as an NMR tissue thermometer: implication for hyperthermia treatment of tumors
Chung, Y., & Jue, T. (1994) · Biochimica et Biophysica Acta (BBA) - Molecular Basis of Disease · doi:10.1016/0925-4439(94)90055-8 · Cited by 4 · cited 2×
“1-ppm difference over the physiological temperature range (5, 16).”
BackgroundSelf-citation
Cited by
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Understanding near infrared spectroscopy and its application to skeletal muscle research
Barstow, T. J. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00166.2018 · Cited by 470
Grassi, B., Pogliaghi, S., Rampichini, S., Quaresima, V., Ferrari, M., Marconi, C., & Cerretelli, P. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00695.2002 · Cited by 429
Adipose tissue thickness affects in vivo quantitative near-IR spectroscopy in human skeletal muscle
VAN BEEKVELT, M. C. P., BORGHUIS, M. S., VAN ENGELEN, B. G. M., WEVERS, R. A., & COLIER, W. N. J. M. (2001) · Clinical Science · doi:10.1042/cs1010021 · Cited by 369
DeLorey, D. S., Kowalchuk, J. M., & Paterson, D. H. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00956.2002 · Cited by 369
Metadata
- Authors
- Tran, T.-K., Sailasuta, N., Kreutzer, U., Hurd, R., Chung, Y., Mole, P., Kuno, S., & Jue, T.
- Venue
- American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
- Publisher
- American Physiological Society
- Published
- 1999-06-01
- Volume
- 276
- Issue
- 6
- Pages
- R1682-R1690
- ISSN
- 0363-6119 (ISSN-L)
- 1522-1490
- OpenAlex
- W1913727698
- Cited by
- 175
- References
- 31
- FWCI
- 8.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.