Comparative analysis of NMR and NIRS measurements of intracellular P O 2 in human skeletal muscle
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
1 H NMR has detected both the deoxygenated proximal histidyl N δ H signals of myoglobin (deoxyMb) and deoxygenated Hb (deoxyHb) from human gastrocnemius muscle. Exercising the muscle or pressure cuffing the leg to reduce blood flow elicits the appearance of the deoxyMb signal, which increases in intensity as cellular[Formula: see text] decreases. The deoxyMb signal is detected with a 45-s time resolution and reaches a steady-state level within 5 min of pressure cuffing. Its desaturation kinetics match those observed in the near-infrared spectroscopy (NIRS) experiments, implying that the NIRS signals are actually monitoring Mb desaturation. That interpretation is consistent with the signal intensity and desaturation of the deoxyHb proximal histidyl N δ H signal from the β-subunit at 73 parts per million. The experimental results establish the feasibility and methodology to observe the deoxyMb and Hb signals in skeletal muscle, help clarify the origin of the NIRS signal, and set a stage for continuing study of O 2 regulation in skeletal muscle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899 · cited 2×
“Because O2-ligated heme groups have a greater absorbance at 850 nm than at 760 nm, whereas the corresponding deoxy heme groups have greater absorbance at 760 nm than at 850, the difference signal between 760 and 850 nm can reflect the changes in HbO2-MbO2 saturation on a relative scale (15, 34, 46).”
BackgroundHemoglobin and myoglobin in their reactions with ligands
Antonini, E., & Brunori, M. (1971) · Medical Entomology and Zoology · Cited by 2,671
Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correction
Glover, G. H., & Schneider, E. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180211 · Cited by 687 · cited 1×
“Magnetic field shimming used a three-point Dixon method to improve the field homogeneity, yielding a water line width of ,40 Hz (9, 33).”
MethodMyoglobin O2 desaturation during exercise. Evidence of limited O2 transport.
Richardson, R. S., Noyszewski, E. A., Kendrick, K. F., Leigh, J. S., & Wagner, P. D. (1995) · Journal of Clinical Investigation · doi:10.1172/jci118237 · Cited by 647
Muscle temperature during submaximal exercise in man
Saltin, B., Gagge, A. P., & Stolwijk, J. A. (1968) · Journal of Applied Physiology · doi:10.1152/jappl.1968.25.6.679 · Cited by 305 · cited 3×
“Although the core body temperature is 37°C, the skin temperature can be as low as 27°C, depending on the ambient condition (31).”
BackgroundResultWilson, J. R., Mancini, D. M., McCully, K., Ferraro, N., Lanoce, V, & Chance, B. (1989) · Circulation · doi:10.1161/01.cir.80.6.1668 · Cited by 256 · cited 3×
“Because O2-ligated heme groups have a greater absorbance at 850 nm than at 760 nm, whereas the corresponding deoxy heme groups have greater absorbance at 760 nm than at 850, the difference signal between 760 and 850 nm can reflect the changes in HbO2-MbO2 saturation on a relative scale (15, 34, 46).”
BackgroundMethodSeparate measures of ATP utilization and recovery in human skeletal muscle.
Blei, M. L., Conley, K. E., & Kushmerick, M. J. (1993) · The Journal of Physiology · doi:10.1113/jphysiol.1993.sp019673 · Cited by 256 · cited 1×
“Under the presumed totally desaturated state, the deoxyMb signal intensity represents the 100% deoxygenation point and is the basis for normalizing all the other Mb signals during different exercise/ischemia protocols (2, 4, 25, 29).”
BackgroundSchneider, E., & Glover, G. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180208 · Cited by 221 · cited 1×
“Magnetic field shimming used a three-point Dixon method to improve the field homogeneity, yielding a water line width of ,40 Hz (9, 33).”
MethodEvidence for tissue diffusion limitation of VO2max in normal humans
Roca, J., Hogan, M. C., Story, D., Bebout, D. E., Haab, P., Gonzalez, R., Ueno, O., & Wagner, P. D. (1989) · Journal of Applied Physiology · doi:10.1152/jappl.1989.67.1.291 · Cited by 218 · cited 1×
“Of particular importance is the O2 gradient from the capillary to the mitochondria (11, 30).”
BackgroundSelective excitation in Fourier transform nuclear magnetic resonance
Morris, G. A., & Freeman, R. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.08.031 · Cited by 204
Cited by
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Understanding near infrared spectroscopy and its application to skeletal muscle research
Barstow, T. J. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00166.2018 · Cited by 470
Van Beekvelt, M. C. P., Colier, W. N. J. M., Wevers, R. A., & Van Engelen, B. G. M. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.2.511 · Cited by 430
Grassi, B., Pogliaghi, S., Rampichini, S., Quaresima, V., Ferrari, M., Marconi, C., & Cerretelli, P. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00695.2002 · Cited by 429
Adipose tissue thickness affects in vivo quantitative near-IR spectroscopy in human skeletal muscle
VAN BEEKVELT, M. C. P., BORGHUIS, M. S., VAN ENGELEN, B. G. M., WEVERS, R. A., & COLIER, W. N. J. M. (2001) · Clinical Science · doi:10.1042/cs1010021 · Cited by 369
DeLorey, D. S., Kowalchuk, J. M., & Paterson, D. H. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00956.2002 · Cited by 369
Cerebral blood flow and metabolism during exercise: implications for fatigue
Secher, N. H., Seifert, T., & Van Lieshout, J. J. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00853.2007 · Cited by 344
Grassi, B., & Quaresima, V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091313 · Cited by 345
“54 Several studies have confirmed the presence of a good or very good correlation between the [deoxy(Hb+Mb)] signal, or other tissue oxygenation variables determined by NIRS, and venous O 2 saturation, both in an animal model of isolated muscle in situ 14,72,73 and in exercising humans.”
BackgroundHamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
“overall NIR signals in a study using (1)H-MRS.(53) The differing conclusions from these studies highlight the need for additional studies to clarify not only the issue of the contribution of Mb to the NIR signal, but also the kinetics and the amount of Mb desaturation during exercises under different conditions.”
BackgroundEffects of acute hypoxia on cerebral and muscle oxygenation during incremental exercise
Subudhi, A. W., Dimmen, A. C., & Roach, R. C. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01460.2006 · Cited by 271
Exercise: Kinetic Considerations for Gas Exchange
Rossiter, H. B. (2010) · Comprehensive Physiology · doi:10.1002/cphy.c090010 · Cited by 231
Hamaoka, T., McCully, K. K., Niwayama, M., & Chance, B. (2011) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2011.0298 · Cited by 186
Bangsbo, J., Krustrup, P., González-Alonso, J., & Saltin, B. (2001) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.2001.280.6.e956 · Cited by 179
31P magnetic resonance spectroscopy in skeletal muscle: Experts' consensus recommendations
Meyerspeer, M., Boesch, C., Cameron, D., Dezortová, M., Forbes, S. C., Heerschap, A., Jeneson, J. A. L., Kan, H. E., Kent, J., Layec, G., et al. (2021) · NMR in Biomedicine · doi:10.1002/nbm.4246 · Cited by 176
Ferreira, L. F., Townsend, D. K., Lutjemeier, B. J., & Barstow, T. J. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00907.2004 · Cited by 170
“There is ongoing controversy as to what extent the NIRS signal contains qualitatively significant information from Mb (33, 40, 46).”
BackgroundMethodMyoglobin desaturation with exercise intensity in human gastrocnemius muscle
Molé, P. A., Chung, Y., Tran, T. K., Sailasuta, N., Hurd, R., & Jue, T. (1999) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1999.277.1.r173 · Cited by 164
Self-citationFeldmann, A., Schmitz, R. W., & Erlacher, D. (2019) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.11.115001 · Cited by 203
Chiappa, G. R., Borghi-Silva, A., Ferreira, L. F., Carrascosa, C., Oliveira, C. C., Maia, J., Gimenes, A. C., Queiroga, F., Berton, D., Ferreira, E. M. V., et al. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01364.2007 · Cited by 108
Craig, J. C., Broxterman, R. M., Wilcox, S. L., Chen, C., & Barstow, T. J. (2017) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00207.2017 · Cited by 95
“More recent work using quantitative NIRS instruments and protocols (33, 47) or morphometric modeling (15) has concluded that [Mb] contributes 60–90% to the NIRS signals and is thought to remain constant during exercise and other acute protocols (5) (for a more detailed discussion of this topic, see 15).”
MethodHiroyuki, H., Hamaoka, T., Sako, T., Nishio, S., Kime, R., Murakami, M., & Katsumura, T. (2002) · European Journal of Applied Physiology · doi:10.1007/s00421-002-0644-y · Cited by 69
“The findings suggest that NIRcws signals mostly reflect the haemoglobin in the blood, although there is a contradictory report (Tran et al. 1999).”
BackgroundMyoglobin concentration in skeletal muscle fibers of chronic heart failure patients
Bekedam, M. A., van Beek-Harmsen, B. J., van Mechelen, W., Boonstra, A., & van der Laarse, W. J. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00149.2009 · Cited by 37
Metadata
- Authors
- Tran, T.-K., Sailasuta, N., Kreutzer, U., Hurd, R., Chung, Y., Mole, P., Kuno, S., & Jue, T.
- Venue
- American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
- Publisher
- American Physiological Society
- Published
- 1999-06-01
- Volume
- 276
- Issue
- 6
- Pages
- R1682-R1690
- ISSN
- 0363-6119 (ISSN-L)
- 1522-1490
- OpenAlex
- W1913727698
- Cited by
- 175
- References
- 31
- FWCI
- 8.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.