A simplified method for HPLC determination of creatinine in mouse serum
The DOI matches its Crossref record.
Abstract
Mouse models are frequently used to study renal function. However, mouse serum contains chromagens that interfere with standard picric acid-based assays for serum creatinine. Several alternative methods exist for serum creatinine measurements, including assay by high-performance liquid chromatography (HPLC), but only one has been adapted to mouse serum. Creatinine was measured in serum by acetonitrile deproteinization, followed by isocratic, cation exchange HPLC. The HPLC method was compared with a standard alkaline picrate colorimetric assay, using serum from animals with low-to-moderate renal injury. Acidification of acetonitrile with HCl in the deproteinization step produced variable results, including an extra peak that interfered with integration of the creatinine peak or loss of the creatinine peak. Deproteinizing with acetonitrile alone resulted in a more reliable measurement of serum creatinine, which was validated by a series of known additions of creatinine standard. The HPLC assay was reproducible with coefficients of variation from 1.6 to 5.1%. The picric acid assay overestimated serum creatinine, when directly compared with the HPLC assay. The extent of overestimation, up to sixfold, was greatest at normal (0.1 to 0.2 mg/dl) to moderately elevated (0.5 mg/dl) serum creatinine levels. Mouse serum contains substances that interfere with standard picric acid assays for creatinine. Our new HPLC assay can accurately detect creatinine from 5 μl of mouse serum. These results support the widespread adoption of HPLC to accurately measure serum creatinine in mouse models of renal injury.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mouse Models of Diabetic Nephropathy
Brosius, F. C., Alpers, C. E., Bottinger, E. P., Breyer, M. D., Coffman, T. M., Gurley, S. B., Harris, R. C., Kakoki, M., Kretzler, M., Leiter, E. H., et al. (2009) · Journal of the American Society of Nephrology · doi:10.1681/asn.2009070721 · Cited by 895
Self-citationStromal Cells Protect against Acute Tubular Injury via an Endocrine Effect
Bi, B., Schmitt, R., Israilova, M., Nishio, H., & Cantley, L. G. (2007) · Journal of the American Society of Nephrology · doi:10.1681/asn.2007020140 · Cited by 515
Mouse Models of Diabetic Nephropathy
Breyer, M. D., Bo[Combining Diaeresis]ttinger, E., Brosius, F. C., Coffman, T. M., Harris, R. C., Heilig, C. W., & Sharma, K. (2005) · Journal of the American Society of Nephrology · doi:10.1681/asn.2004080648 · Cited by 467
Self-citationReduced Production of Creatinine Limits Its Use as Marker of Kidney Injury in Sepsis
Doi, K., Yuen, P. S. T., Eisner, C., Hu, X., Leelahavanichkul, A., Schnermann, J. D., & Star, R. A. (2009) · Journal of the American Society of Nephrology · doi:10.1681/asn.2008060617 · Cited by 403
Self-citationEndothelial Nitric Oxide Synthase Deficiency Produces Accelerated Nephropathy in Diabetic Mice
Zhao, H. J., Wang, S., Cheng, H., Zhang, M.-Z., Takahashi, T., Fogo, A. B., Breyer, M. D., & Harris, R. C. (2006) · Journal of the American Society of Nephrology · doi:10.1681/asn.2006070798 · Cited by 359
Daehn, I., Casalena, G., Zhang, T., Shi, S., Fenninger, F., Barasch, N., Yu, L., D’Agati, V., Schlondorff, D., Kriz, W., et al. (2014) · Journal of Clinical Investigation · doi:10.1172/jci71195 · Cited by 294
Bailly, A.-L., Correard, F., Popov, A., Tselikov, G., Chaspoul, F., Appay, R., Al-Kattan, A., Kabashin, A. V., Braguer, D., & Esteve, M.-A. (2019) · Scientific Reports · doi:10.1038/s41598-019-48748-3 · Cited by 283
Urinary exosomal transcription factors, a new class of biomarkers for renal disease
Zhou, H., Cheruvanky, A., Hu, X., Matsumoto, T., Hiramatsu, N., Cho, M. E., Berger, A., Leelahavanichkul, A., Doi, K., Chawla, L. S., et al. (2008) · Kidney International · doi:10.1038/ki.2008.206 · Cited by 276
Self-citationSimvastatin improves sepsis-induced mortality and acute kidney injury via renal vascular effects.
Yasuda, H., Yuen, P. S. T., Hu, X., Zhou, H., & Star, R. A. (2006) · Kidney International · doi:10.1038/sj.ki.5000300 · Cited by 209
“Mice were sacrified at indicated times for measurement of serum BUN (A) and creatinine by HPLC method (B).”
Self-citationLeelahavanichkul, A., Yan, Q., Hu, X., Eisner, C., Huang, Y., Chen, R., Mizel, D., Zhou, H., Wright, E. C., Kopp, J. B., et al. (2010) · Kidney International · doi:10.1038/ki.2010.287 · Cited by 167
Self-citationCorpe, C. P., Tu, H., Eck, P., Wang, J., Faulhaber-Walter, R., Schnermann, J., Margolis, S., Padayatty, S., Sun, H., Wang, Y., et al. (2010) · Journal of Clinical Investigation · doi:10.1172/jci39191 · Cited by 162
BAMBI Elimination Enhances Alternative TGF-β Signaling and Glomerular Dysfunction in Diabetic Mice
Fan, Y., Li, X., Xiao, W., Fu, J., Harris, R. C., Lindenmeyer, M., Cohen, C. D., Guillot, N., Baron, M. H., Wang, N., et al. (2015) · Diabetes · doi:10.2337/db14-1397 · Cited by 57
Metadata
- Authors
- Yuen, P. S. T., Dunn, S. R., Miyaji, T., Yasuda, H., Sharma, K., & Star, R. A.
- Venue
- American Journal of Physiology-Renal Physiology
- Publisher
- American Physiological Society
- Published
- 2004-06
- Volume
- 286
- Issue
- 6
- Pages
- F1116-F1119
- ISSN
- 1522-1466 (ISSN-L)
- 1931-857X
- OpenAlex
- W2002200543
- Cited by
- 139
- References
- 0
- FWCI
- 4.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.