Six volunteers raised their rectal temperatures to 104℉ by 40–50 minutes' work at 93℉ wet-bulb temperature. The rates of fall in rectal temperatures were studied during cooling by six different methods. The most rapid method of cooling occurred when subjects sat at rest in an air condition of 90℉ dry bulb and 87℉ wet bulb and evaporative cooling was accelerated by wetting the body surface continuously for 1 hour; no significant difference in cooling was observed between airflows of 120 ft/min. and a jet of compressed air held 1–3 ft from subjects. Merely seating individuals in air conditions of 70℉ with 20% relative humidity in still air was almost as effective. Immersion in cold water and sitting in air conditions of 90℉ (D.B.) and 87℉ (W.B.) without aiding evaporative cooling are significantly less effective than the foregoing methods. Resting subjects at 97℉ (D.B.), 93℉ (W.B.) and 120 ft/min. air velocity results in very slow cooling. ‘Afterdrop’ in rectal temperature after ice-cold water cooling may be associated with severe circulatory shock. Oral temperatures are a less reliable index of core temperature than rectal. Submitted on February 16, 1959
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bouchama, A., & Knochel, J. P. (2002) · New England Journal of Medicine · doi:10.1056/nejmra011089 · Cited by 1,898
National athletic trainers’ association position statement: Exertional heat illnesses
Casa, D. J., DeMartini, J. K., Bergeron, M. F., Csillan, D., Eichner, E. R., Lopez, R. M., Ferrara, M. S., Miller, K. C., O'Connor, F., Sawka, M. N., et al. (2015) · Journal of Athletic Training · doi:10.4085/1062-6050-50.9.07 · Cited by 975
Classic and exertional heatstroke
Bouchama, A., Abuyassin, B., Lehe, C., Laitano, O., Jay, O., O’Connor, F. G., & Leon, L. R. (2022) · Nature Reviews Disease Primers · doi:10.1038/s41572-021-00334-6 · Cited by 444
Leon, L. R., & Bouchama, A. (2015) · Comprehensive Physiology · doi:10.1002/cphy.c140017 · Cited by 403
Cold Water Immersion: The Gold Standard for Exertional Heatstroke Treatment
Casa, D. J., McDermott, B. P., Lee, E. C., Yeargin, S. W., Armstrong, L. E., & Maresh, C. M. (2007) · Exercise and Sport Sciences Reviews · doi:10.1097/jes.0b013e3180a02bec · Cited by 336
Effect of water temperature on cooling efficiency during hyperthermia in humans
Proulx, C. I., Ducharme, M. B., & Kenny, G. P. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00541.2002 · Cited by 256
Acute Whole-Body Cooling for Exercise-Induced Hyperthermia: A Systematic Review
McDermott, B. P., Casa, D. J., Ganio, M. S., Lopez, R. M., Yeargin, S. W., Armstrong, L. E., & Maresh, C. M. (2009) · Journal of Athletic Training · doi:10.4085/1062-6050-44.1.84 · Cited by 244
Exertional Heat Stroke: New Concepts Regarding Cause and Care
Casa, D. J., Armstrong, L. E., Kenny, G. P., O’Connor, F. G., & Huggins, R. A. (2012) · Current Sports Medicine Reports · doi:10.1249/jsr.0b013e31825615cc · Cited by 227
Cooling and hemodynamic management in heatstroke: practical recommendations
Bouchama, A., Dehbi, M., & Chaves-Carballo, E. (2007) · Critical Care · doi:10.1186/cc5910 · Cited by 222
“surface while continually fanning [16-30].”
BackgroundMisset, B., De Jonghe, B., Bastuji-Garin, S., Gattolliat, O., Boughrara, E., Annane, D., Hausfater, P., Garrouste-Orgeas, M., & Carlet, J. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000206469.33615.02 · Cited by 178
“Cooling by evaporation has been shown to be more efficient than cooling by conduction in animal models and healthy volunteers (28).”
BackgroundSoukup, J., Zauner, A., Doppenberg, E. M. R., Menzel, M., Gilman, C., Young, H. F., & Bullock, R. (2002) · Journal of Neurotrauma · doi:10.1089/089771502753754046 · Cited by 165
“A few studies have noted that this cooling method is associated with greater temperature fluctuations, rebound hypothermia, and shivering (Atkins, 1983; O’Donnell et al., 1997; Wyndham et al., 1959).”
Preparing Alberto Salazar for the Heat of the 1984 Olympic Marathon
Armstrong, L. E., Hubbard, R. W., Jones, B. H., & Daniels, J. T. (1986) · The Physician and Sportsmedicine · doi:10.1080/00913847.1986.11709011 · Cited by 111
Metadata
- Authors
- Wyndham, C. H., Strydom, N. B., Cooke, H. M., Maritz, J. S., Morrison, J. F., Fleming, P. W., & Ward, J. S.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1959-09-01
- Volume
- 14
- Issue
- 5
- Pages
- 771-776
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2277492845
- Cited by
- 127
- References
- 0
- FWCI
- 0.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.