Respiratory sinus arrhythmia: laws derived from computer simulation
The DOI matches its Crossref record.
Abstract
Dynamic mathematical relations describing respiratory sinus arrhythmia were derived through analogue computer simulation. If a signal proportional to thorax circumference is fed into the analogue computer, it calculates with differential equations the complex heart rate changes in real time and records them along with those of the real heart. Close correspondence of the predicted and actual changes of heart rate for a wide variety of modes of breathing, and for different individuals, proves the validity of the nonlinear differential equations describing the phenomenon. The respiratory effects are shown to be caused by two separate reflexes each producing biphasic heart rate transients in the same directions. The observed effects are the result of superposition of those transients. Previous paradoxical results in attempting to relate heart rate to respiration on a steady-state, nondynamic basis are thus explained. The laws indicate that stretch receptors and not hemodynamic or central nervous factors initiate the changes in heart rate. The analysis also allows heart rate effects of exercise and emotional stresses to be more precisely perceived, as clearly separated from respiratory effects. Submitted on June 16, 1959
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Grossman, P., & Taylor, E. W. (2007) · Biological Psychology · doi:10.1016/j.biopsycho.2005.11.014 · Cited by 1,133
Respiratory sinus arrhythmia in humans: how breathing pattern modulates heart rate
Hirsch, J. A., & Bishop, B. (1981) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1981.241.4.h620 · Cited by 1,105
“Other investigators have studied the separate effects of breathing frequency, tidal volume, and static lung volume on the RSA amplitude (1,24,26,28,32) and wave form (5, 33) or phase angle (1, 20, 21, 24, 33).”
BackgroundTransfer function analysis of the circulation: unique insights into cardiovascular regulation
Saul, J. P., Berger, R. D., Albrecht, P., Stein, S. P., Chen, M. H., & Cohen, R. J. (1991) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1991.261.4.h1231 · Cited by 729
Respiration, Stress, and Cardiovascular Function
Grossman, P. (1983) · Psychophysiology · doi:10.1111/j.1469-8986.1983.tb02156.x · Cited by 386
A comparison of three quantification methods for estimation of respiratory sinus arrhythmia.
Grossman, P., van Beek, J., & Wientjes, C. (1990) · Psychophysiology · doi:10.1111/j.1469-8986.1990.tb03198.x · Cited by 381
Metadata
- Authors
- Clynes, M.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1960-09-01
- Volume
- 15
- Issue
- 5
- Pages
- 863-874
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1833347084
- Cited by
- 93
- References
- 0
- FWCI
- 2.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Respiratory sinus arrhythmia: laws derived from computer simulation. https://app.cochat.ai/papers/10.1152/jappl.1960.15.5.863
- The paper
- Clynes, M. (1960). Respiratory sinus arrhythmia: laws derived from computer simulation. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1960.15.5.863
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.