CoChat

Relationship between forearm tremor and the biceps electromyogram

Fox, J. R., Randall, J. E. · 1970 · Journal of Applied Physiology
Cited by 95

The DOI matches its Crossref record.

Abstract

forearm tremor and the biceps electromyogram. J. Appl. Physiol. 29 (I): 103- 108. 1970.-Forearm acceleration and the biceps electro-myogram (skin electrodes) were measured in six normal human subjects for weights ranging from 0 to 10 lb. applied at the wrist. Power spectra of 25.6-set acceleration records each contained a singIe narrow peak with an average frequency for the six subjects of 3.3 1 Hz. Adding weight systematically decreased the frequency of the peak. The cCdemodulated ” EMG was derived by rectifying and low-pass filtering (cutoff frequency at 35 Hz) the biceps EMG. Power spectra of the demodulated EMG contained a single narrow peak at about 12 Hz that systematically increased in frequency for increased applied weight. Cross-correlation analysis revealed no significant coherence at the tremor frequency between acceleration and the low-pass-filtered EMG (cutoff at 35 Hz) or the demodulated EMG. This data supports the hy-

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1970.29.1.103

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 95

Metadata

Authors
Fox, J. R., & Randall, J. E.
Venue
Journal of Applied Physiology
Published
1970-07-01
Volume
29
Issue
1
Pages
103-108
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2176873773
Cited by
95
References
0
FWCI
2.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Relationship between forearm tremor and the biceps electromyogram. https://app.cochat.ai/papers/10.1152/jappl.1970.29.1.103
The paper
Fox, J. R., & Randall, J. E. (1970). Relationship between forearm tremor and the biceps electromyogram. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1970.29.1.103

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.