Oxygen intake and cardiac output during maximal treadmill and bicycle exercise
The DOI matches its Crossref record.
Abstract
Oxygen intake and cardiac output were measured in 17 male students, aged 18–23 years, during maximal treadmill and bicycle ergometer exercise with stepwise incremental loading and constant loading. The average values of oxygen intake and cardiac output during treadmill exercise were higher than during bicycle ergometer exercise, either with incremental loading or constant loading. These differences were statistically significant (P < 0.001–0.01). No statistically significant differences are found in stroke volume, whereas significant differences were seen in maximum heart rate between all four different modes of exercise. Arteriovenous oxygen differences were higher during treadmill exercise than during bicycle ergometer exercise. It is suggested that lower maximum oxygen intake during bicycle ergometer exercise is related to the lower maximum cardiac output and lower arteriovenous oxygen differences as compared with treadmill exercise. maximum oxygen intake; maximum cardiac output; maximum heart rate; stroke volume during maximal exercise; arteriovenous oxygen difference during maximal exercise; comparison of treadmill and bicycle exercise
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Balady, G. J., Arena, R., Sietsema, K., Myers, J., Coke, L., Fletcher, G. F., Forman, D., Franklin, B., Guazzi, M., Gulati, M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181e52e69 · Cited by 1,964
Fletcher, G. F., Balady, G. J., Amsterdam, E. A., Chaitman, B., Eckel, R., Fleg, J., Froelicher, V. F., Leon, A. S., Piña, I. L., Rodney, R., et al. (2001) · Circulation · doi:10.1161/hc3901.095960 · Cited by 1,923
Arena, R., Myers, J., Williams, M. A., Gulati, M., Kligfield, P., Balady, G. J., Collins, E., & Fletcher, G. (2007) · Circulation · doi:10.1161/circulationaha.106.184461 · Cited by 727
Comparison of the ramp versus standard exercise protocols
Myers, J., Buchanan, N., Walsh, D., Kraemer, M., McAuley, P., Hamilton-Wessler, M., & Froelicher, V. F. (1991) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(10)80144-5 · Cited by 536
Fleg, J. L., Piña, I. L., Balady, G. J., Chaitman, B. R., Fletcher, B., Lavie, C., Limacher, M. C., Stein, R. A., Williams, M., & Bazzarre, T. (2000) · Circulation · doi:10.1161/01.cir.102.13.1591 · Cited by 287
A comparison of methods of predicting maximum oxygen uptake.
Grant, S., Corbett, K., Amjad, A. M., Wilson, J., & Aitchison, T. (1995) · British Journal of Sports Medicine · doi:10.1136/bjsm.29.3.147 · Cited by 202
Fall in skin temperature of exercising man.
Torii, M., Yamasaki, M., Sasaki, T., & Nakayama, H. (1992) · British Journal of Sports Medicine · doi:10.1136/bjsm.26.1.29 · Cited by 145
Metadata
- Authors
- Miyamara, M., & Honda, Y.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1972-02-01
- Volume
- 32
- Issue
- 2
- Pages
- 185-188
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2415129798
- Cited by
- 64
- References
- 0
- FWCI
- 4.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.