CoChat

An ultrasonic pulsed Doppler system for measuring blood flow in small vessels.

Hartley, C J, Cole, J S · 1974 · Journal of Applied Physiology
Cited by 354

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

tem for measuring blood Jaw in small vessels. J. Appl. Physiol. 37 (4): 626-629. 1974.-A new system has been developed for the measurement of blood flow in small vessels, l-5 mm in diameter. The transducer may be used in both acute studies where the vessel is directly exposed and in chronic studies where the transducer is surgically implanted around the vessel and flow measurements re-corded after the experimental animal has fully recovered from the surgical procedure. A ZO-MHz directional pulsed Doppler ultra-sonic flowmeter is used to drive a single piezoelectrical crystal, mounted on a small lightweight cuff-type probe. A unique trans-former coupling system allows the chronic implantation of flow probes leaving no wires protruding through the skin. Initial evaluation of the system on coronary arteries in acute and chronic dog studies shows good stability and linearity. coronary artery flow; chronic flow probe; flowmeter; laminar

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1974.37.4.626

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Hartley, C. J., & Cole, J. S.
Venue
Journal of Applied Physiology
Published
1974-10
Volume
37
Issue
4
Pages
626-629
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2343564213
Cited by
354
References
1
FWCI
4.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.