An automated system for assessing metabolic and respiratory function during exercise
The DOI matches its Crossref record.
Abstract
This paper provides a brief description of a new, totally automated system for assessing metabolic and respiratory function during exercise. This system was evaluated simultaneously against two established systems, one a computer-based system and the other a semiautomated system, to determine its validity over a wide range of metabolic levels, i.e., less than 2 to greater than 16 mets. A total of 112 males and females, 12–65 yr of age, performed either arm or leg exercises on a bicycle ergometer or treadmill, starting at approximately 2 mets and progressing by approximately 1 met/min to the point of volitional fatigue. Respiratory and metabolic assessments were made each minute during the entire exercise bout. Comparisons across the three systems demonstrated remarkable agreement, particularly when all potential sources of error for each system are considered. Although several statistically significant differences between two of the systems were noted at the lowest work levels, the difference in VO2 between any two systems never exceeded 1.1 ml/kg-min.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Interference of strength development by simultaneously training for strength and endurance.
Hickson, R. C. (1980) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00421333 · Cited by 753
Measurement of energy expenditure
Levine, J. A. (2005) · Public Health Nutrition · doi:10.1079/phn2005800 · Cited by 401
The acute splanchnic and peripheral tissue metabolic response to endotoxin in humans.
Fong, Y. M., Marano, M. A., Moldawer, L. L., Wei, H., Calvano, S. E., Kenney, J. S., Allison, A. C., Cerami, A., Shires, G. T., & Lowry, S. F. (1990) · Journal of Clinical Investigation · doi:10.1172/jci114651 · Cited by 364
Incompatibility of endurance- and strength-training modes of exercise
Dudley, G. A., & Djamil, R. (1985) · Journal of Applied Physiology · doi:10.1152/jappl.1985.59.5.1446 · Cited by 324
Validity of inspiratory and expiratory methods of measuring gas exchange with a computerized system
Bassett, D. R., Howley, E. T., Thompson, D. L., King, G. A., Strath, S. J., McLaughlin, J. E., & Parr, B. B. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.1.218 · Cited by 118
Metadata
- Authors
- Wilmore, J. H., Davis, J. A., & Norton, A. C.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1976-04-01
- Volume
- 40
- Issue
- 4
- Pages
- 619-624
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2160757426
- Cited by
- 111
- References
- 0
- FWCI
- 4.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An automated system for assessing metabolic and respiratory function during exercise. https://app.cochat.ai/papers/10.1152/jappl.1976.40.4.619
- The paper
- Wilmore, J. H., Davis, J. A., & Norton, A. C. (1976). An automated system for assessing metabolic and respiratory function during exercise. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1976.40.4.619
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.