Abstract

Serial distribution of airway properties determines in part the response of the lung to high frequency oscillations. We measured the response of excised dog lungs and lobes between 156 and 10,000 Hz and determined the area-distance function of the acoustically equivalent structure having rigid walls, regular branching, and negligible internal losses. The utility of this techique was tested by determining the effects of air trapping, removal of pleura from a dried lung, central airway smooth muscle tone. A strong correlation was found between relative changes in equivalent acoustic area and relative area changes measured radiographically in individual airways at corresponding distances. We conclude that despite departures of the properties of the real lung from the characteristics of the acoustically equivalent structure, changes in the area-distance function computed by this technique provide reasonable estimates of the magnitude and serial distribution of actual changes in airway cross-sectional area.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1977.43.3.523

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Jackson, A. C., Butler, J. P., Millet, E. J., Hoppin, F. G., & Dawson, S. V.
Venue
Journal of Applied Physiology
Published
1977-09-01
Volume
43
Issue
3
Pages
523-536
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W1925132035
Cited by
237
References
0
FWCI
3.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.