CoChat

Acoustic rhinometry in the evaluation of nasal obstruction

Roithmann, Renato, Cole, Philip, Chapnik, Jerry, Shpirer, Isaac, Hoffstein, Victor, Zamel, Noe · 1995 · The Laryngoscope
Cited by 161

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Acoustic rhinometry (AR) is a recently developed objective technique for assessment of geometry of the nasal cavity. The technique is based on the analysis of sound waves reflected from the nasal cavities. It measures cross‐sectional areas and nasal volume (NV). To obtain dependable assessments of nasal resistance by rhinomanometry or cross‐sectional area measurements by AR, it is essential that the structural relations of the compliant vestibular region remain undisturbed by the measuring apparatus. The use of nozzles in making these measurements carries a great risk of direct distortion of the nasal valve. We used a nasal adapter that does not invade the nasal cavity and a chin support that stabilizes the head. In 51 healthy nasal cavities, the average minimum cross‐sectional area (MCA) was 0.62 cm 2 at 2.35 cm from the nostril and 0.67 cm 2 at 2 cm from the nostril, respectively, before and after topical decongestion of the nasal mucosa. The MCA and NV findings in this group were significantly higher than MCA and NV (P<0.001) in people with structural or mucosal abnormalities before mucosal decongestion. After mucosal decongestion, the MCA and NV were significantly higher in healthy nasal cavities than in nasal cavities with structural abnormalities (P<0.001) but were not higher than nasal cavities with mucosal abnormalities (MCA, P = 0.05; NV, P = 0.06). A nozzle was applied in 20 healthy nasal cavities after mucosal decongestion, and a significantly higher MCA was found compared to measurements made with the nasal adapter (P = 0.02). We conclude that the nasal adapter, which does not invade the nasal cavities, avoids the distortion of the nasal valve and gives more accurate results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1288/00005537-199503000-00010

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 161

Metadata

Authors
Roithmann, R., Cole, P., Chapnik, J., Shpirer, I., Hoffstein, V., & Zamel, N.
Venue
The Laryngoscope
Publisher
Wiley
Published
1995-03
Volume
105
Issue
3
Pages
275-281
ISSN
  • 0023-852X (ISSN-L)
  • 1531-4995
OpenAlex
W2023616982
Cited by
161
References
1
FWCI
9.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Acoustic rhinometry in the evaluation of nasal obstruction. https://app.cochat.ai/papers/10.1288/00005537-199503000-00010
The paper
Roithmann, R., Cole, P., Chapnik, J., Shpirer, I., Hoffstein, V., & Zamel, N. (1995). Acoustic rhinometry in the evaluation of nasal obstruction. The Laryngoscope. https://doi.org/10.1288/00005537-199503000-00010

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.