Cardiovascular effects of positive end-expiratory pressure in dogs
The DOI matches its Crossref record.
Abstract
Our purpose was to reexamine the relationship of the fall in cardiac output and blood pressure which occurs during positive end-expiratory pressure (PEEP) to changes in transmural right atrial and left atrial filling pressures. Closed-chest dogs, half with pulmonary edema, were studied during spontaneous breathing and inspiratory positive-pressure breathing (IPPB) with 0–15 cmH2O PEEP. Mean esophageal pressure accurately reflected changes in pericardial pressure and was used to estimate extracardiac pressure. We found that cardiac output fell approximately 50% and blood pressure fell 20% during 15 cmH2OPEEP in spite of well maintained transmural right atrial and left atrial (or pulmonary artery wedge) pressures suggesting a primary or reflex depression of atrial or ventricular function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Afferent vagal C fibre innervation of the lungs and airways and its functional significance
Coleridge, J. C. G., & Coleridge, H. M. (1984) · Reviews of Physiology, Biochemistry and Pharmacology · doi:10.1007/bfb0027715 · Cited by 712
The Application of Esophageal Pressure Measurement in Patients with Respiratory Failure
Akoumianaki, E., Maggiore, S. M., Valenza, F., Bellani, G., Jubran, A., Loring, S. H., Pelosi, P., Talmor, D., Grasso, S., Chiumello, D., et al. (2014) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201312-2193ci · Cited by 635
Naughton, M. T., Rahman, M. A., Hara, K., Floras, J. S., & Bradley, T. D. (1995) · Circulation · doi:10.1161/01.cir.91.6.1725 · Cited by 466
Boulain, T., Achard, J.-M., Teboul, J.-L., Richard, C., Perrotin, D., & Ginies, G. (2002) · Chest · doi:10.1378/chest.121.4.1245 · Cited by 351
Dantzker, D. R., Lynch, J. P., & Weg, J. G. (1980) · Chest · doi:10.1378/chest.77.5.636 · Cited by 285
Ranieri, V. M., Giuliani, R., Cinnella, G., Pesce, C., Brienza, N., Lippolito, E., Pomo, V., Fiore, T., Gottfried, S. B., & Brienza, A. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/147.1.5 · Cited by 235
The right ventricle: interaction with the pulmonary circulation
Pinsky, M. R. (2016) · Critical Care · doi:10.1186/s13054-016-1440-0 · Cited by 212
“both spontaneous [35] and positive pressure-induced hyperinflation [36–38] cause similar compressive effects”
BackgroundBlood Pressure Measurements in the Newborn
Nuntnarumit, P., Yang, W., & Bada-Ellzey, H. S. (1999) · Clinics in Perinatology · doi:10.1016/s0095-5108(18)30030-7 · Cited by 191
Influence of expiratory loading and hyperinflation on cardiac output during exercise
Stark-Leyva, K. N., Beck, K. C., & Johnson, B. D. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00756.2003 · Cited by 118
“A positive shift in Pe will raise right atrial pressure and central venous pressure and subsequently reduce the gradient for venous return; however, such a pressure change will also reduce left ventricular transmural pressure and potentially reduce afterload (6, 28).”
Background
Metadata
- Authors
- Cassidy, S. S., Robertson, C. H., Pierce, A. K., & Johnson, R. L.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1978-05-01
- Volume
- 44
- Issue
- 5
- Pages
- 743-750
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1909967826
- Cited by
- 202
- References
- 0
- FWCI
- 16.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.