Effects of temperature, relative humidity, and mode of breathing on canine airway secretions
The DOI matches its Crossref record.
Abstract
Airway secretions were collected from the upper trachea of eight healthy nosebreathing mongrel dogs under general anesthesia, and the electrolytes and osmolality of these secretions were determined. Compared to plasma, secretions contained 15% higher Na+ and 33% higher Cl-, were 18% higher in osmolality, but had a lower Na+/Cl- throughout the 6-h experiments. When six nose-breathing dogs were exposed to air at 28.5 degrees C and 95% relative humidity, secretion osmolality became lower, but Na+/Cl- remained unchanged. In four other dogs, secretions approached the osmolality of plasma when inspired air was at 36.4 degrees C and 100% relative humidity. These secretions contained 22% higher Cl- and a lower Na+/Cl- than plasma. The differences between airway secretions and interstitial fluid suggest that secretions are formed by active Cl- transport. In another four dogs, secretion osmolality was higher with mouth breathing than breathing through the nose. Inasmuch as humidified and warmed air lowered and mouth breathing raised the osmolality of airway secretions, we postulate that the hyperosmolality of secretions results from water loss from the airway surface during conditioning of inspired air.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Micro- and macrorheology of mucus
Lai, S. K., Wang, Y.-Y., Wirtz, D., & Hanes, J. (2009) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.09.012 · Cited by 1,223
Human airway ion transport. Part one.
Boucher, R. C. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.150.1.8025763 · Cited by 444
Expression and Localization of Epithelial Aquaporins in the Adult Human Lung
Kreda, S. M., Gynn, M. C., Fenstermacher, D. A., Boucher, R. C., & Gabriel, S. E. (2001) · American Journal of Respiratory Cell and Molecular Biology · doi:10.1165/ajrcmb.24.3.4367 · Cited by 258
A flexible and wearable glucose sensor based on functional polymers with Soft-MEMS techniques
Kudo, H., Sawada, T., Kazawa, E., Yoshida, H., Iwasaki, Y., & Mitsubayashi, K. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.05.006 · Cited by 255
Role of the physiochemical properties of mucus in the protection of the respiratory epithelium
Girod, S., Zahm, J., Plotkowski, C., Beck, G., & Puchelle, E. (1992) · European Respiratory Journal · doi:10.1183/09031936.93.05040477 · Cited by 220
Interaction between hyperosmolar and IgE-mediated histamine release from basophils and mast cells.
Eggleston, P. A., Kagey‐Sobotka, A., Schleimer, R. P., & Lichtenstein, L. M. (1984) · PubMed · doi:10.1164/arrd.1984.130.1.86 · Cited by 179
A flexible and wearable biosensor for tear glucose measurement
Iguchi, S., Kudo, H., Saito, T., Ogawa, M., Saito, H., Otsuka, K., Funakubo, A., & Mitsubayashi, K. (2007) · Biomedical Microdevices · doi:10.1007/s10544-007-9073-3 · Cited by 173
Molecular insights into the physiology of the ‘thin film’ of airway surface liquid
Boucher, R. C. (1999) · The Journal of Physiology · doi:10.1111/j.1469-7793.1999.0631u.x · Cited by 173
“In vivo studies of ASL composition in dogs demonstrated that transient increases in tracheal ASL osmolarity were generated by exposure to poorly conditioned air, as measured by both nylon screen and filter paper sampling techniques (Man et al. 1979; Boucher et al. 1981).”
MethodCavitas Sensors: Contact Lens Type Sensors & Mouthguard Sensors
Mitsubayashi, K., & Arakawa, T. (2016) · Electroanalysis · doi:10.1002/elan.201600083 · Cited by 71
Metadata
- Authors
- Man, S. F., Adams, G. K., & Proctor, D. F.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1979-02-01
- Volume
- 46
- Issue
- 2
- Pages
- 205-210
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1847873908
- Cited by
- 102
- References
- 0
- FWCI
- 0.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.