Cited by 173Electrochemical sensors and biosensorsAnalytical Chemistry and SensorsEnzyme Catalysis and Immobilization

A flexible and wearable biosensor for tear glucose measurement

Iguchi, Shigehito, Kudo, Hiroyuki, Saito, Takao, Ogawa, Mitsuhiro, Saito, Hirokazu, Otsuka, Kimio, Funakubo, Akio, Mitsubayashi, Kohji·2007·Biomedical Microdevices

Abstract

A flexible and wearable amperometoric glucose sensor was fabricated and tested. Also, the sensor was utilized to tear glucose monitoring. The sensor was constructed by immobilizing GOD onto a flexible oxygen electrode (Pt working electrode and Ag/AgCl counter/reference electrode), which was fabricated using "Soft-MEMS" techniques onto a functional polymer membrane. In purpose of bioinstrumentation, adhesive agents were not used for constructing the flexible biosensor. Linear relationship between glucose concentration and output current was obtained in a range of 0.025-1.475 mmol/l, with a correlation coefficient of 0.998. Current dependences on pH and temperature were also evaluated. The current was largest at pH 7.0 and the current increased when temperature increased. This indicates that the output current depends on enzyme activity. Based on the basic characteristics investigation, the glucose sensor was applied to measurement of glucose in tear fluids on an eye site of a Japan white rabbit. The change of tear glucose level induced by oral-administration of glucose was monitored as a current change of the sensor attached on the eye site. In this investigation, the tear glucose level varied from 0.16 to 0.46 mmol/l. Although there was a delay of several tens of minutes towards blood sugar level, it is considered to be possible that non-invasive continuous glucose monitoring can be realized using the flexible biosensor.

Integrity signals

Registry

Crossref · 10.1007/s10544-007-9073-3

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Wearable tear biosensors have been used for continuous glucose monitoring since 2007 and later for lactate sensing since 2012.

    “Wearable tear biosensors have been used for continuous glucose monitoring since 2007 [147,148,149], and later for lactate sensing since 2012 [150].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Iguchi, S., Kudo, H., Saito, T., Ogawa, M., Saito, H., Otsuka, K., Funakubo, A., & Mitsubayashi, K.
Affiliations
  • Tokai University (JP)
  • Tokyo Medical and Dental University (JP)
  • Tokyo Denki University (JP)
Corresponding author
Mitsubayashi, Kohji
Venue
Biomedical Microdevices
Published
2007-05-23
Volume
9
Issue
4
Pages
603-609
ISSN
  • 1387-2176 (ISSN-L)
  • 1572-8781
OpenAlex
W2059573963
Cited by
173
References
20
Citations by year
2026: 2 · 2025: 7 · 2024: 16 · 2023: 11 · 2022: 17 · 2021: 16 · 2020: 16 · 2019: 17 · 2018: 12 · 2017: 13 · 2016: 8 · 2015: 6 · 2014: 5 · 2013: 3 · 2012: 2
FWCI
5.35
Type
journal article
Language
en
Open access
closed
Locations
  • Biomedical Microdevices (publishedVersion)
  • PubMed (publishedVersion)
  • Institutional Repositories DataBase (IRDB) (submittedVersion)
Funders
  • Nakatani Foundation for Advancement of Measuring Technologies in Biomedical Engineering
  • Japan Society for the Promotion of Science
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Enzyme Catalysis and Immobilization
Keywords
wearable biosensors, flexible biosensors, amperometric glucose sensor, tear glucose, glucose oxidase immobilization, oxygen electrode, non-invasive glucose monitoring, continuous glucose monitoring, rabbits
MeSH terms
Animals, Electrochemistry, Female, Glucose, Hydrogen-Ion Concentration, Rabbits, Tears, Biosensing Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review