Pulmonary mechanics and gas exchange in seated normal men with chest restriction
The DOI matches its Crossref record.
Abstract
Lung volumes, static pressure-volume curves, maximal expiratory flow-volume curves, right-to-left intrapulmonary shunts (Qs/Qt), and distributions of ventilation and perfusion relative to the alveolar ventilation and perfusion ration (VA/Q) were determined in seated normal men before chest strapping while breathing air (Cair) and during chest strapping while breathing air (Sair) or 100% oxygen (So2). With Sair and So2, mean vital capacity was reduced by 44% from control. Elastic recoil pressure [Pst(L)] of the lung at 50% control total lung capacity (TLC) increased significantly (P less than 0.05) from 4.64 +/- 0.39 cmH2O (mean +/- SE) to 7.00 +/- 0.47 cmH2O with Sair and to 7.24 +/- 0.70 cmH2O with So2. Maximal expiratory flow at 50% of control TLC increased significantly (P less than 0.05) from 3.22 to 0.25 l/s (mean +/- SE) to 5.84 +/- 0.69 l/s with Sair and to 5.50 +/- 0.68 l/s with So2. With Sair, no significant increase in Qs/Qt from control was observed. With So2, mean Qs/Qt increased significantly (P less than 0.05) from 0 to 2.2 +/- 0.9% of the cardiac output. It is therefore unlikely that the development of atelectasis, as indicated by an increase in Qs/Qt, accounts for the increase in Pst (L) with Sair and So2. Current evidence suggests that either change in alveolar surface compliance or distortion of the lung or both are responsible for the increased recoil pressure but that neither mechanism alone appears to explain it totally.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Altered Respiratory Physiology in Obesity
Parameswaran, K., Todd, D. C., & Soth, M. (2006) · Canadian Respiratory Journal · doi:10.1155/2006/834786 · Cited by 527
Rothen, H. U., Sporre, B., Engberg, G., Wegenius, G., Hogman, M., & Hedenstierna, G. (1995) · Anesthesiology · doi:10.1097/00000542-199504000-00004 · Cited by 363
Airway clearance techniques in neuromuscular disorders: A state of the art review
Chatwin, M., Toussaint, M., Gonçalves, M. R., Sheers, N., Mellies, U., Gonzales-Bermejo, J., Sancho, J., Fauroux, B., Andersen, T., Hov, B., et al. (2018) · Respiratory Medicine · doi:10.1016/j.rmed.2018.01.012 · Cited by 325
Physiologic Basis for Improved Pulmonary Function after Lung Volume Reduction
Fessler, H. E., Scharf, S. M., Ingenito, E. P., McKenna, R. J., & Sharafkhaneh, A. (2008) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200708-117et · Cited by 84
“Similar findings have been described in normal subjects subjected to chest strapping (26).”
Metadata
- Authors
- Klineberg, P. L., Rehder, K., & Hyatt, R. E.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1981-07-01
- Volume
- 51
- Issue
- 1
- Pages
- 26-32
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2147315112
- Cited by
- 46
- References
- 0
- FWCI
- 1.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pulmonary mechanics and gas exchange in seated normal men with chest restriction. https://app.cochat.ai/papers/10.1152/jappl.1981.51.1.26
- The paper
- Klineberg, P. L., Rehder, K., & Hyatt, R. E. (1981). Pulmonary mechanics and gas exchange in seated normal men with chest restriction. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1981.51.1.26
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.