Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 363

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Influence of Gas Composition on Recurrence of Atelectasis after a Reexpansion Maneuver during General Anesthesia

Open access
Rothen, Hans Ulrich, Sporre, Bengt, Engberg, Greta, Wegenius, Goran, Hogman, Marieann, Hedenstierna, Goran · 1995 · Anesthesiology

Abstract

Background: Atelectasis, an important cause of impaired gas exchange during general anesthesia, may be eliminated by a vital capacity maneuver. However, it is not clear whether such a maneuver will have a sustained effect. The aim of this study was to determine the impact of gas composition on reappearance of atelectasis and impairment of gas exchange after a vital capacity maneuver. Methods: A consecutive sample of 12 adults with healthy lungs who were scheduled for elective surgery were studied. Thirty minutes after induction of anesthesia with fentanyl and propofol, the lungs were hyperinflated manually up to an airway pressure of 40 cmH2O. FIO2 was either kept at 0.4 (group 1, n = 6) or changed to 1.0 (group 2, n = 6) during the recruitment maneuver. Atelectasis was assessed by computed tomography. The amount of dense areas was measured at end-expiration in a transverse plane at the base of the lungs. The ventilation-perfusion distributions (VA/Q) were estimated with the multiple inert gas elimination technique. The static compliance of the total respiratory system (Crs) was measured with the flow interruption technique. Results: In group 1 (FIO2 = 0.4), the recruitment maneuver virtually eliminated atelectasis for at least 40 min, reduced shunt (VA/Q < 0.005), and increased at the same time the relative perfusion to poorly ventilated lung units (0.005 < VA/Q < 0.1; mean values are given). The arterial oxygen tension (PaO2) increased from 137 mmHg (18.3 kPa) to 163 mmHg (21.7 kPa; before and 40 min after recruitment, respectively; P = 0.028). In contrast to these findings, atelectasis recurred within 5 min after recruitment in group 2 (FIO2 = 1.0). Comparing the values before and 40 min after recruitment, all parameters of VA/Q were unchanged. In both groups, Crs increased from 57.1/55.0 ml.cmH2O-1 (group 1/group 2) before to 70.1/67.4 ml.cmH2O-1 after the recruitment maneuver. Crs showed a slow decrease thereafter (40 min after recruitment: 61.4/60.0 ml.cmH2O-1), with no difference between the two groups. Conclusions: The composition of inspiratory gas plays an important role in the recurrence of collapse of previously reexpanded atelectatic lung tissue during general anesthesia in patients with healthy lungs. The reason for the instability of these lung units remains to be established. The change in the amount of atelectasis and shunt appears to be independent of the change in the compliance of the respiratory system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-199504000-00004

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 363

Metadata

Authors
Rothen, H. U., Sporre, B., Engberg, G., Wegenius, G., Hogman, M., & Hedenstierna, G.
Venue
Anesthesiology
Published
1995-04-01
Volume
82
Issue
4
Pages
832-842.
ISSN
0003-3022 (ISSN-L)
OpenAlex
W1975734424
Cited by
363
References
15
FWCI
10.98
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Influence of Gas Composition on Recurrence of Atelectasis after a Reexpansion Maneuver during General Anesthesia. https://app.cochat.ai/papers/10.1097/00000542-199504000-00004
The paper
Rothen, H. U., Sporre, B., Engberg, G., Wegenius, G., Hogman, M., & Hedenstierna, G. (1995). Influence of Gas Composition on Recurrence of Atelectasis after a Reexpansion Maneuver during General Anesthesia. Anesthesiology. https://doi.org/10.1097/00000542-199504000-00004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.