"Anaerobic threshold": problems of determination and validation

Yeh, M. P., Gardner, R. M., Adams, T. D., Yanowitz, F. G., Crapo, R. O.·1983·Journal of Applied Physiology

Abstract

Despite the popularity of the concept of “anaerobic threshold” (AT), the noninvasive detection criteria remain subjective, and invasive validations of AT have been based on lactate data of arterial, mixed venous, venous, and capillary blood samples without any concern for the possible lactate differences from these sources. Eight normal subjects underwent two exercise tests on a bicycle ergometer. The protocol consisted of 3 min of rest, 3 min of 0 work load, and a 20 W/min ramp (1 W/3 s) until exhaustion. Simultaneous arterial and venous blood samples were drawn during the second test. Noninvasive gas response data were measured using a computerized breath-by-breath stress test system. Threshold phenomenon of the lactate accumulation was not found. The arterial lactate levels increased continuously after the start of the exercise ramp. The rise in venous lactate lagged behind the rise of the arterial lactate by about 1.5 min, and therefore venous lactate was not considered suitable for AT detection. Four independent exercise physiologists determined AT from the gas response data. The reviewer variability (avg range 16%) of AT for a given subject was representative of AT values reported for untrained and trained individuals (40-70% maximum O2 consumption). We concluded that 1) AT is not detectable using invasive methods (arterial and venous lactates); and 2) the noninvasive gas response determination has such a large range of reviewer variability that it is unsuitable for clinical use.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1983.55.4.1178

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 283

Metadata

Authors
Yeh, M. P., Gardner, R. M., Adams, T. D., Yanowitz, F. G., & Crapo, R. O.
Venue
Journal of Applied Physiology
Published
1983-10-01
Volume
55
Issue
4
Pages
1178-1186
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2188116472
Cited by
283
References
0
FWCI
14.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: "Anaerobic threshold": problems of determination and validation. https://app.cochat.ai/papers/10.1152/jappl.1983.55.4.1178
The paper
Yeh, M. P., Gardner, R. M., Adams, T. D., Yanowitz, F. G., & Crapo, R. O. (1983). "Anaerobic threshold": problems of determination and validation. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1983.55.4.1178

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.