"Anaerobic threshold": problems of determination and validation
The DOI matches its Crossref record.
Abstract
Despite the popularity of the concept of “anaerobic threshold” (AT), the noninvasive detection criteria remain subjective, and invasive validations of AT have been based on lactate data of arterial, mixed venous, venous, and capillary blood samples without any concern for the possible lactate differences from these sources. Eight normal subjects underwent two exercise tests on a bicycle ergometer. The protocol consisted of 3 min of rest, 3 min of 0 work load, and a 20 W/min ramp (1 W/3 s) until exhaustion. Simultaneous arterial and venous blood samples were drawn during the second test. Noninvasive gas response data were measured using a computerized breath-by-breath stress test system. Threshold phenomenon of the lactate accumulation was not found. The arterial lactate levels increased continuously after the start of the exercise ramp. The rise in venous lactate lagged behind the rise of the arterial lactate by about 1.5 min, and therefore venous lactate was not considered suitable for AT detection. Four independent exercise physiologists determined AT from the gas response data. The reviewer variability (avg range 16%) of AT for a given subject was representative of AT values reported for untrained and trained individuals (40-70% maximum O2 consumption). We concluded that 1) AT is not detectable using invasive methods (arterial and venous lactates); and 2) the noninvasive gas response determination has such a large range of reviewer variability that it is unsuitable for clinical use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ATS/ACCP statement on cardiopulmonary exercise testing
(2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.167.2.211 · Cited by 3,026
ATS/ACCP statement on cardiopulmonary exercise testing
Ross, R. M. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.167.10.950 · Cited by 2,073
Lactate Threshold Concepts: How Valid are They?
Faude, O., Kindermann, W., & Meyer, T. (2009) · Sports Medicine · doi:10.2165/00007256-200939060-00003 · Cited by 882
Di Salvo, T. G., Mathier, M., Semigran, M. J., & Dec, G. W. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)00511-n · Cited by 685
Circadian Rhythms in Sports Performance—an Update
Drust, B., Waterhouse, J., Atkinson, G., Edwards, B., & Reilly, T. (2005) · Chronobiology International · doi:10.1081/cbi-200041039 · Cited by 636
Cardiopulmonary exercise testing and its application
Albouaini, K., Egred, M., Alahmar, A., & Wright, D. J. (2007) · Postgraduate Medical Journal · doi:10.1136/hrt.2007.121558 · Cited by 582
Comparison of the ramp versus standard exercise protocols
Myers, J., Buchanan, N., Walsh, D., Kraemer, M., McAuley, P., Hamilton-Wessler, M., & Froelicher, V. F. (1991) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(10)80144-5 · Cited by 536
Binder, R. K., Wonisch, M., Corra, U., Cohen-Solal, A., Vanhees, L., Saner, H., & Schmid, J.-P. (2008) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1097/hjr.0b013e328304fed4 · Cited by 487
Baba, R., Nagashima, M., Goto, M., Nagano, Y., Yokota, M., Tauchi, N., & Nishibata, K. (1996) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00412-3 · Cited by 479
Anaerobic Threshold: The Concept and Methods of Measurement
Svedahl, K., & MacIntosh, B. R. (2003) · Canadian Journal of Applied Physiology · doi:10.1139/h03-023 · Cited by 472
Svensson, M., & Drust, B. (2005) · Journal of Sports Sciences · doi:10.1080/02640410400021294 · Cited by 464
Improved detection of lactate threshold during exercise using a log-log transformation
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1985) · Journal of Applied Physiology · doi:10.1152/jappl.1985.59.6.1936 · Cited by 457
Lactate metabolism: historical context, prior misinterpretations, and current understanding
Ferguson, B. S., Rogatzki, M. J., Goodwin, M. L., Kane, D. A., Rightmire, Z., & Gladden, L. B. (2018) · European Journal of Applied Physiology · doi:10.1007/s00421-017-3795-6 · Cited by 441
Mezzani, A., Agostoni, P., Cohen-Solal, A., Corrà, U., Jegier, A., Kouidi, E., Mazic, S., Meurin, P., Piepoli, M., Simon, A., et al. (2009) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1097/hjr.0b013e32832914c8 · Cited by 402
Olsen, S. L., Gilbert, E. M., Renlund, D. G., Taylor, D. O., Yanowitz, F. D., & Bristow, M. R. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00012-s · Cited by 373
Self-citationMethods of Prescribing Relative Exercise Intensity: Physiological and Practical Considerations
Mann, T., Lamberts, R. P., & Lambert, M. I. (2013) · Sports Medicine · doi:10.1007/s40279-013-0045-x · Cited by 333
“This may be partly attributed to differences in protocol and study design, including, in some cases, the reliability with which investigators are able to identify threshold measurements by visual inspection [118, 119].”
BackgroundHollenberg, M., & Tager, I. B. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00691-4 · Cited by 304
Methods to Determine Aerobic Endurance
Bosquet, L., L??ger, L., & Legros, P. (2002) · Sports Medicine · doi:10.2165/00007256-200232110-00002 · Cited by 279
Blood Lactate: Implications for Training and Sports Performance
Jacobs, I. (1986) · Sports Medicine · doi:10.2165/00007256-198603010-00003 · Cited by 278
Response of ventilatory and lactate thresholds to continuous and interval training
Poole, D. C., & Gaesser, G. A. (1985) · Journal of Applied Physiology · doi:10.1152/jappl.1985.58.4.1115 · Cited by 223
Myers, J., & Ashley, E. (1997) · Chest · doi:10.1378/chest.111.3.787 · Cited by 200
Hopker, J. G., Jobson, S. A., & Pandit, J. J. (2011) · Anaesthesia · doi:10.1111/j.1365-2044.2010.06604.x · Cited by 175
Matura, S., Fleckenstein, J., Deichmann, R., Engeroff, T., Füzéki, E., Hattingen, E., Hellweg, R., Lienerth, B., Pilatus, U., Schwarz, S., et al. (2017) · Translational Psychiatry · doi:10.1038/tp.2017.135 · Cited by 97
Cortisol and testosterone dynamics following exhaustive endurance exercise
Anderson, T., Lane, A. R., & Hackney, A. C. (2016) · European Journal of Applied Physiology · doi:10.1007/s00421-016-3406-y · Cited by 91
Reliability of assessments of ventilatory thresholds
Prud'Homme, D., Bouchard, C., Leblance, C., Landry, F., Lortie, G., & Boulay, M. R. (1984) · Journal of Sports Sciences · doi:10.1080/02640418408729692 · Cited by 49
Kim, K. J., Rivas, E., Prejean, B., Frisco, D., Young, M., & Downs, M. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.782167 · Cited by 17
“Examining the ventilatory profile during incremental exercise to a maximum effort has been used to assess aerobic fitness and monitor and prescribe exercise training in athletes and clinical populations with decades of controversy (Yeh et al., 1983; Poole et al., 2021).”
BackgroundMethod
Metadata
- Authors
- Yeh, M. P., Gardner, R. M., Adams, T. D., Yanowitz, F. G., & Crapo, R. O.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1983-10-01
- Volume
- 55
- Issue
- 4
- Pages
- 1178-1186
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2188116472
- Cited by
- 283
- References
- 0
- FWCI
- 14.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.