Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 260

The DOI matches its Crossref record.

Laser-Doppler measurement of skin blood flow: comparison with plethysmography

Johnson, J. M., Taylor, W. F., Shepherd, A. P., Park, M. K.·1984·Journal of Applied Physiology

Abstract

We compared laser-Doppler velocimetry with plethysmographically determined changes in skin blood flow (SkBF) in five studies on four men. Increments in SkBF were induced by raising whole-body skin temperature to 39 degrees C for 50–70 min. We found laser-Doppler blood flow (LDF) to correlate well with total forearm blood flow (FBF) within each study (r = 0.94–0.98), but the relationship varied among studies. Thus the slopes for the LDF vs. FBF relationship varied from 40 to 122 mV X ml-1 X 100 ml X min. The value for LDF at zero FBF, extrapolated from the regression relationships, ranged from 246 to 599 mV above the value for LDF set with the probe on a stationary object. The value for LDF when blood flow to the arm was mechanically occluded ranged from 110 to 230 mV. In a second series, we measured the LDF values from six sites on forearms of each of four normothermic men. There was marked regional variation, with 1.8- to 5.7-fold ranges in LDF within a given subject. Values for LDF during occlusion of the forearm were more consistent within and between subjects. Thus LDF appears to provide a good indicator of the response pattern of SkBF from the region of illuminated skin. However, variability in the relationship to total SkBF (probably arising from variation in the number of perfused capillaries in the small volume of tissue) and uncertainties in the value of LDF at zero SkBF make quantitative use difficult.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1984.56.3.798

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 260

Metadata

Authors
Johnson, J. M., Taylor, W. F., Shepherd, A. P., & Park, M. K.
Venue
Journal of Applied Physiology
Published
1984-03-01
Volume
56
Issue
3
Pages
798-803
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W1932619001
Cited by
260
References
0
FWCI
5.06
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Laser-Doppler measurement of skin blood flow: comparison with plethysmography. https://app.cochat.ai/papers/10.1152/jappl.1984.56.3.798
The paper
Johnson, J. M., Taylor, W. F., Shepherd, A. P., & Park, M. K. (1984). Laser-Doppler measurement of skin blood flow: comparison with plethysmography. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1984.56.3.798

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.