Laser-Doppler measurement of skin blood flow: comparison with plethysmography
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
We compared laser-Doppler velocimetry with plethysmographically determined changes in skin blood flow (SkBF) in five studies on four men. Increments in SkBF were induced by raising whole-body skin temperature to 39 degrees C for 50–70 min. We found laser-Doppler blood flow (LDF) to correlate well with total forearm blood flow (FBF) within each study (r = 0.94–0.98), but the relationship varied among studies. Thus the slopes for the LDF vs. FBF relationship varied from 40 to 122 mV X ml-1 X 100 ml X min. The value for LDF at zero FBF, extrapolated from the regression relationships, ranged from 246 to 599 mV above the value for LDF set with the probe on a stationary object. The value for LDF when blood flow to the arm was mechanically occluded ranged from 110 to 230 mV. In a second series, we measured the LDF values from six sites on forearms of each of four normothermic men. There was marked regional variation, with 1.8- to 5.7-fold ranges in LDF within a given subject. Values for LDF during occlusion of the forearm were more consistent within and between subjects. Thus LDF appears to provide a good indicator of the response pattern of SkBF from the region of illuminated skin. However, variability in the relationship to total SkBF (probably arising from variation in the number of perfused capillaries in the small volume of tissue) and uncertainties in the value of LDF at zero SkBF make quantitative use difficult.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The measurement of volume changes in human limbs
Whitney, R. J. (1953) · The Journal of Physiology · doi:10.1113/jphysiol.1953.sp004926 · Cited by 1,489
Evaluation of a Laser Doppler Flowmeter for Measurement of Tissue Blood Flow
Nilsson, G. E., Tenland, T., & Oberg, P. A. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326582 · Cited by 1,095
In vivo evaluation of microcirculation by coherent light scattering
STERN, M. D. (1975) · Nature · doi:10.1038/254056a0 · Cited by 857
Model for laser Doppler measurements of blood flow in tissue
Bonner, R., & Nossal, R. (1981) · Applied Optics · doi:10.1364/ao.20.002097 · Cited by 836
A New Instrument for Continuous Measurement of Tissue Blood Flow by Light Beating Spectroscopy
Nilsson, G. E., Tenland, T., & Oberg, P. A. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326686 · Cited by 591
Continuous measurement of tissue blood flow by laser-Doppler spectroscopy
Stern, M. D., Lappe, D. L., Bowen, P. D., Chimosky, J. E., Holloway, G. A., Keiser, H. R., & Bowman, R. L. (1977) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1977.232.4.h441 · Cited by 445
Cardiovascular responses to sustained high skin temperature in resting man.
Rowell, L. B., Brengelmann, G. L., & Murray, J. A. (1969) · Journal of Applied Physiology · doi:10.1152/jappl.1969.27.5.673 · Cited by 272
Skin and muscle components of forearm blood flow in directly heated resting man.
Detry, J. M., Brengelmann, G. L., Rowell, L. B., & Wyss, C. (1972) · Journal of Applied Physiology · doi:10.1152/jappl.1972.32.4.506 · Cited by 209
Forearm skin and muscle vascular responses to prolonged leg exercise in man
Johnson, J. M., & Rowell, L. B. (1975) · Journal of Applied Physiology · doi:10.1152/jappl.1975.39.6.920 · Cited by 205
Self-citationAn Instrument to Measure Cutaneous Blood Flow Using the Doppler Shift of Laser Light
Watkins, D., & Holloway, G. A. (1978) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1978.326374 · Cited by 201
Cited by
Skin blood flow in adult human thermoregulation: How it works, when it does not, and why
Charkoudian, N. (2003) · Mayo Clinic Proceedings · doi:10.4065/78.5.603 · Cited by 1,041
“Measurement of skin blood flow is usually accomplished by laser Doppler flowmetry or venous occlusion plethysmography.[1,23,24] Laser Doppler measurement of skin”
BackgroundInvestigation of Chronic Venous Insufficiency: A Consensus Statement
Nicolaides, A. N. (2000) · Circulation · doi:10.1161/01.cir.102.20.e126 · Cited by 945
Dirnagl, U., Kaplan, B., Jacewicz, M., & Pulsinelli, W. (1989) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1989.84 · Cited by 475
Cutaneous Vasodilator and Vasoconstrictor Mechanisms in Temperature Regulation
Johnson, J. M., Minson, C. T., & Kellogg, D. L. (2014) · Comprehensive Physiology · doi:10.1002/cphy.c130015 · Cited by 414
Self-citationLocal thermal control of the human cutaneous circulation
Johnson, J. M., & Kellogg, D. L. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00407.2010 · Cited by 324
Self-citationFinger cold-induced vasodilation: a review
Daanen, H. A. M. (2003) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0818-2 · Cited by 289
Sato, K., Ogoh, S., Hirasawa, A., Oue, A., & Sadamoto, T. (2011) · The Journal of Physiology · doi:10.1113/jphysiol.2010.204461 · Cited by 276
Laser Speckle Contrast Imaging: Theory, Instrumentation and Applications
Senarathna, J., Rege, A., Li, N., & Thakor, N. V. (2013) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2013.2243140 · Cited by 269
Fingertip temperature as an indicator for sympathetic responses
Kistler, A., Mariauzouls, C., & von Berlepsch, K. (1998) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(97)00087-1 · Cited by 207
Statins enhance postischemic hyperemia in the skin circulation of hypercholesterolemic patients
Binggeli, C., Spieker, L. E., Corti, R., Sudano, I., Stojanovic, V., Hayoz, D., Lüscher, T. F., & Noll, G. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00505-9 · Cited by 175
Sex differences in control of cutaneous blood flow.
Cooke, J. P., Creager, M. A., Osmundson, P. J., & Shepherd, J. T. (1990) · Circulation · doi:10.1161/01.cir.82.5.1607 · Cited by 165
Effects of climatic temperature stress on cardiovascular diseases
Cheng, X., & Su, H. (2010) · European Journal of Internal Medicine · doi:10.1016/j.ejim.2010.03.001 · Cited by 163
“plethysmography [65] andfinger skin temperature [66].”
Inoue, Y., Tanaka, Y., Omori, K., Kuwahara, T., Ogura, Y., & Ueda, H. (2005) · European Journal of Applied Physiology · doi:10.1007/s00421-004-1303-2 · Cited by 158
“The LDF values were converted to a percentage of the baseline LDF value (%LDF) in line with the opinion of Johnson et al. (1984) that in usage of laser Doppler flowmetry, regionto-region or study-to-study comparison must be made with caution.”
MethodThermoregulatory and thermal control in the human cutaneous circulation
Kellogg, D. L. (2010) · Frontiers in Bioscience · doi:10.2741/s105 · Cited by 137
“Fortunately, despite differences in the absolute levels of blood flow among different sites, the pattern of the response to given local or reflex perturbations is quite similar among sites (10, 11).”
BackgroundCircadian variation in peripheral blood flow in relation to core temperature at rest
Smolander, J., H�rm�, M., Lindgvist, A., Kolari, P., & Laitinen, L. A. (1993) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00376666 · Cited by 87
“Skin blood flow was measured for l-rain periods from the forehead, forearm, and the palmar side of the middle phalanx of the left middle finger by laserDoppler flowmetry (Nilsson et al. 1980; Johnson et al. 1984; Smolander and Kolari 1985).”
MethodDecreased Microvascular Nitric Oxide–Dependent Vasodilation in Postural Tachycardia Syndrome
Medow, M. S., Minson, C. T., & Stewart, J. M. (2005) · Circulation · doi:10.1161/circulationaha.104.526764 · Cited by 74
Cutaneous neuronal nitric oxide is specifically decreased in postural tachycardia syndrome
Stewart, J. M., Medow, M. S., Minson, C. T., & Taneja, I. (2007) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00600.2007 · Cited by 68
Functional gastrointestinal disease and the autonomic nervous system: a way ahead?
Camilleri, M., & Ford, M. J. (1994) · Gastroenterology · doi:10.1016/0016-5085(94)90775-7 · Cited by 64
Shibahara, N., Matsuda, H., Umeno, K., Shimada, Y., Itoh, T., & Terasawa, K. (1996) · Journal of the Autonomic Nervous System · doi:10.1016/s0165-1838(96)00065-3 · Cited by 28
Metadata
- Authors
- Johnson, J. M., Taylor, W. F., Shepherd, A. P., & Park, M. K.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1984-03-01
- Volume
- 56
- Issue
- 3
- Pages
- 798-803
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1932619001
- Cited by
- 260
- References
- 24
- FWCI
- 5.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.