CoChat

Respiratory muscle oxygen consumption estimated by the diaphragm pressure-time index

Field, S., Sanci, S., Grassino, A. · 1984 · Journal of Applied Physiology
Cited by 170

The DOI matches its Crossref record.

Abstract

The O2 consumption of the respiratory muscles (VO2resp), work of breathing, and the time integral of the transdiaphragmatic pressure (TTdi) were measured in four normal subjects breathing against inspiratory resistance. A total of 39 runs were performed at mean tidal transdiaphragmatic pressures (Pdi) ranging from 15 to 53 cmH2O, respiratory frequencies from 3.5 to 22 breaths/min, and inspiratory time durations (TI) from 32 to 76% of the total breath duration. Each run was maintained from 8 to 17 min and the above parameters were kept constant by the subject via visual feedback of Pdi and TI with an oscilloscope. Most of the runs (36 of 39) were performed at TTdi values below those known to produce respiratory muscle fatigue. We found a strong linear correlation between the VO2resp and the TTdi (r = 0.74, P less than 0.001) and a weaker correlation between VO2resp and W (r = 0.31, P less than 0.05). These data suggest that TTdi is a good estimator of VO2resp over a wide range of respiratory patterns during inspiratory resistance breathing. The high variability seen in respiratory muscle efficiency during resistive breathing may be due to W not being a good indicator of the energy consumed by the respiratory muscles.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1984.57.1.44

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Field, S., Sanci, S., & Grassino, A.
Venue
Journal of Applied Physiology
Published
1984-07-01
Volume
57
Issue
1
Pages
44-51
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W1830229022
Cited by
170
References
0
FWCI
2.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.