Mechanical impedance as determinant of inspiratory neural drive during exercise in humans
The DOI matches its Crossref record.
Abstract
Five healthy males exercised progressively with small 2-min increments in work load. We measured inspiratory drive (occlusion pressure, P0.1), pulmonary resistance (RL), dynamic pulmonary compliance (Cdyn), transdiaphragmatic pressure (Pdi), and diaphragmatic electromyogram (EMGdi). Minute ventilation (VE), mean inspiratory flow rate (VT/TI), and P0.1 all increased exponentially with increased work load, but P0.1 increased at a faster rate than did VT/TI or VE. Thus effective impedance (P0.1/VT/TI) rose throughout exercise. The increasing P0.1 was mostly due to augmented Pdi and coincided with increased EMGdi during this initial portion of inspiration. We found no consistent change in RL or Cdyn throughout exercise. With He breathing (80% He-20% O2), RL was reduced at all work loads; P0.1 fell in comparison with air-breathing values and VE, VT, and VT/TI rose in moderate and heavy work; and P0.1/VT/TI was unchanged with increasing exercise loads. Step reductions in gas density at a constant work load of any intensity showed an immediate reduction in the rate of rise of EMGdi and Pdi followed by increased VT/TI, breathing frequency, and hypocapnia. These changes were maintained during prolonged periods of unloading and were immediately reversible on return to air breathing. These data are consistent with the existence of a reflex effect on the magnitude of inspiratory neural drive during exercise that is sensitive to the load presented by the normal mechanical time constant of the respiratory system. This “load” is a significant determinant of the hyperpneic response and thus of the maintenance of normocapnia during exercise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Reflexes Controlling Circulatory, Ventilatory and Airway Responses to Exercise
Kaufman, M. P., & Forster, H. V. (1996) · Comprehensive Physiology · doi:10.1002/cphy.cp120110 · Cited by 315
Smaller lungs in women affect exercise hyperpnea
McClaran, S. R., Harms, C. A., Pegelow, D. F., & Dempsey, J. A. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.84.6.1872 · Cited by 238
“(18) observed an increased ventilatory response with HeO2 breathing even during moderate exercise when flow limitation was highly unlikely.”
BackgroundSelf-citationEffects of obesity on breathing pattern, ventilatory neural drive and mechanics
Chlif, M., Keochkerian, D., Choquet, D., Vaidie, A., & Ahmaidi, S. (2009) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2009.06.012 · Cited by 173
Fat Distribution and End-Expiratory Lung Volume in Lean and Obese Men and Women
Babb, T. G., Wyrick, B. L., DeLorey, D. S., Chase, P. J., & Feng, M. Y. (2008) · Chest · doi:10.1378/chest.07-1728 · Cited by 136
Metadata
- Authors
- Hussain, S. N., Pardy, R. L., & Dempsey, J. A.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1985-08-01
- Volume
- 59
- Issue
- 2
- Pages
- 365-375
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1962545631
- Cited by
- 73
- References
- 0
- FWCI
- 4.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanical impedance as determinant of inspiratory neural drive during exercise in humans. https://app.cochat.ai/papers/10.1152/jappl.1985.59.2.365
- The paper
- Hussain, S. N., Pardy, R. L., & Dempsey, J. A. (1985). Mechanical impedance as determinant of inspiratory neural drive during exercise in humans. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1985.59.2.365
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.