CoChat

Breathlessness during exercise with and without resistive loading

el-Manshawi, A., Killian, K. J., Summers, E., Jones, N. L. · 1986 · Journal of Applied Physiology
Cited by 233

The DOI matches its Crossref record.

Abstract

The purpose of this study was to quantify the intensity of breathlessness associated with exercise and respiratory resistive loading, with the specific purpose of isolating the quantitative contributions of inspiratory pressure, length, velocity, and frequency of inspiratory muscle shortening and duty cycle to breathlessness. The intensity of inspiratory pressure was quantified by measurement of estimated esophageal pressure (Pes = pressure at the mouth plus lung pressure), the extent of shortening by tidal volume (VT), and the velocity of shortening by inspiratory flow rate (VI). Six normal subjects underwent five incremental (100 kpm X min-1 X min-1) exercise tests on a cycle ergometer to maximum capacity. The first and last test were unloaded and the intervening tests were performed with external added resistances of 33, 57, and 73 cm H2O X l-1 X s in random order. The resistances were selected to provide a range of pressures, tidal volumes, flow rates, and patterns of breathing. At rest and at the end of each minute during exercise the subjects estimated the intensity of breathlessness (psi) by selecting a number ranging from 0 to 10 (Borg rating scale, 0 indicating no appreciable breathlessness and 10 the maximum tolerable sensation). Breathlessness was significantly and independently related to Pes (P less than 0.0001), VI (P less than 0.0001), frequency of breathing (fb) (P less than 0.01), and duty cycle [ratio of inspiratory duration to total breath duration (TI/TT)] (P less than 0.01): psi = 0.11 Pes + 0.61 VI + 1.99 TI/TT + 0.04 fb - 2.60 (r = 0.83). The results suggest that peak pressure (tension), VI (velocity of inspiratory muscle shortening), TI/TT, and fb contribute independently and collectively to breathlessness. The perception of respiratory muscle effort is ideally suited to subserve this sensation. The neurophysiological mechanism purported is a conscious awareness of the intensity of the outgoing motor command by means of corollary discharge within the central nervous system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1986.61.3.896

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Still being checked.

Cited by

See all 233

Metadata

Authors
el-Manshawi, A., Killian, K. J., Summers, E., & Jones, N. L.
Venue
Journal of Applied Physiology
Published
1986-09-01
Volume
61
Issue
3
Pages
896-905
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W1912369005
Cited by
211
References
0
FWCI
10.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.