Effects of electrode location on myoelectric conduction velocity and median frequency estimates
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
The effect of surface electrode location on the estimates of the median frequency and conduction velocity of the myoelectric signal was investigated. The locations were identified with respect to the innervation zone and the tendonous portion of the tibialis anterior muscle. Considerable modifications in the median frequency and conduction velocity parameters were noted. The highest values of the median frequency occurred at the region of the innervation zone and tendonous insertion of the muscle, and decreased proportionally with distance from these areas. The rate of change of median frequency was not effected by electrode location. Estimates of conduction velocity were most stable in a region between the distal tendon and the adjacent innervation zone. This region also provided the best linear fit when comparing conduction velocity to median frequency estimates. The implications for signal detection procedures are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Myoelectrical manifestations of localized muscular fatigue in humans.
Luca, C. J. D. (1984) · PubMed · Cited by 1,121
Muscle Architecture of the Human Lower Limb
Wickiewicz, T. L., Roy, R. R., Powell, P. L., & Edgerton, V. R. (1983) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198310000-00042 · Cited by 928
RELATIONS BETWEEN STRUCTURE AND FUNCTION IN THE DESIGN OF SKELETAL MUSCLES
Henneman, E., & Olson, C. B. (1965) · Journal of Neurophysiology · doi:10.1152/jn.1965.28.3.581 · Cited by 763
Frequency Parameters of the Myoelectric Signal as a Measure of Muscle Conduction Velocity
Stulen, F. B., & De Luca, C. J. (1981) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1981.324738 · Cited by 576
Self-citationConduction velocity and EMG power spectrum changes in fatigue of sustained maximal efforts
Bigland-Ritchie, B., Donovan, E. F., & Roussos, C. S. (1981) · Journal of Applied Physiology · doi:10.1152/jappl.1981.51.5.1300 · Cited by 447
Myoelectric signal conduction velocity and spectral parameters: influence of force and time
Broman, H., Bilotto, G., & De Luca, C. J. (1985) · Journal of Applied Physiology · doi:10.1152/jappl.1985.58.5.1428 · Cited by 260
Self-citationMedian frequency of the myoelectric signal: Effects of muscle ischemia and cooling
Merletti, R., Sabbahi, M. A., & Luca, C. J. D. (1984) · European Journal of Applied Physiology · doi:10.1007/bf01015206 · Cited by 149
A Note on the Noninvasive Estimation of Muscle Fiber Conduction Velocity
Broman, H., Bilotto, G., & De Luca, C. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325550 · Cited by 134
Self-citationNaeije, M., & Zorn, H. (1982) · European Journal of Applied Physiology · doi:10.1007/bf00952241 · Cited by 131
HUDDART, H. (1975) · Elsevier eBooks · doi:10.1016/b978-0-08-017845-5.50007-x · Cited by 74
Cited by
ATS/ERS Statement on Respiratory Muscle Testing
(2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.166.4.518 · Cited by 2,841
The extraction of neural strategies from the surface EMG
Farina, D., Merletti, R., & Enoka, R. M. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01070.2003 · Cited by 1,573
“Because different electrode locations over the same muscle can provide signals with significantly different features, some locations are preferred over others (41, 71).”
Myoelectric manifestations of fatigue in voluntary and electrically elicited contractions
Merletti, R., Knaflitz, M., & De Luca, C. J. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.69.5.1810 · Cited by 610
Self-citationA method for positioning electrodes during surface EMG recordings in lower limb muscles
Rainoldi, A., Melchiorri, G., & Caruso, I. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.014 · Cited by 610
The extraction of neural strategies from the surface EMG: an update
Farina, D., Merletti, R., & Enoka, R. M. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00162.2014 · Cited by 589
Effects of muscle fiber type and size on EMG median frequency and conduction velocity
Kupa, E. J., Roy, S. H., Kandarian, S. C., & De Luca, C. J. (1995) · Journal of Applied Physiology · doi:10.1152/jappl.1995.79.1.23 · Cited by 458
Self-citationInterpretation of EMG changes with fatigue: facts, pitfalls, and fallacies
Dimitrova, N. A., & Dimitrov, G. V. (2003) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(02)00083-4 · Cited by 458
Influence of anatomical, physical, and detection-system parameters on surface EMG
Farina, D., Cescon, C., & Merletti, R. (2002) · Biological Cybernetics · doi:10.1007/s00422-002-0309-2 · Cited by 373
A Review of Non-Invasive Techniques to Detect and Predict Localised Muscle Fatigue
Al-Mulla, M. R., Sepulveda, F., & Colley, M. (2011) · Sensors · doi:10.3390/s110403545 · Cited by 310
Tutorial. Surface EMG detection in space and time: Best practices
Merletti, R., & Muceli, S. (2019) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2019.102363 · Cited by 290
Young, A. J., Hargrove, L. J., & Kuiken, T. A. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2159216 · Cited by 287
The linear electrode array: a useful tool with many applications
Merletti, R., Farina, D., & Gazzoni, M. (2003) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(02)00082-2 · Cited by 285
“[12], who indicated the variability of fatigue indexes and surface EMG variable initial values with electrode position, depending on the muscle anatomy.”
BackgroundBonato, P., Roy, S. H., Knaflitz, M., & de Luca, C. J. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.930899 · Cited by 284
Self-citationFalla, D., Dall'Alba, P., Rainoldi, A., Merletti, R., & Jull, G. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(01)00708-8 · Cited by 277
Inference of motor unit recruitment order in voluntary and electrically elicited contractions
Knaflitz, M., Merletti, R., & De Luca, C. J. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.68.4.1657 · Cited by 251
Self-citationSurface EMG signal processing during isometric contractions
Merletti, R., & Lo Conte, L. R. (1997) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(97)00010-2 · Cited by 227
Fibre conduction velocity and fibre composition in human vastus lateralis
Sadoyama, T., Masuda, T., Miyata, H., & Katsuta, S. (1988) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf01076001 · Cited by 224
“Furthermore, the spectral parameters are dependent on the frequency characteristics of electrodes and amplifiers, and are affected by the position of the electrodes with respect to the innervation zones (Masuda et al. 1985; Roy et al. 1986).”
BackgroundModeling of surface myoelectric signals. I. Model implementation
Merletti, R., Lo Conte, L., Avignone, E., & Guglielminotti, P. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.771190 · Cited by 208
“The simulations of Fig. 3 show that conduction velocity is overestimated near the innervation and termination zones and explain the results obtained by Roy et al. [ 52 ].”
BackgroundResultInfluentialRainoldi, A., Galardi, G., Maderna, L., Comi, G., Lo Conte, L., & Merletti, R. (1999) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(98)00042-x · Cited by 203
“The high quality of estimate of EMG variables in biceps brachii is probably due to the long and parallel fibers of the muscle and to the availability of sufficient space to place the EMG electrodes between the motor points and the tendon endings [42].”
BackgroundFarina, D., Fattorini, L., Felici, F., & Filligoi, G. (2002) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00314.2002 · Cited by 203
Surface EMG: The issue of electrode location
Mesin, L., Merletti, R., & Rainoldi, A. (2009) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2008.07.006 · Cited by 200
“Multichannel montage (with N > 2) must be used in this region if muscle fiber CV is to be estimated and if limited sensitivities of amplitude and spectral estimates with respect to electrode displacement are desired (Farina et al., 2002a,b; Hogrel et al., 1998; Roy et al., 1986 ).”
BackgroundMethodDependence of the mean power frequency of the electromyogram on muscle force and fibre type
GERDLE, B., HENRIKSSON‐LARSÉN, K., LORENTZON, R., & WRETLING, M. ‐. (1991) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1991.tb09180.x · Cited by 199
Effect of joint angle on EMG variables in leg and thigh muscles
Farina, D., Merletti, R., Nazzaro, M., & Caruso, I. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.982277 · Cited by 197
Geometrical factors in surface EMG of the vastus medialis and lateralis muscles
Rainoldi, A., Nazzaro, M., Merletti, R., Farina, D., Caruso, I., & Gaudenti, S. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00024-9 · Cited by 192
Force and EMG power spectrum during eccentric and concentric actions
KOMI, P. V., LINNAMO, V., SILVENTOINEN, P., & SILLANP????, M. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200010000-00015 · Cited by 190
Farina, D., Muhammad, W., Fortunato, E., Meste, O., Merletti, R., & Rix, H. (2001) · Medical and Biological Engineering and Computing · doi:10.1007/bf02344807 · Cited by 181
Effect of age on muscle functions investigated with surface electromyography
Merletti, R., Farina, D., Gazzoni, M., & Schieroni, M. P. (2002) · Muscle & Nerve · doi:10.1002/mus.10014 · Cited by 179
Muscle Fatigue during Dynamic Contractions Assessed by New Spectral Indices
DIMITROV, G. V., ARABADZHIEV, T. I., MILEVA, K. N., BOWTELL, J. L., CRICHTON, N., & DIMITROVA, N. A. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000233794.31659.6d · Cited by 174
Farina, D., Madeleine, P., Graven-Nielsen, T., Merletti, R., & Arendt-Nielsen, L. (2002) · European Journal of Applied Physiology · doi:10.1007/s00421-001-0574-0 · Cited by 168
“1970), inter-electrode distance (IED) and detection spatial filter (Korosec 1999; Merletti and Roy 1996; Merletti et al. 1999b, c; Roy et al. 1986).”
Clinical applications of surface electromyography in neuromuscular disorders
Hogrel, J.-Y. (2005) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/j.neucli.2005.03.001 · Cited by 164
Patterns of leg muscle recruitment vary between novice and highly trained cyclists
Chapman, A. R., Vicenzino, B., Blanch, P., & Hodges, P. W. (2008) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2005.12.007 · Cited by 161
“, 1994) and artifact due to electrode movement relative to the muscle (Rainoldi et al., 2000; Roy et al., 1986).”
BackgroundPhysiology and Interpretation of the Electromyogram
Kamen, G., & Caldwell, G. E. (1996) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199609000-00002 · Cited by 160
Electromyography and the study of sports movements: A review
Clarys, J. P., & Cabri, J. (1993) · Journal of Sports Sciences · doi:10.1080/02640419308730010 · Cited by 158
Creatine supplementation can improve impact control in high-intensity interval training
da Silva Azevedo, A. P., Michelone Acquesta, F., Lancha Jr., A. H., Bertuzzi, R., Poortmans, J. R., Amadio, A. C., & Cerca Serrão, J. (2019) · Nutrition · doi:10.1016/j.nut.2018.09.020 · Cited by 14
Metadata
- Authors
- Roy, S. H., De Luca, C. J., & Schneider, J.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1986-10-01
- Volume
- 61
- Issue
- 4
- Pages
- 1510-1517
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2132481753
- Cited by
- 260
- References
- 13
- FWCI
- 3.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.