The Effects of Electrode Size and Orientation on the Sensitivity of Myoelectric Pattern Recognition Systems to Electrode Shift

Open access
Young, A. J., Hargrove, L. J., Kuiken, T. A.·2011·IEEE Transactions on Biomedical Engineering

Abstract

Myoelectric pattern recognition systems for prosthesis control are often studied in controlled laboratory settings, but obstacles remain to be addressed before they are clinically viable. One important obstacle is the difficulty of maintaining system usability with socket misalignment. Misalignment inevitably occurs during prosthesis donning and doffing, producing a shift in electrode contact locations. We investigated how the size of the electrode detection surface and the placement of electrode poles (electrode orientation) affected system robustness with electrode shift. Electrodes oriented parallel to muscle fibers outperformed electrodes oriented perpendicular to muscle fibers in both shift and no-shift conditions (p < 0.01). Another finding was the significant difference (p < 0.01) in performance for the direction of electrode shift. Shifts perpendicular to the muscle fibers reduced classification accuracy and real-time controllability much more than shifts parallel to the muscle fibers. Increasing the size of the electrode detection surface was found to help reduce classification accuracy sensitivity to electrode shifts in a direction perpendicular to the muscle fibers but did not improve the real-time controllability of the pattern recognition system. One clinically important result was that a combination of longitudinal and transverse electrodes yielded high controllability with and without electrode shift using only four physical electrode pole locations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2011.2159216

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 34 references

Cited by

See all 287

Metadata

Authors
Young, A. J., Hargrove, L. J., & Kuiken, T. A.
Venue
IEEE Transactions on Biomedical Engineering
Published
2011-09
Volume
58
Issue
9
Pages
2537-2544
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2138967075
Cited by
287
References
34
FWCI
7.11
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Effects of Electrode Size and Orientation on the Sensitivity of Myoelectric Pattern Recognition Systems to Electrode Shift. https://app.cochat.ai/papers/10.1109/tbme.2011.2159216
The paper
Young, A. J., Hargrove, L. J., & Kuiken, T. A. (2011). The Effects of Electrode Size and Orientation on the Sensitivity of Myoelectric Pattern Recognition Systems to Electrode Shift. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2011.2159216

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.