Measurement of O2 consumption, CO2 production, and water vapor production in a closed system
The DOI matches its Crossref record.
Abstract
Equations for the calculation of O2 consumption, CO2 production, and water vapor production in a constant-volume, closed-system respirometer are presented. Necessary measurements include only the initial temperature, pressure, and gas volume in the respirometer chamber, and the fractional concentration of O2 in gas samples taken at the beginning and end of the period of measurement. Potential errors resulting from changes in CO2 and water vapor concentrations are identified. Ignoring CO2 effects can produce up to a 6.4% error in estimates of O2 consumption, and errors due to water vapor effects can exceed 100%. Techniques are presented for minimizing potential errors and for measuring CO2 and water vapor concentrations with an O2 analyzer so that potential errors can be eliminated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lighton, J. R. B. (2008) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780195310610.001.0001 · Cited by 739
Adaptive Responses to Feeding in Burmese Pythons: Pay Before Pumping
Secor, S. M., & Diamond, J. (1995) · Journal of Experimental Biology · doi:10.1242/jeb.198.6.1313 · Cited by 306
Periodic Cooling of Bird Eggs Reduces Embryonic Growth Efficiency
Olson, C. R., Vleck, C. M., & Vleck, D. (2006) · Physiological and Biochemical Zoology · doi:10.1086/506003 · Cited by 223
Self-citationDeterminants of the Postfeeding Metabolic Response of Burmese Pythons, Python molurus
Secor, S. M., & Diamond, J. (1997) · Physiological Zoology · doi:10.1086/639578 · Cited by 176
Secor, S. M., & Faulkner, A. C. (2002) · Physiological and Biochemical Zoology · doi:10.1086/344493 · Cited by 101
“We measured o2 and rates of carbon dioxide productionV̇ ( co2) of toads using closed-system respirometry as describedV̇ by Vleck (1987) and Secor and Diamond (1997a).”
MethodFolguera, G., Bastías, D. A., Caers, J., Rojas, J. M., Piulachs, M.-D., Bellés, X., & Bozinovic, F. (2011) · Comparative Biochemistry and Physiology Part A: Molecular & Integrative Physiology · doi:10.1016/j.cbpa.2011.03.002 · Cited by 98
Metabolism and life-history correlates in a lowland and highland population of a terrestrial isopod
Lardies, M. A., Catalán, T. P., & Bozinovic, F. (2004) · Canadian Journal of Zoology · doi:10.1139/z04-033 · Cited by 57
The energetics of reproduction and parental care in the terrestrial isopod Porcellio laevis
Lardies, M. A., Cotoras, I. S., & Bozinovic, F. (2004) · Journal of Insect Physiology · doi:10.1016/j.jinsphys.2004.10.005 · Cited by 40
“VO2 was determined using a ‘‘closed system’’ of metabolic chambers (Vleck, 1987) consisting in disposable 10 cm hermetic syringes fitted with three-way valves (see also Chappell, 1983; Ashby, 1997; Nespolo et al.”
Method
Metadata
- Authors
- Vleck, D.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1987-05-01
- Volume
- 62
- Issue
- 5
- Pages
- 2103-2106
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1878560378
- Cited by
- 177
- References
- 0
- FWCI
- 6.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.