Neuromuscular and mechanical responses to inspiratory resistive loading during sleep
The DOI matches its Crossref record.
Abstract
The purposes of this study were 1) to characterize the immediate inspiratory muscle and ventilation responses to inspiratory resistive loading during sleep in humans and 2) to determine whether upper airway caliber was compromised in the presence of a resistive load. Ventilation variables, chest wall, and upper airway inspiratory muscle electromyograms (EMG), and upper airway resistance were measured for two breaths immediately preceding and immediately following six applications of an inspiratory resistive load of 15 cmH2O.l–1 X s during wakefulness and stage 2 sleep. During wakefulness, chest wall inspiratory peak EMG activity increased 40 +/- 15% (SE), and inspiratory time increased 20 +/- 5%. Therefore, the rate of rise of chest wall EMG increased 14 +/- 10.9% (NS). Upper airway inspiratory muscle activity changed in an inconsistent fashion with application of the load. Tidal volume decreased 16 +/- 6%, and upper airway resistance increased 141 +/- 23% above pre-load levels. During sleep, there was no significant chest wall or upper airway inspiratory muscle or timing responses to loading. Tidal volume decreased 40 +/- 7% and upper airway resistance increased 188 +/- 52%, changes greater than those observed during wakefulness. We conclude that 1) the immediate inspiratory muscle and timing responses observed during inspiratory resistive loading in wakefulness were absent during sleep, 2) there was inadequate activation of upper airway inspiratory muscle activity to compensate for the increased upper airway inspiratory subatmospheric pressure present during loading, and 3) the alteration in upper airway mechanics during resistive loading was greater during sleep than wakefulness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mezzanotte, W. S., Tangel, D. J., & White, D. P. (1992) · Journal of Clinical Investigation · doi:10.1172/jci115751 · Cited by 769
Chemical Control Stability in Patients with Obstructive Sleep Apnea
YOUNES, M., OSTROWSKI, M., THOMPSON, W., LESLIE, C., & SHEWCHUK, W. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.5.2007013 · Cited by 439
Endocrine Aspects of Obstructive Sleep Apnea
Attal, P., & Chanson, P. (2010) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2009-1912 · Cited by 256
Influence of Sleep on Genioglossus Muscle Activation by Negative Pressure in Normal Men
Wheatley, J. R., Mezzanotte, W. S., Tangel, D. J., & White, D. P. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/148.3.597 · Cited by 211
Airway Mechanics and Ventilation in Response to Resistive Loading during Sleep
PILLAR, G., MALHOTRA, A., FOGEL, R., BEAUREGARD, J., SCHNALL, R., & WHITE, D. P. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.5.2003131 · Cited by 188
Metadata
- Authors
- Hudgel, D. W., Mulholland, M., & Hendricks, C.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1987-08-01
- Volume
- 63
- Issue
- 2
- Pages
- 603-608
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2405204171
- Cited by
- 56
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Neuromuscular and mechanical responses to inspiratory resistive loading during sleep. https://app.cochat.ai/papers/10.1152/jappl.1987.63.2.603
- The paper
- Hudgel, D. W., Mulholland, M., & Hendricks, C. (1987). Neuromuscular and mechanical responses to inspiratory resistive loading during sleep. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1987.63.2.603
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.