Use of 13C-labeled glucose for estimating glucose oxidation: some design considerations
The DOI matches its Crossref record.
Abstract
Use of 13C-labeled glucose for estimating in vivo rates of glucose oxidation faces several difficulties, particularly the accurate determination of the output of 13C in expired air. In an investigation of wholebody glucose metabolism in healthy adult humans, using a continuous intravenous infusion of D-[U-13C]glucose, we found that a precise estimate of the rate of glucose oxidation was difficult to achieve when the study included infusions with unlabeled glucose. Problems arose 1) as a result of the slow rate at which the 13CO2 released by glucose oxidation reaches an equilibrium in expired air CO2 and 2) due to the contribution to 13CO2 output by the natural 13C in the unlabeled glucose that was infused. In a subsequent series of experiments in healthy young adults, we found that the entry of 13CO2 released by the tissues into the bicarbonate pool and into the expired air is relatively slow and a tracer infusion protocol of approximately 6 h is required for determination of glucose oxidation. This applies when metabolic states are changed acutely during the experiment or when unlabeled glucose is infused. However, for resting subjects in the basal postabsorptive state we confirmed that the time required to achieve a steady state in the 13C enrichment of expired air can be shortened significantly by the use of a NaH13CO3 priming dose, even when this dose varies from the ideal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Oxidation of combined ingestion of glucose and fructose during exercise
Jentjens, R. L. P. G., Moseley, L., Waring, R. H., Harding, L. K., & Jeukendrup, A. E. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00974.2003 · Cited by 310
Jeukendrup, A. E., & Jentjens, R. (2000) · Sports Medicine · doi:10.2165/00007256-200029060-00004 · Cited by 279
“O2max).([10,12,13]) In many experimental conditions, the entrapment of (14)CO2 or (13)CO2 in the bicarbonate pool may cause a marked underestimation of the true exogenous CHO oxidation, especially during the first hour of exercise.”
BackgroundJentjens, R. L. P. G., & Jeukendrup, A. E. (2005) · British Journal of Nutrition · doi:10.1079/bjn20041368 · Cited by 171
“Recovery of 13CO2 from oxidation will approach 100 % after 60 min of exercise when dilution in the bicarbonate pool becomes negligible (Robert et al. 1987; Pallikarakis et al. 1991).”
BackgroundHigh Oxidation Rates from Combined Carbohydrates Ingested during Exercise
JENTJENS, R. L. P. G., ACHTEN, J., & JEUKENDRUP, A. E. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000139796.07843.1d · Cited by 153
Exogenous carbohydrate oxidation during ultraendurance exercise
Jeukendrup, A. E., Moseley, L., Mainwaring, G. I., Samuels, S., Perry, S., & Mann, C. H. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00981.2004 · Cited by 147
Metadata
- Authors
- Robert, J. J., Koziet, J., Chauvet, D., Darmaun, D., Desjeux, J. F., & Young, V. R.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1987-11-01
- Volume
- 63
- Issue
- 5
- Pages
- 1725-1732
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2411077968
- Cited by
- 91
- References
- 0
- FWCI
- 0.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of 13C-labeled glucose for estimating glucose oxidation: some design considerations. https://app.cochat.ai/papers/10.1152/jappl.1987.63.5.1725
- The paper
- Robert, J. J., Koziet, J., Chauvet, D., Darmaun, D., Desjeux, J. F., & Young, V. R. (1987). Use of 13C-labeled glucose for estimating glucose oxidation: some design considerations. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1987.63.5.1725
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.