The DOI matches its Crossref record.
Regulation of end-expiratory lung volume during exercise
Abstract
We determined the effects of exercise on active expiration and end-expiratory lung volume (EELV) during steady-state exercise in 13 healthy subjects. We also addressed the questions of what affects active expiration during exercise. Exercise effects on EELV were determined by a He-dilution technique and verified by changes in end-expiratory esophageal pressure. We also used abdominal pressure-volume loops to determine active expiration. EELV was reduced with increasing exercise intensity. EELV was reduced significantly during even mild steady-state exercise and during heavy exercise decreased an average of 0.71 +/- 0.3 liter. Dynamic lung compliance was reduced 30-50%; EELV remained greater than closing volume. Changing the resistance to airflow (via SF6-O2 or He-O2 breathing) during steady-state exercise changed the peak gastric and esophageal pressure generation during expiration but did not alter EELV; breathing through the mouthpiece produced similar effects during exercise. EELV was significantly reduced in the supine position. With supine exercise active expiration was not elicited, and EELV remained the same as in supine rest. With CO2-driven hyperpnea (7-70 l/min), EELV remained unchanged from resting levels, whereas during exercise, at similar minute ventilation (VE) values EELV was consistently decreased. At the same VE, treadmill running caused an increase in tonic gastric pressure and greater reductions in EELV than either walking or cycling. We conclude that both the exercise stimulus and the resultant hyperpnea stimulate active expiration and a reduced FRC. This new EELV is preserved in the face of moderate changes in mechanical time constants of the lung. This reduced EELV during exercise aids inspiration by optimizing diaphragmatic length and permitting elastic recoil of the chest wall.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ATS/ACCP statement on cardiopulmonary exercise testing
(2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.167.2.211 · Cited by 3,026
Respiratory mechanics during exercise in endurance‐trained men and women
Guenette, J. A., Witt, J. D., McKenzie, D. C., Road, J. D., & Sheel, A. W. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2006.126466 · Cited by 247
Smaller lungs in women affect exercise hyperpnea
McClaran, S. R., Harms, C. A., Pegelow, D. F., & Dempsey, J. A. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.84.6.1872 · Cited by 238
Self-citationDyspnea and Activity Limitation in COPD: Mechanical Factors
O'Donnell, D. E., & Laveneziana, P. (2007) · COPD: Journal of Chronic Obstructive Pulmonary Disease · doi:10.1080/15412550701480455 · Cited by 220
Inspiratory Capacity during Exercise: Measurement, Analysis, and Interpretation
Guenette, J. A., Chin, R. C., Cory, J. M., Webb, K. A., & O'Donnell, D. E. (2013) · Pulmonary Medicine · doi:10.1155/2013/956081 · Cited by 203
Metadata
- Authors
- Henke, K. G., Sharratt, M., Pegelow, D., & Dempsey, J. A.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1988-01-01
- Volume
- 64
- Issue
- 1
- Pages
- 135-146
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1842694608
- Cited by
- 256
- References
- 0
- FWCI
- 13.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Regulation of end-expiratory lung volume during exercise. https://app.cochat.ai/papers/10.1152/jappl.1988.64.1.135
- The paper
- Henke, K. G., Sharratt, M., Pegelow, D., & Dempsey, J. A. (1988). Regulation of end-expiratory lung volume during exercise. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1988.64.1.135
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.