Mechanism of exercise-induced hypoxemia in horses
The DOI matches its Crossref record.
Abstract
Arterial hypoxemia has been reported in horses during heavy exercise, but its mechanism has not been determined. With the use of the multiple inert gas elimination technique, we studied five horses, each on two separate occasions, to determine the physiological basis of the hypoxemia that developed during horizontal treadmill exercise at speeds of 4, 10, 12, and 13–14 m/s. Mean, blood temperature-corrected, arterial PO2 fell from 89.4 Torr at rest to 80.7 and 72.1 Torr at 12 and 13–14 m/s, respectively, whereas corresponding PaCO2 values were 40.3, 40.3, and 39.2 Torr. Alveolar-arterial PO2 differences (AaDO2) thus increased from 11.4 Torr at rest to 24.9 and 30.7 Torr at 12 and 13–14 m/s. In 8 of the 10 studies there was no change in ventilation-perfusion (VA/Q) relationships with exercise (despite bronchoscopic evidence of airway bleeding in 3) and total shunt was always less than 1% of the cardiac output. Below 10 m/s, the AaDO2 was due only to VA/Q mismatch, but at higher speeds, diffusion limitation of O2 uptake was increasingly evident, accounting for 76% of the AaDO2 at 13–14 m/s. Most of the exercise-induced hypoxemia is thus the result of diffusion limitation with a smaller contribution from VA/Q inequality and essentially none from shunting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Poole, D. C., & Jones, A. M. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100072 · Cited by 514
Ruina, A., Bertram, J. E. A., & Srinivasan, M. (2005) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2005.04.004 · Cited by 433
Evolution of Air Breathing: Oxygen Homeostasis and the Transitions from Water to Land and Sky
Hsia, C. C. W., Schmitz, A., Lambertz, M., Perry, S. F., & Maina, J. N. (2013) · Comprehensive Physiology · doi:10.1002/cphy.c120003 · Cited by 341
Invited Review: Pulmonary capillary stress failure
West, J. B. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.6.2483 · Cited by 260
Intense exercise impairs the integrity of the pulmonary blood-gas barrier in elite athletes.
Hopkins, S. R., Schoene, R. B., Henderson, W. R., Spragg, R. G., Martin, T. R., & West, J. B. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.155.3.9116992 · Cited by 234
The relationship between mechanical work and energy expenditure of locomotion in horses
Minetti, A. E., Ardigò, L. P., Reinach, E., & Saibene, F. (1999) · Journal of Experimental Biology · doi:10.1242/jeb.202.17.2329 · Cited by 228
Control of Breathing During Exercise
Forster, H. V., Haouzi, P., & Dempsey, J. A. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100045 · Cited by 221
Lung Structure and the Intrinsic Challenges of Gas Exchange
Hsia, C. C. W., Hyde, D. M., & Weibel, E. R. (2016) · Comprehensive Physiology · doi:10.1002/cphy.c150028 · Cited by 191
STRUCTURE, STRENGTH, FAILURE, AND REMODELING OF THE PULMONARY BLOOD-GAS BARRIER
West, J. B., & Mathieu-Costello, O. (1999) · Annual Review of Physiology · doi:10.1146/annurev.physiol.61.1.543 · Cited by 180
Guidelines for animal exercise and training protocols for cardiovascular studies
Poole, D. C., Copp, S. W., Colburn, T. D., Craig, J. C., Allen, D. L., Sturek, M., O’Leary, D. S., Zucker, I. H., & Musch, T. I. (2020) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00697.2019 · Cited by 139
Metadata
- Authors
- Wagner, P. D., Gillespie, J. R., Landgren, G. L., Fedde, M. R., Jones, B. W., DeBowes, R. M., Pieschl, R. L., & Erickson, H. H.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1989-03-01
- Volume
- 66
- Issue
- 3
- Pages
- 1227-1233
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2411735118
- Cited by
- 209
- References
- 0
- FWCI
- 13.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.