The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Invited Review: Pulmonary capillary stress failure
Abstract
The pulmonary blood-gas barrier is an extraordinary bioengineering structure because of its vast area but extreme thinness. Despite this, almost no attention has been given to its mechanical properties. The remarkable area and thinness come about because gas exchange occurs by passive diffusion. However, the barrier also needs to be immensely strong to withstand the very high stresses in the capillary wall when capillary pressure rises during exercise. The strength of the thin region of the barrier comes from type IV collagen in the basement membranes. When the stresses in the capillary walls rise to high levels, ultrastructural changes occur in the barrier, a condition known as stress failure. Physiological conditions that alter the properties of the barrier include severe exercise in elite human athletes. Animals that have been selectively bred for high aerobic activity, such as Thoroughbred racehorses, consistently break their pulmonary capillaries during galloping. Pathophysiological conditions causing stress failure include high-altitude pulmonary edema and overinflation of the lung, which frequently occurs with mechanical ventilation. Remodeling of the capillary wall occurs in response to increased wall stress in diseases such as mitral stenosis. The barrier is able to maintain its extreme thickness with sufficient strength as a result of continual regulation of its wall structure. How it does this is a central problem in lung biology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2000) · New England Journal of Medicine · doi:10.1056/nejm200005043421801 · Cited by 12,941
Textbook of Medical Physiology
(1966) · Annals of Internal Medicine · doi:10.7326/0003-4819-64-6-1363_2 · Cited by 9,749
Sorokin, S. P. (1983) · Histology · doi:10.1007/978-1-349-06859-3_23 · Cited by 1,782
Molecular architecture of basement membranes
Yurchenco, P. D., & Schittny, J. C. (1990) · The FASEB Journal · doi:10.1096/fasebj.4.6.2180767 · Cited by 944
A Network Model for the Organization of Type IV Collagen Molecules in Basement Membranes
TIMPL, R., WIEDEMANN, H., DELDEN, V., FURTHMAYR, H., & KUHN, K. (1981) · European Journal of Biochemistry · doi:10.1111/j.1432-1033.1981.tb05690.x · Cited by 897
The normal human lung: ultrastructure and morphometric estimation of diffusion capacity
Gehr, P., Bachofen, M., & Weibel, E. R. (1978) · Respiration Physiology · doi:10.1016/0034-5687(78)90104-4 · Cited by 650
(1987) · Journal of Critical Care · doi:10.1016/0883-9441(87)90024-4 · Cited by 572
Exercise‐induced arterial hypoxaemia in healthy human subjects at sea level.
Dempsey, J. A., Hanson, P. G., & Henderson, K. S. (1984) · The Journal of Physiology · doi:10.1113/jphysiol.1984.sp015412 · Cited by 555
Stress failure in pulmonary capillaries
West, J. B., Tsukimoto, K., Mathieu-Costello, O., & Prediletto, R. (1991) · Journal of Applied Physiology · doi:10.1152/jappl.1991.70.4.1731 · Cited by 512
Self-citationPulmonary gas exchange in humans exercising at sea level and simulated altitude
Wagner, P. D., Gale, G. E., Moon, R. E., Torre-Bueno, J. R., Stolp, B. W., & Saltzman, H. A. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.61.1.260 · Cited by 487
Cited by
Cytoskeletal regulation of pulmonary vascular permeability
Dudek, S. M., & Garcia, J. G. N. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.4.1487 · Cited by 985
Permeability of the Endothelial Barrier: Identifying and Reconciling Controversies
Claesson-Welsh, L., Dejana, E., & McDonald, D. M. (2021) · Trends in Molecular Medicine · doi:10.1016/j.molmed.2020.11.006 · Cited by 631
Physical and biological triggers of ventilator-induced lung injury and its prevention
Gattinoni, L., Carlesso, E., Cadringher, P., Valenza, F., Vagginelli, F., & Chiumello, D. (2003) · European Respiratory Journal · doi:10.1183/09031936.03.00021303 · Cited by 329
Perspective on Lung Injury and Recruitment: A Skeptical Look at the Opening and Collapse Story
Hubmayr, R. D. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2001080-01cp · Cited by 312
Low Tidal Volume Reduces Epithelial and Endothelial Injury in Acid-injured Rat Lungs
FRANK, J. A., GUTIERREZ, J. A., JONES, K. D., ALLEN, L., DOBBS, L., & MATTHAY, M. A. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.165.2.2108087 · Cited by 284
Metadata
- Authors
- West, J. B.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2000-12-01
- Volume
- 89
- Issue
- 6
- Pages
- 2483-2489
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1902593427
- Cited by
- 260
- References
- 33
- FWCI
- 7.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Invited Review: Pulmonary capillary stress failure. https://app.cochat.ai/papers/10.1152/jappl.2000.89.6.2483
- The paper
- West, J. B. (2000). Invited Review: Pulmonary capillary stress failure. Journal of Applied Physiology. https://doi.org/10.1152/jappl.2000.89.6.2483
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.