Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 175

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Influence of work rate on ventilatory and gas exchange kinetics

Casaburi, R., Barstow, T. J., Robinson, T., Wasserman, K. · 1989 · Journal of Applied Physiology

Abstract

A linear system has the property that the kinetics of response do not depend on the stimulus amplitude. We sought to determine whether the responses of O2 uptake (VO2), CO2 output (VCO2), and ventilation (VE) in the transition between loadless pedaling and higher work rates are linear in this respect. Four healthy subjects performed a total of 158 cycle ergometer tests in which 10 min of exercise followed unloaded pedaling. Each subject performed three to nine tests at each of seven work rates, spaced evenly below the maximum the subject could sustain. VO2, VCO2, and VE were measured breath by breath, and studies at the same work rate were time aligned and averaged. Computerized nonlinear regression techniques were used to fit a single exponential and two more complex expressions to each response time course. End-exercise blood lactate was determined at each work rate. Both VE and VO2 kinetics were markedly slower at work rates associated with sustained blood lactate elevations. A tendency was also detected for VO2 (but not VE) kinetics to be slower as work rate increased for exercise intensities not associated with lactic acidosis (P less than 0.01). VO2 kinetics at high work rates were well characterized by the addition of a slower exponential component to the faster component, which was seen at lower work rates. In contrast, VCO2 kinetics did not slow at the higher exercise intensities; this may be the result of the coincident influence of several sources of CO2 related to lactic acidosis. These findings provide guidance for interpretation of ventilatory and gas exchange kinetics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1989.67.2.547

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 175

Metadata

Authors
Casaburi, R., Barstow, T. J., Robinson, T., & Wasserman, K.
Venue
Journal of Applied Physiology
Published
1989-08-01
Volume
67
Issue
2
Pages
547-555
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2099815936
Cited by
175
References
2
FWCI
15.11
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Influence of work rate on ventilatory and gas exchange kinetics. https://app.cochat.ai/papers/10.1152/jappl.1989.67.2.547
The paper
Casaburi, R., Barstow, T. J., Robinson, T., & Wasserman, K. (1989). Influence of work rate on ventilatory and gas exchange kinetics. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1989.67.2.547

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.