Initial blood pressure fall on stand up and exercise explained by changes in total peripheral resistance
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
To elucidate the underlying mechanisms of the initial fall in blood pressure on standing upright from the supine position, we measured the beat-to-beat changes in intra-arterial pressure in eight healthy male subjects in response to standing. Changes in stroke volume, cardiac output, and total peripheral resistance were computed from the pressure waveform using a pulse contour method. To determine possible mechanisms for the changes observed on standing, similar measures were made on passive tilting and a brief (3-s) bout of cycle exercise. Standing elicited a transient 25% (23-mmHg) fall in mean blood pressure as a result of a 36% fall in total peripheral resistance. Head-up tilt elicited a gradual change in haemodynamic parameters, which reached plateau levels in 20-30 s. Cycling elicited a transient 17% (18-mmHg) fall in blood pressure and a 41% fall in total peripheral resistance. In addition, we measured right atrial and esophageal pressures in two subjects on standing and cycling and found a 10- to 15-mmHg rise in right atrial pressure without a corresponding change in esophageal pressure. This points to the cardiopulmonary reflex as the primary effector of peripheral vasodilation, but we cannot exclude the possibility that 1) local metabolic vasodilation and 2) central command-mediated cholinergic vasodilation contributed to the fall in vascular resistance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goodwin, G. M., McCloskey, D. I., & Mitchell, J. H. (1972) · The Journal of Physiology · doi:10.1113/jphysiol.1972.sp009979 · Cited by 680
Thermodilution cardiac output: A critical analysis and review of the literature
Levett, J. M., & Replogle, R. L. (1979) · Journal of Surgical Research · doi:10.1016/0022-4804(79)90159-8 · Cited by 241
HOLMGREN, A. (1956) · PubMed · Cited by 207
Effect of a brief contraction of forearm muscles on forearm blood flow
Corcondilas, A., Koroxenidis, G. T., & Shepherd, J. T. (1964) · Journal of Applied Physiology · doi:10.1152/jappl.1964.19.1.142 · Cited by 155
Effect of different degrees of tilt on cardiac output, heart rate, and blood pressure in normal man.
Tuckman, J., & Shillingford, J. P. (1966) · Heart · doi:10.1136/hrt.28.1.32 · Cited by 101
Adams, L. M., Guz, A., Innes, J. A., & Murphy, K. (1987) · The Journal of Physiology · doi:10.1113/jphysiol.1987.sp016393 · Cited by 96
Grassi, G. M., Gavazzi, C., Cesura, A. M., Picotti, G. B., & Mancia, G. (1985) · Clinical Science · doi:10.1042/cs0680503 · Cited by 46
Cited by
Vinik, A. I., Maser, R. E., Mitchell, B. D., & Freeman, R. (2003) · Diabetes Care · doi:10.2337/diacare.26.5.1553 · Cited by 2,044
Computation of aortic flow from pressure in humans using a nonlinear, three-element model
Wesseling, K. H., Jansen, J. R., Settels, J. J., & Schreuder, J. J. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.74.5.2566 · Cited by 1,137
Self-citationFifteen years experience with finger arterial pressure monitoring: assessment of the technology
Imholz, B. (1998) · Cardiovascular Research · doi:10.1016/s0008-6363(98)00067-4 · Cited by 834
Self-citationAssessment of cardiac output from systemic arterial pressure in humans
Romano, S. M., & Pistolesi, M. (2002) · Critical Care Medicine · doi:10.1097/00003246-200208000-00027 · Cited by 616
van Beek, A. H., Claassen, J. A., Rikkert, M. G. O., & Jansen, R. W. (2008) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2008.13 · Cited by 485
“The reduction in BP (of approximately 25%), resulting from an immediate and marked decrease in total peripheral resistance upon standing, is presumably caused by cardiopulmonary baroreflex mechanisms (Sprangers et al, 1991).”
Initial orthostatic hypotension: review of a forgotten condition
Wieling, W., Krediet, C. T. P., van Dijk, N., Linzer, M., & Tschakovsky, M. E. (2007) · Clinical Science · doi:10.1042/cs20060091 · Cited by 374
Self-citationGANZEBOOM, K. S., MAIRUHU, G., REITSMA, J. B., LINZER, M., WIELING, W., & VAN DIJK, N. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00595.x · Cited by 375
Self-citationSyncope, cerebral perfusion, and oxygenation
Van Lieshout, J. J., Wieling, W., Karemaker, J. M., & Secher, N. H. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00260.2002 · Cited by 365
Self-citationHemodynamic Response to the Upright Posture
Smith, J. J., Porth, C. M., & Erickson, M. (1994) · The Journal of Clinical Pharmacology · doi:10.1002/j.1552-4604.1994.tb04977.x · Cited by 319
Barbieri, R., Matten, E. C., Alabi, A. A., & Brown, E. N. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00482.2003 · Cited by 307
Dynamic Regulation of Middle Cerebral Artery Blood Flow Velocity in Aging and Hypertension
Lipsitz, L. A., Mukai, S., Hamner, J., Gagnon, M., & Babikian, V. (2000) · Stroke · doi:10.1161/01.str.31.8.1897 · Cited by 276
Assessment of cardiovascular autonomic function
Freeman, R. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.09.027 · Cited by 262
Nexfin Noninvasive Continuous Blood Pressure Validated Against Riva-Rocci/Korotkoff
Eeftinck Schattenkerk, D. W., van Lieshout, J. J., van den Meiracker, A. H., Wesseling, K. R., Blanc, S., Wieling, W., van Montfrans, G. A., Settels, J. J., Wesseling, K. H., & Westerhof, B. E. (2009) · American Journal of Hypertension · doi:10.1038/ajh.2008.368 · Cited by 222
Self-citationIntegration of Cardiovascular Control Systems in Dynamic Exercise
Rowell, L. B., O'Leary, D. S., & Kellogg, D. L. (1996) · Comprehensive Physiology · doi:10.1002/cphy.cp120117 · Cited by 217
Continuous finger arterial pressure: Utility in the cardiovascular laboratory
Imholz, B. P. M., Wieling, W., Langewouters, G. J., & van Montfrans, G. A. (1991) · Clinical Autonomic Research · doi:10.1007/bf01826057 · Cited by 181
Self-citationCircadian Profile of Systemic Hemodynamics
Veerman, D. P., Imholz, B. P. M., Wieling, W., Wesseling, K. H., & van Montfrans, G. A. (1995) · Hypertension · doi:10.1161/01.hyp.26.1.55 · Cited by 176
Self-citationTesting the autonomic nervous system
(2013) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-52902-2.00007-2 · Cited by 161
Effects of benzodiazepines on orthostatic blood pressure in older people
Rivasi, G., Kenny, R. A., Ungar, A., & Romero-Ortuno, R. (2020) · European Journal of Internal Medicine · doi:10.1016/j.ejim.2019.10.032 · Cited by 41
Metadata
- Authors
- Sprangers, R. L., Wesseling, K. H., Imholz, A. L., Imholz, B. P., & Wieling, W.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1991-02-01
- Volume
- 70
- Issue
- 2
- Pages
- 523-530
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2164620593
- Cited by
- 179
- References
- 7
- FWCI
- 4.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.