CoChat

An apparatus to measure in vivo biomechanical behavior of dorsi- and plantarflexors of mouse ankle

Ashton-Miller, J. A., He, Y., Kadhiresan, V. A., McCubbrey, D. A., Faulkner, J. A. · 1992 · Journal of Applied Physiology
Cited by 76

The DOI matches its Crossref record.

Abstract

We developed an apparatus to quantify the biomechanical behavior of the dorsi- and plantarflexor muscles of the ankle of an anesthetized mouse. When the dorsi- or plantarflexor muscle group is activated by electrical stimulation of either the peroneal or tibial nerve, the apparatus measures the moment developed about the ankle during isometric, isovelocity shortening, or isovelocity lengthening contractions. Displacements may be performed over the full 105 degrees range of ankle motion with an angular resolution of 0.09 degrees. Bidirectional isovelocity ramps in ankle angle up to 1,100 degrees/s are possible and are equivalent to maximum velocities of 2.3 fiber lengths/s (Lf/s) for the fibers in tibialis anterior muscle and 11.9 Lf/s for those in gastrocnemius muscle. During single contractions of the dorsi- and plantarflexor muscle groups at 37 degrees C and with both knee and ankle joint at 90 degrees neutral position, the isometric tetanic force developed was 1.4 and 3.3 N, power output at 2.2 Lf/s was 3.1 and 5.9 mW, and power absorption at 0.5 Lf/s was 4.9 and 9.0 mW, respectively. These values are in reasonable agreement with data from the same muscle groups tested in situ. We conclude that the apparatus provides valid measurements of force and power of the dorsi- and plantarflexor muscle groups.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1992.72.3.1205

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 76

Metadata

Authors
Ashton-Miller, J. A., He, Y., Kadhiresan, V. A., McCubbrey, D. A., & Faulkner, J. A.
Venue
Journal of Applied Physiology
Published
1992-03-01
Volume
72
Issue
3
Pages
1205-1211
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2267480210
Cited by
76
References
0
FWCI
1.25
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An apparatus to measure in vivo biomechanical behavior of dorsi- and plantarflexors of mouse ankle. https://app.cochat.ai/papers/10.1152/jappl.1992.72.3.1205
The paper
Ashton-Miller, J. A., He, Y., Kadhiresan, V. A., McCubbrey, D. A., & Faulkner, J. A. (1992). An apparatus to measure in vivo biomechanical behavior of dorsi- and plantarflexors of mouse ankle. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1992.72.3.1205

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.