An apparatus to measure in vivo biomechanical behavior of dorsi- and plantarflexors of mouse ankle
The DOI matches its Crossref record.
Abstract
We developed an apparatus to quantify the biomechanical behavior of the dorsi- and plantarflexor muscles of the ankle of an anesthetized mouse. When the dorsi- or plantarflexor muscle group is activated by electrical stimulation of either the peroneal or tibial nerve, the apparatus measures the moment developed about the ankle during isometric, isovelocity shortening, or isovelocity lengthening contractions. Displacements may be performed over the full 105 degrees range of ankle motion with an angular resolution of 0.09 degrees. Bidirectional isovelocity ramps in ankle angle up to 1,100 degrees/s are possible and are equivalent to maximum velocities of 2.3 fiber lengths/s (Lf/s) for the fibers in tibialis anterior muscle and 11.9 Lf/s for those in gastrocnemius muscle. During single contractions of the dorsi- and plantarflexor muscle groups at 37 degrees C and with both knee and ankle joint at 90 degrees neutral position, the isometric tetanic force developed was 1.4 and 3.3 N, power output at 2.2 Lf/s was 3.1 and 5.9 mW, and power absorption at 0.5 Lf/s was 4.9 and 9.0 mW, respectively. These values are in reasonable agreement with data from the same muscle groups tested in situ. We conclude that the apparatus provides valid measurements of force and power of the dorsi- and plantarflexor muscle groups.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Grounds, M. D., Radley, H. G., Lynch, G. S., Nagaraju, K., & De Luca, A. (2008) · Neurobiology of Disease · doi:10.1016/j.nbd.2008.03.008 · Cited by 344
Use of Autologous Platelet-rich Plasma to Treat Muscle Strain Injuries
Hammond, J. W., Hinton, R. Y., Curl, L. A., Muriel, J. M., & Lovering, R. M. (2009) · The American Journal of Sports Medicine · doi:10.1177/0363546508330974 · Cited by 301
3D Bioprinted Human Skeletal Muscle Constructs for Muscle Function Restoration
Kim, J. H., Seol, Y.-J., Ko, I. K., Kang, H.-W., Lee, Y. K., Yoo, J. J., Atala, A., & Lee, S. J. (2018) · Scientific Reports · doi:10.1038/s41598-018-29968-5 · Cited by 290
Injury to muscle fibres after single stretches of passive and maximally stimulated muscles in mice.
Brooks, S. V., Zerba, E., & Faulkner, J. A. (1995) · The Journal of Physiology · doi:10.1113/jphysiol.1995.sp020980 · Cited by 288
Self-citationZhang, Z., Li, J., Guan, D., Liang, C., Zhuo, Z., Liu, J., Lu, A., Zhang, G., & Zhang, B. (2018) · Journal of Cachexia, Sarcopenia and Muscle · doi:10.1002/jcsm.12281 · Cited by 188
“In situ muscle functional testing was performed following the established protocol.(27) The animals were anaesthetised with isophorone gas inhale system and then placed on a 37°C”
MethodMaas, H., Baan, G. C., & Huijing, P. A. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00055-0 · Cited by 180
Muscle function and protein metabolism after initiation of eccentric contraction-induced injury
Lowe, D. A., Warren, G. L., Ingalls, C. P., Boorstein, D. B., & Armstrong, R. B. (1995) · Journal of Applied Physiology · doi:10.1152/jappl.1995.79.4.1260 · Cited by 170
Estradiol effect on anterior crural muscles-tibial bone relationship and susceptibility to injury
Warren, G. L., Lowe, D. A., Inman, C. L., Orr, O. M., Hogan, H. A., Bloomfield, S. A., & Armstrong, R. B. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.80.5.1660 · Cited by 56
Stieglitz, T., Schuettler, M., Schneider, A., Valderrama, E., & Navarro, X. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.819793 · Cited by 19
Chugh, D., Iyer, C. C., Bobbili, P., Blatnik, A. J., Kaspar, B. K., Meyer, K., Burghes, A. H., Clark, B. C., & Arnold, W. D. (2021) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2021.01.012 · Cited by 17
Metadata
- Authors
- Ashton-Miller, J. A., He, Y., Kadhiresan, V. A., McCubbrey, D. A., & Faulkner, J. A.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1992-03-01
- Volume
- 72
- Issue
- 3
- Pages
- 1205-1211
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2267480210
- Cited by
- 76
- References
- 0
- FWCI
- 1.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.