Noninvasive cardiac output measurement by arterial pulse analysis compared with inert gas rebreathing
The DOI matches its Crossref record.
Abstract
Noninvasive cardiac output (CO) measured by arterial pulse analysis was compared with that measured by inert gas rebreathing in six healthy male volunteers. Pulse contour analysis was applied to the pressure wave output of a Finapres, which noninvasively measures continuous arterial pressure in a finger. Data were collected before, during, and after a 10-day 6 degrees head-down tilt experiment. Intravenous saline loading and lower body negative pressure stimuli varied CO over 2.8–9.6 l/min, as measured by the rebreathing technique. Because pulse contour provides only relative changes in CO, to obtain absolute values it must be calibrated against another measurement. Pulse contour data were calibrated every measurement day against the mean of two to four control rebreathing CO measurements before the lower body negative pressure or intravenous saline loading stimuli. Using one averaged calibration factor per subject for a total of 27 days, we compared the results of both methods. The linear regression between pulse contour (Pc CO) and rebreathing CO (Rebr CO) was Pc CO = 0.15 + 0.98(Rebr CO) (r = 0.96). The standard deviation of the difference of the two methods was 0.5 l/min (n = 205), excluding data used for calibration. By monitoring pulse contour CO before and during rebreathing, the rebreathing maneuver itself was shown to produce a substantial increase in CO that was mainly related to an increase in heart rate.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rossi, P., Andriesse, G. I., Oey, P. L., Wieneke, G. H., Roelofs, J. M. M., & Akkermans, L. M. A. (1998) · Journal of the Neurological Sciences · doi:10.1016/s0022-510x(98)00276-7 · Cited by 767
Assessment of cardiac output from systemic arterial pressure in humans
Romano, S. M., & Pistolesi, M. (2002) · Critical Care Medicine · doi:10.1097/00003246-200208000-00027 · Cited by 616
Non‐invasive pulsatile arterial pressure and stroke volume changes from the human finger
Bogert, L. W. J., & van Lieshout, J. J. (2005) · Experimental Physiology · doi:10.1113/expphysiol.2005.030262 · Cited by 413
Cardiovascular management of septic shock
Dellinger, R. P. (2003) · Critical Care Medicine · doi:10.1097/01.ccm.0000057403.73299.a6 · Cited by 369
Sugawara, J., Tanabe, T., Miyachi, M., Yamamoto, K., Takahashi, K., Iemitsu, M., Otsuki, T., Homma, S., Maeda, S., Ajisaka, R., et al. (2003) · Acta Physiologica Scandinavica · doi:10.1046/j.0001-6772.2003.01211.x · Cited by 230
Wilhelm, F. H., Kochar, A. S., Roth, W. T., & Gross, J. J. (2001) · Biological Psychology · doi:10.1016/s0301-0511(01)00113-2 · Cited by 223
“These measurements have been previously validated (Gratz et al., 1992; Imholz et al., 1990; Stok et al., 1993).”
Effects of Leg Blood Flow Restriction during Walking on Cardiovascular Function
RENZI, C. P., TANAKA, H., & SUGAWARA, J. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181bdb454 · Cited by 193
“Although the model flow methods for estimating change in cardiac output have been validated during various conditions including cycling exercise (18,19,24), it may not provide absolute levels of cardiac output.”
MethodInfluentialPhysiologic instability in panic disorder and generalized anxiety disorder
Wilhelm, F. H., Trabert, W., & Roth, W. T. (2001) · Biological Psychiatry · doi:10.1016/s0006-3223(00)01000-3 · Cited by 180
Noninvasive continuous hemodynamic monitoring
Truijen, J., van Lieshout, J. J., Wesselink, W. A., & Westerhof, B. E. (2012) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-012-9375-8 · Cited by 161
“Noninvasive and (semi-)continuous tracking of changes in SV can be accomplished by thoracic electrical impedance [80–82], ultrasound [14, 83] and by pulse contour analysis [84–88].”
Backgroundvan Lieshout, J. J., ten Harkel, A. D. J., & Wieling, W. (2000) · Clinical Autonomic Research · doi:10.1007/bf02291388 · Cited by 144
Neural circulatory control in vasovagal syncope
VAN LIESHOUT, J. J., WIELING, W., & KAREMAKER, J. M. (1997) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1997.tb03901.x · Cited by 52
Self-citation
Metadata
- Authors
- Stok, W. J., Baisch, F., Hillebrecht, A., Schulz, H., Meyer, M., & Karemaker, J. M.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1993-06-01
- Volume
- 74
- Issue
- 6
- Pages
- 2687-2693
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2206179796
- Cited by
- 98
- References
- 0
- FWCI
- 3.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.