Assessment of methacholine-induced airway constriction by ultrafast high-resolution computed tomography
The DOI matches its Crossref record.
Abstract
Assessment of changes in airway dimensions during bronchoconstriction is conventionally based on measurements of respiratory mechanics. We evaluated the efficacy of ultrafast high-resolution computed tomography (UHRCT) to directly determine the dynamic changes in cross-sectional area (CSA) of airways in response to methacholine (MCh). UHRCT scans were obtained at functional residual capacity before (baseline) and after intravenous bolus injections of MCh (10(-8.5)-10(-7.0) mol/kg) to seven mechanically ventilated pigs. Changes in CSA of bronchi of varying baseline size (1–10 mm diam) were determined by using a customized image processing software package (VIDA) based on a user-directed computer-adjusted edge-finding algorithm. MCh induced dose-dependent decreases in CSA, which were paralleled by increases in airway opening pressure at higher doses of MCh; at lower doses of MCh, decreases in CSA of smaller airways were detected without concomitant changes in airway opening pressure. Changes in CSA were heterogeneous and variable, especially in the smaller airway ranges. The results of the present study support the concept that UHRCT can be used in conjunction with bolus challenges to effectively determine dose-response changes in airway caliber in both large and small airways. This technique provides data that may not be reflected by conventional lung function measurements and, hence, is a useful tool to study airway reactivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Automatic lung segmentation for accurate quantitation of volumetric X-ray CT images
Hu, S., Hoffman, E. A., & Reinhardt, J. M. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.929615 · Cited by 940
Self-citationComputed Tomographic Measurements of Airway Dimensions and Emphysema in Smokers
NAKANO, Y., MURO, S., SAKAI, H., HIRAI, T., CHIN, K., TSUKINO, M., NISHIMURA, K., ITOH, H., PARÉ, P. D., HOGG, J. C., et al. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.3.9907120 · Cited by 695
Airway smooth muscle dynamics: a common pathway of airway obstruction in asthma
An, S. S., Bai, T. R., Bates, J. H. T., Black, J. L., Brown, R. H., Brusasco, V., Chitano, P., Deng, L., Dowell, M., Eidelman, D. H., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00112606 · Cited by 383
Impaired mucus detachment disrupts mucociliary transport in a piglet model of cystic fibrosis
Hoegger, M. J., Fischer, A. J., McMenimen, J. D., Ostedgaard, L. S., Tucker, A. J., Awadalla, M. A., Moninger, T. O., Michalski, A. S., Hoffman, E. A., Zabner, J., et al. (2014) · Science · doi:10.1126/science.1255825 · Cited by 368
Self-citationLittle, S. A. (2002) · Thorax · doi:10.1136/thorax.57.3.247 · Cited by 230
Quantitative Assessment of Emphysema, Air Trapping, and Airway Thickening on Computed Tomography
KOLD Study Group, Lee, Y. K., Oh, Y.-M., Lee, J.-H., Kim, E. K., Lee, J. H., Kim, N., Seo, J. B., & Lee, S. D. (2008) · Lung · doi:10.1007/s00408-008-9071-0 · Cited by 220
“The software automatically detects the airway lumen and the inner and outer boundaries of the airway wall using a full-width-half-maximum method [20–23].”
MethodBROWN, R. H., SCICHILONE, N., MUDGE, B., DIEMER, F. B., PERMUTT, S., & TOGIAS, A. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.4.2007119 · Cited by 192
Orlandi, I., Moroni, C., Camiciottoli, G., Bartolucci, M., Pistolesi, M., Villari, N., & Mascalchi, M. (2005) · Radiology · doi:10.1148/radiol.2342040013 · Cited by 183
Accurate measurement of intrathoracic airways
Reinhardt, J. M., D'Souza, N., & Hoffman, E. A. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.650878 · Cited by 176
“A number of semiautomatic and automatic ROI measurement schemes have been proposed, including techniques based on estimates of the full-width–half-maximum (FWHM) gray level [4], [5], [9], [11], [12], methods using the intensity of the pixels in the lumen to compute the brightness-area product (BAP) [12], and approache…”
BackgroundMethodSelf-citationde Jong, P. A., Ottink, M. D., Robben, S. G. F., Lequin, M. H., Hop, W. C. J., Hendriks, J. J. E., Paré, P. D., & Tiddens, H. A. W. M. (2004) · Radiology · doi:10.1148/radiol.2312021393 · Cited by 171
“The software program constructed a profile of the Hounsfield units along the lines, and the observer calculated the cutoff level for the inner and the outer wall according to the full-width-at-half-maximum principle (14).”
MethodNew frontiers in CT imaging of airway disease
Grenier, P. A., Beigelman-Aubry, C., Fétita, C., Prêteux, F., Brauner, M. W., & Lenoir, S. (2002) · European Radiology · doi:10.1007/s00330-002-1342-1 · Cited by 166
“airways lumen [15, 17, 18, 20] and wall [20, 21] areas was very good only for bronchi measuring at least 2 mm in diameter.”
BackgroundMethodInfluential
Metadata
- Authors
- Amirav, I., Kramer, S. S., Grunstein, M. M., & Hoffman, E. A.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1993-11-01
- Volume
- 75
- Issue
- 5
- Pages
- 2239-2250
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2298785857
- Cited by
- 166
- References
- 0
- FWCI
- 1.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.