Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 159

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Examination of data normalization procedures for expressing peak VO2 data

Toth, M. J., Goran, M. I., Ades, P. A., Howard, D. B., Poehlman, E. T. · 1993 · Journal of Applied Physiology

Abstract

Peak O2 uptake (VO2) has traditionally been compared among individuals differing in body composition by dividing measured values (1/min) by fat-free mass (FFM) (i.e., ratio method). However, the ability of the ratio method to mathematically remove the confounding influence of FFM from peak VO2 has recently been questioned. Therefore, we compared the effectiveness of the ratio method vs. regression modeling to normalize peak VO2 in a large cohort of males and females for differences in FFM. Regression modeling adjusts peak VO2 according to the relationship derived from the regression of peak VO2 on FFM. Results showed that peak VO2 was 60% higher in males (3.53 +/- 1.01/min) than in females (2.22 +/- 0.6 l/min; P < 0.01). With the ratio method (i.e., peak VO2/FFM), peak VO2 was 15% higher in males (54.6 +/- 12 ml.kg FFM-1.min-1) than in females (47.4 +/- 11 ml.kg FFM-1.min-1; P < 0.01). In contrast, when a regression-based approach was employed to normalize values, no significant difference in adjusted peak VO2 was observed between males and females (3.04 +/- 0.9 vs. 3.01 +/- 1.0 l/min). In conclusion, dividing peak VO2 by FFM can produce spurious results, because this approach does not take into account the nonzero intercept. Therefore, a regression-based approach should be used to normalize peak VO2.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1993.75.5.2288

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 159

Metadata

Authors
Toth, M. J., Goran, M. I., Ades, P. A., Howard, D. B., & Poehlman, E. T.
Venue
Journal of Applied Physiology
Published
1993-11-01
Volume
75
Issue
5
Pages
2288-2292
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2103812813
Cited by
159
References
3
FWCI
15.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Examination of data normalization procedures for expressing peak VO2 data. https://app.cochat.ai/papers/10.1152/jappl.1993.75.5.2288
The paper
Toth, M. J., Goran, M. I., Ades, P. A., Howard, D. B., & Poehlman, E. T. (1993). Examination of data normalization procedures for expressing peak VO2 data. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1993.75.5.2288

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.