Nasal airway geometry: comparison between acoustic reflections and magnetic resonance scanning
The DOI matches its Crossref record.
Abstract
To evaluate the accuracy of the acoustic reflection (AR) technique for determination of nasal cavity cross-sectional areas, the area-distance function of both sides of the nose was determined in 10 subjects and compared with magnetic resonance imaging (MRI). Interindividual variation for the correlation between MRI and AR was seen, but in general the areas from 1 to 6 cm into the nasal cavity measured by AR were larger than areas measured by MRI, especially where the surface was most convoluted. The total volume for this region was 6.47 +/- 1.83 (SD) cm3 for AR and 5.65 +/- 1.34 cm3 for MRI. It was demonstrated that this could be due to errors in calculation of the areas on the basis of MRI and AR. In the posterior part of the nasal cavity and the epipharynx, there was a convincingly higher correlation between acoustic measurements and a scan perpendicular to the assumed geometrical axis of the epipharynx than between acoustic measurements and coronal scanning. This indicates that the sound axis roughly follows the geometrical axis. In a model of two tubes (nasal cavities) joined in a larger tube (the epipharynx), closure of the posterior part of the latter revealed that the contralateral nasal cavity is likely to cause overestimation of the posterior part of the epipharynx during AR compared with MRI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The diagnosis and management of rhinitis: An updated practice parameter
WALLACE, D., DYKEWICZ, M., BERNSTEIN, D., BLESSINGMOORE, J., COX, L., KHAN, D., LANG, D., NICKLAS, R., OPPENHEIMER, J., & PORTNOY, J. (2008) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2008.06.003 · Cited by 1,096
Objective monitoring of nasal patency and nasal physiology in rhinitis
Nathan, R. A., Eccles, R., Howarth, P. H., Steinsvåg, S. K., & Togias, A. (2005) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2004.12.015 · Cited by 206
“In contrast with measures of nasal airflow, which have indicated that such reciprocating cycles occur in as many as 80% of subjects,(87) acoustic rhinometry measures of nasal volume have revealed such changes in only 25% to 50% of subjects.(75,88,89) In one small study of 12 subjects without allergy, repeated measurem…”
Kimbell, J. S., Segal, R. A., Asgharian, B., Wong, B. A., Schroeter, J. D., Southall, J. P., Dickens, C. J., Brace, G., & Miller, F. J. (2007) · Journal of Aerosol Medicine · doi:10.1089/jam.2006.0531 · Cited by 174
“(46) MCA predicted by planar cross sections in each side of the CFD model showed reasonable agreement with AR measurements in plastic replicas of the same geometry (Table 2).”
Acoustic rhinometry in the evaluation of nasal obstruction
Roithmann, R., Cole, P., Chapnik, J., Shpirer, I., Hoffstein, V., & Zamel, N. (1995) · The Laryngoscope · doi:10.1288/00005537-199503000-00010 · Cited by 161
Comparison of Anatomic, Physiological, and Subjective Measures of the Nasal Airway
Lam, D. J., James, K. T., & Weaver, E. M. (2006) · American Journal of Rhinology · doi:10.2500/ajr.2006.20.2940 · Cited by 149
Metadata
- Authors
- Hilberg, O., Jensen, F. T., & Pedersen, O. F.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1993-12-01
- Volume
- 75
- Issue
- 6
- Pages
- 2811-2819
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2183014131
- Cited by
- 116
- References
- 0
- FWCI
- 3.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nasal airway geometry: comparison between acoustic reflections and magnetic resonance scanning. https://app.cochat.ai/papers/10.1152/jappl.1993.75.6.2811
- The paper
- Hilberg, O., Jensen, F. T., & Pedersen, O. F. (1993). Nasal airway geometry: comparison between acoustic reflections and magnetic resonance scanning. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1993.75.6.2811
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.