Multifrequency bioelectrical impedance estimates the distribution of body water
The DOI matches its Crossref record.
Abstract
Multifrequency bioelectrical impedance analysis was used to estimate the ratio of extracellular water (ECW) to total body water in subjects with end-stage renal disease. The body's resistance was measured at frequencies ranging from 1 kHz to 1 MHz. The impedance index (height2/resistance) determined at low frequency (5 kHz) correlated most closely with ECW (r = 0.886) using sodium bromide dilution as the standard of comparison. In contrast, the ratio of height squared to resistance determined at high frequency (500 kHz) correlated most closely with total body water (r = 0.974) using deuterium oxide dilution as the standard of comparison. The ratio of resistance at 500 kHz to resistance at 5 kHz was directly correlated (r = 0.767) with the ratio of ECW to total body water. Multifrequency bioelectrical impedance analysis may assist in the evaluation of body water distribution in endstage renal disease and other clinical disorders of fluid volume and/or distribution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Relationship of obesity and visceral adiposity with serum concentrations of CRP, TNF-α and IL-6
Park, H. S., Park, J. Y., & Yu, R. (2005) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2004.11.007 · Cited by 964
“0, Biospace, Seoul, Korea) [23], and their cross-sectional abdominal visceral and subcutaneous adipose tissue areas were measured by computed tomography (CT) on a Siemens Somaton Scanner (Erlangen, Germany) as described [24,25].”
MethodBioelectrical Impedance Methods for Noninvasive Health Monitoring: A Review
Bera, T. K. (2014) · Journal of Medical Engineering · doi:10.1155/2014/381251 · Cited by 407
Nutritional assessment with bioelectrical impedance analysis in maintenance hemodialysis patients.
Chertow, G. M., Lowrie, E. G., Wilmore, D. W., Gonzalez, J., Lew, N. L., Ling, J., Leboff, M. S., Gottlieb, M. N., Huang, W., & Zebrowski, B. (1995) · Journal of the American Society of Nephrology · doi:10.1681/asn.v6175 · Cited by 257
Self-citationA new technique for establishing dry weight in hemodialysis patients via whole body bioimpedance
Chamney, P. W., Krämer, M., Rode, C., Kleinekofort, W., & Wizemann, V. (2002) · Kidney International · doi:10.1046/j.1523-1755.2002.00377.x · Cited by 204
Liao, Y.-S., Li, H.-C., Lu, H.-K., Lai, C.-L., Wang, Y.-S., & Hsieh, K.-C. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17072595 · Cited by 48
“Subsequent validation studies on BIA8MF using tracer dilution as the reference method have suggested that BIA at a frequency of 500 kHz provides the best prediction of total body water [28,29], and a frequency of 5 kHz provides the best prediction for extracellular fluid [28].”
Method
Metadata
- Authors
- Cha, K., Chertow, G. M., Gonzalez, J., Lazarus, J. M., & Wilmore, D. W.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1995-10-01
- Volume
- 79
- Issue
- 4
- Pages
- 1316-1319
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1930766027
- Cited by
- 211
- References
- 0
- FWCI
- 1.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.