Comparison of Bioelectrical Impedance Analysis and Dual Energy X-ray Absorptiometry for Total and Segmental Bone Mineral Content with a Three-Compartment Model
Open accessAbstract
Modern bioelectrical impedance analysis (BIA) provides a wide range of body composition estimates such as fat mass (FM), lean body mass (LBM), and body water, using specific algorithms. Assuming that the fat free mass (FFM) and LBM can be accurately estimated by the 8-electrode BIA analyzer (BIA8MF; InBody230, Biospace), the bone mineral content (BMC) may be calculated by subtracting the LBM from the FFM estimates based on the three-compartment (3C) model. In this cross-sectional study, 239 healthy Taiwanese adults (106 male and 133 female) aged 20–45 years were recruited for BIA and dual-energy X-ray absorptiometry (DXA) measurements of the whole body and body segments, with DXA as the reference. The results showed a high correlation between BIA8MF and DXA in estimating total and segmental LBM, FM and percentage body fat (r = 0.909–0.986, 0.757–0.964, and 0.837–0.936, respectively). For BMC estimates, moderate to high correlations (r = 0.425–0.829) between the two methods were noted. The percentage errors and pure errors for BMC estimates between the methods ranged from 33.9% to 93.0% and from 0.159 kg to 0.969 kg, respectively. This study validated that BIA8MF can accurately assesses LBM, FM and body fat percentage (BF%). However, the estimation of segmental BMC based on the difference between FFM and LBM in body segments may not be reliable by BIA8MF.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
DXA has become the preferred method for assessing body composition, with a notable advantage being that it provides a multi-compartment assessment that includes bone.
“DXA has become the preferred method for assessing body composition, with a notable advantage being that it provides a multi-compartment assessment that includes bone [68,69].”
From The Utility of Body Composition Assessment in Nutrition and Clinical Practice: An Overview of Current Methodology (2021) · cites this paper as [68]
The Introduction describes DXA as a three-compartment method that partitions the body into fat, lean, and bone, and says it is commonly used as a reference method. It does not establish that DXA is the preferred method for body-composition assessment generally, rather than a reference method in particular contexts. (LLM, conf=0.83)
Experimental — accuracy not yet measuredWith DXA, practitioners can quantify FM, bone mineral content, and non-bone, fat-free tissue mass, thereby reducing the assumptions being relied on with SKF, ADP, and HW methods.
“With DXA, practitioners can quantify FM, bone mineral content, and non-bone, fat-free tissue mass, thereby reducing the assumptions being relied on with SKF, ADP, and HW methods [68].”
From The Utility of Body Composition Assessment in Nutrition and Clinical Practice: An Overview of Current Methodology (2021) · cites this paper as [68]
The Introduction (page not provided) describes DXA as partitioning the body into fat, lean, and bone components, and Methods §2.3 reports DXA measurements of fat mass, lean body mass, and bone mineral content. The paper does not establish that DXA reduces reliance on assumptions compared with skinfold, air-displacement plethysmography, or hydrostatic-weighing methods; it says DXA itself uses a soft-tissue assumption. (LLM, conf=0.86)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Bosy-Westphal, A., Jensen, B., Braun, W., Pourhassan, M., Gallagher, D., & Müller, M. J. (2017) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2017.27 · Cited by 231 · see citing works
Kim, M., Shinkai, S., Murayama, H., & Mori, S. (2015) · Geriatrics & Gerontology International · doi:10.1111/ggi.12384 · Cited by 221 · see citing works
Anderson, L. J., Erceg, D. N., & Schroeder, E. T. (2012) · Nutrition Research · doi:10.1016/j.nutres.2012.05.009 · Cited by 167 · cited 1× · see citing works
“, Seoul, Korea) have also been published and show variable degrees of agreement [32,36].”
BackgroundLOHMAN, T. G., HARRIS, M., TEIXEIRA, P. J., & WEISS, L. (2000) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2000.tb06420.x · Cited by 153 · see citing works
Flagged first, then by citations
Research works printed but not linked: 42
- [1]Bouchard C. Perusse L. Heredity and body fat Annu. Rev. Nutr. 1988 8 259 277 10.1146/annurev.nu.08.070188.001355 3060167 · DOI
- [2]Zemel B.S. Reley E.M. Stallings V.A. Evaluation of methodology for nutritional assessment in children: Anthropometry, body composition, and energy expenditure Annu. Rev. Nutr. 1997 17 211 235 10.1146/annurev.nutr.17.1.211 9240926 · DOI
- [3]Janssen I. Katzmarzyk P.T. Ross R. Leon A.S. Skinner J.S. Rao D.C. Wilmore J.H. Rankinen T. Bouchard C. Fitness alters the associations of BMI and waist circumference with total and abdominal fat Obes. Res. 2004 12 525 537 10.1038/oby.2004.60 15044671 · DOI
- [4]Despres J.P. The insulin resistance-dyslipidemic syndrome of visceral obesity: Effect on patients’ risk Obes. Res. 1998 6 8S 17S 10.1002/j.1550-8528.1998.tb00683.x 9569171 · DOI · Paper page
- [5]Ellis K.J. Human body composition: In Vivo method Physiol. Rev. 2000 80 649 680 10.1152/physrev.2000.80.2.649 10747204 · DOI
- [6]Kyle U.G. Bosaeus I. De Lorenzo A.D. Deurenberg P. Elia M. Gómez J.M. Heitmann B.L. Kent-Smith L. Melchior J.C. Pirlich M. Bioelectrical impedance analysis-part I: Review of principles and methods Clin. Nutr. 2004 23 1226 1243 10.1016/j.clnu.2004.06.004 15380917 · DOI · Paper page
- [7]Kyle U.G. Bosaeus I. De Lorenzo A.D. Deurenberg P. Elia M. Gómez J.M. Heitmann B.L. Kent-Smith L. Melchior J.C. Pirlich M. Bioelectrical impedance analysis-part II: Utilization in clinical practice Clin. Nutr. 2004 23 1430 1453 10.1016/j.clnu.2004.09.012 15556267 · DOI · Paper page
- [8]Pietroelli A. Formica C. Wang Z. Heymsfield S.B. Dual-energy X-ray absorptiometry body composition model: Review of physical concepts Am. J. Physiol. 1996 271 E941 E951 8997211
- [9]Kohrt W.M. Body composition by DXA: Tried and true? Med. Sci. Sports Exerc. 1995 28 1349 1353 10.1249/00005768-199510000-00001 8531604 · DOI
- [10]Tothill P. Fenner J.A. Reid D.M. Comparisons between three dual-energy X-ray absorptiometers used for measuring spine and femur Br. J. Radiol. 1995 68 621 629 10.1259/0007-1285-68-810-621 7627485 · DOI
- [11]Maw G.J. Mackenzie I.L. Taylor N.A. Redistribution of body fluids during postural manipulations Acta Physiol. Scand. 1995 155 157 163 10.1111/j.1748-1716.1995.tb09960.x 8669288 · DOI
- [12]Oshima Y. Shiga T. Within-day variability of whole-body and segmental bioelectrical impedance in a standing position Eur. J. Clin. Nutr. 2006 60 938 941 10.1038/sj.ejcn.1602402 16482076 · DOI
- [13]Mazess R.B. Peppler W.W. Chesney R.W. Lange T.A. Lindgren U. Smith E. Jr. Total body and regional bone mineral by dual-photon absorptiometry in metabolic bone disease Calcif. Tissue Int. 1984 36 8 13 10.1007/BF02405287 6423240 · DOI
- [14]Rico H. Revilla M. Villa L.F. Alvarez de Buergo M. Age-related differences in total and regional bone mass: A cross-sectional study with DXA in 429 normal women Osteoporos. Int. 1993 3 154 159 10.1007/BF01623277 8481592 · DOI
- [15]Bennell K.L. Malcolm S.A. Khan K.M. Thomas S.A. Reid S.J. Brukner P.D. Ebeling P.R. Wark J.D. Bone mass and bone turnover in power athletes, endurance athletes, and controls: A 12-month longitudinal study Bone 1997 20 477 484 10.1016/S8756-3282(97)00026-4 9145246 · DOI
- [16]Calbet J.A. Moysi J.S. Dorado C. Rodríguez L.P. Bone mineral content and density in professional tennis players Calcif. Tissue Int. 1998 62 491 496 10.1007/s002239900467 9576975 · DOI
- [17]Sinaki M. Wahner H.W. Offord K.P. Relationship between grip strength and related regional bone mineral content Arch. Phys. Med. Rehabil. 1989 70 823 826 2818154
- [18]Chen K.T. Chen Y.Y. Wang C.W. Chuang C.L. Chiang L.M. Lai C.L. Lu H.K. Dwyer G.B. Chao S.P. Shih M.K. Comparison of standing posture bioelectrical impedance analysis with DXA for body composition in a large, healthy Chinese population PLoS ONE 2016 11 e0160105 10.1371/journal.pone.0160105 27467065 PMC4965215 · DOI · Paper page
- [19]Karelis A.D. Chamberland G. Aubertin-Leheudre M. Duval C. Validation of a portable bioelectrical impedance analyzer for the assessment of body composition Appl. Physiol. Nutr. Metab. 2013 38 27 32 10.1139/apnm-2012-0129 23368825 · DOI
- [20]Lee L.W. Liao Y.S. Lu H.K. Hsiao P.L. Chen Y.Y. Chi C.C. Hsieh K.C. Validation of two portable bioelectrical impedance analyses for the assessment of body composition in school age children PLoS ONE 2017 12 e0171568 10.1371/journal.pone.0171568 28158304 PMC5291432 · DOI
- [21]Esco M.R. Snarr R.L. Leatherwood M.D. Chamberlain N.A. Redding M.L. Flatt A.A. Moon J.R. Williford H.N. Comparison of total and segmental body composition using DXA and multifrequency bioimpedance in collegiate female athletes J. Strength Cond. Res. 2015 29 918 925 10.1519/JSC.0000000000000732 25353076 · DOI · Paper page
- [22]Gibson A.L. Holmes J.C. Desautels R.L. Edmonds L.B. Nuudi L. Ability of new octapolar bioimpedance spectroscopy analyzers to predict 4-component-model percentage body fat in Hispanic, black, and white adults Am. J. Clin. Nutr. 2008 87 332 338 10.1093/ajcn/87.2.332 18258622 · DOI
- [23]De Castro J.A.C. de Lima T.R. Silva D.A.S. Body composition estimation in children and adolescents by bioelectrical impedance analysis: A systematic review J. Bodyw. Mov. Ther. 2017 22 134 146 10.1016/j.jbmt.2017.04.010 29332738 · DOI
- [24]Stone T.M. Wingo J.E. Nickerson B.S. Esco M.R. Comparison of bioelectrical impedance analysis and dual-energy x-ray absorptiometry for estimating bone mineral content Int. J. Sport. Nutr. Exerc. Metab. 2018 28 542 546 10.1123/ijsnem.2017-0185 29345171 · DOI · Paper page
- [25]Lee L.W. Liao Y.S. Lu H.K. Hsieh K.C. Chi C.C. Performance of bioelectrical impedance analysis in the estimation of bone mineral content in healthy children aged 6–12 years J. Clin. Densitom. 2019 10.1016/j.jocd.2019.03.002 30979543 · DOI
- [26]Segal K.R. Burastero S. Chum A. Coronel P. Pierson R. Wang J. Estimation of extracellular and total body water by multiple-frequency bioelectrical-impedance measurement Am. J. Clin. Nutr. 1991 54 26 29 10.1093/ajcn/54.1.26 2058583 · DOI · Paper page
- [27]Segal K.R. Van Loan M. Fitzgerald P.I. Hodgdon J.A. Van Itallie T.B. Lean body mass estimation by bioelectrical impedance analysis: A four-site cross-validation study Am. J. Clin. Nutr. 1988 47 7 14 10.1093/ajcn/47.1.7 3337041 · DOI · Paper page
- [28]Cha K. Chertow G.M. Gonzalez J. Lazarus J.M. Wilmore D.W. Multifrequency bioelectrical impedance estimates the distribution of body water J. Appl. Physiol. 1995 79 1316 1319 10.1152/jappl.1995.79.4.1316 8567578 · DOI
- [29]Bedogni G. Malavolti M. Severi S. Poli M. Mussi C. Fantuzzi A.L. Battistini N. Accuracy of an eight-point tactile-electrode impedance method in the assessment of total body water Eur. J. Clin. Nutr. 2002 56 1143 1148 10.1038/sj.ejcn.1601466 12428182 · DOI
- [30]Alkahtani S.A. A cross-sectional study on sarcopenia using different methods: Reference values for healthy Saudi young men BMC Musculoskelet. Disord. 2017 18 119 10.1186/s12891-017-1483-7 28327109 PMC5359846 · DOI
- [31]Mally K. Trentmann J. Heller M. Dittmar M. Reliability and accuracy of segmental bioelectrical impedance analysis for assessing muscle and fat mass in older Europeans: A comparison with dual-energy X-ray absorptiometry Eur. J. Appl. Physiol. 2011 111 1879 1887 10.1007/s00421-010-1795-x 21234595 · DOI · Paper page
- [33]Lukaski H.C. Johnson P.E. Bolonchuk W.W. Lykken G.I. Assessment of fat-free mass using bioelectrical impedance measurements of the human body Am. J. Clin. Nutr. 1985 41 810 817 10.1093/ajcn/41.4.810 3984933 · DOI · Paper page
- [34]Bracco D. Thiebaud D. Chiolero R.L. Landry M. Burckhardt P. Schutz Y. Segmental body composition assessed by bioelectrical impedance analysis and DEXA in humans J. Appl. Physiol. 1985 81 2580 2587 10.1152/jappl.1996.81.6.2580 9018509 · DOI
- [35]von Hurst P.R. Walsh D.C.I. Conlon C.A. Ingram M. Kruger R. Stonehouse W. Validity and reliability of bioelectrical impedance analysis to estimate body fat percentage against air displacement plethysmography and dual-energy X-ray absorptiometry Nutr. Diet. 2016 73 197 204 10.1111/1747-0080.12172 · DOI
- [37]Kim J. Shen W. Gallagher D. Jones A. Wang Z. Jr. Wang J. Heshka S. Heymsfield S.B. Total-body skeletal muscle mass: Estimation by dual-energy X-ray absorptiometry in children and adolescents Am. J. Clin. Nutr. 2006 84 1014 1020 10.1093/ajcn/84.5.1014 17093152 PMC2747777 · DOI
- [38]Kim J. Wang Z. Heymsfield S.B. Baumgartner R.N. Gallagher D. Total-body skeletal muscle mass: Estimation by a new dual-energy X-ray absorptiometry method Am. J. Clin. Nutr. 2002 76 378 383 10.1093/ajcn/76.2.378 12145010 · DOI · Paper page
- [39]Shih R. Wang Z. Heo M. Wang W. Heymsfield S.B. Lower limb skeletal muscle mass: Development of dual-energy X-ray absorptiometry prediction model J. Appl. Physiol. 1985 89 1380 1386 10.1152/jappl.2000.89.4.1380 11007572 · DOI
- [40]Furstenberg A. Davenport A. Comparison of multifrequency bioelectrical impedance analysis and dual-energy X-ray absorptiometry assessments in outpatient hemodialysis patients Am. J. Kidney Dis. 2011 57 123 129 10.1053/j.ajkd.2010.05.022 20692749 · DOI
- [41]Ling C.H. de Craen A.J. Slagboom P.E. Gunn D.A. Stokkel M.P. Westendorp R.G. Maier A.B. Accuracy of direct segmental multi-frequency bioimpedance analysis in the assessment of total body and segmental body composition in middle-aged adult population Clin. Nutr. 2011 30 610 615 10.1016/j.clnu.2011.04.001 21555168 · DOI
- [44]Genton L. Hans D. Kyle U.G. Pichard C. Dual-energy X-ray absorptiometry and body composition: Differences between devices and comparison with reference methods Nutrition 2002 18 66 70 10.1016/S0899-9007(01)00700-6 11827768 · DOI
- [45]Toombs R.J. Ducher G. Shepherd J.A. De Souza M.J. The impact of recent technological advances on the trueness and precision of DXA to assess body composition Obesity 2011 20 30 39 10.1038/oby.2011.211 21760631 · DOI
- [46]Deurenberg P. Limitations of the bioelectrical impedance method for the assessment of body fat in severe obesity Am. J. Clin. Nutr. 1996 64 449S 452S 10.1093/ajcn/64.3.449S 8780361 · DOI
Cited by
Sorted by citations
Holmes, C. J., & Racette, S. B. (2021) · Nutrients · doi:10.3390/nu13082493 · Cited by 402 · see citing works
- Authors
- Liao, Y.-S., Li, H.-C., Lu, H.-K., Lai, C.-L., Wang, Y.-S., & Hsieh, K.-C.
- Affiliations
- Chang Gung University of Science and Technology (TW)
- Chang Gung Memorial Hospital (TW)
- National Taiwan University of Sport (TW)
- Asia University (TW)
- Department of Diagnostic Radiology, Chang Gung Memorial Hospital, Chiayi613, Taiwan
- National Chin-Yi University of Technology (TW)
- Corresponding author
- Hsieh, Kuen-Chang
- Venue
- International Journal of Environmental Research and Public Health
- Publisher
- MDPI AG
- Published
- 2020-04-10
- Volume
- 17
- Issue
- 7
- Pages
- 2595
- ISSN
- 1660-4601 (ISSN-L)
- PMC
- PMC7177846
- OpenAlex
- W3015444662
- Cited by
- 48
- References
- 4
- Citations by year
- 2026: 2 · 2025: 10 · 2024: 7 · 2023: 6 · 2022: 9 · 2021: 11 · 2020: 3
- FWCI
- 4.36
- Type
- journal article
- Language
- en
- Open access
- gold
- dx.doi.org
- Licence
- Locations
- International Journal of Environmental Research and Public Health (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- Chang Gung Medical Foundation (CMRPG6D0271)
- Topics
- Health Sciences › Medicine › Physiology › Body Composition Measurement Techniques
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Emergency Medicine › HIV-related health complications and treatments
- Keywords
- bioelectrical impedance analysis, dual-energy X-ray absorptiometry, bone mineral content, three-compartment model, fat-free mass, lean body mass, fat mass, body fat percentage, body composition assessment, method comparison
- MeSH terms
- Adipose Tissue, Adult, Body Composition, Cross-Sectional Studies, Female, Humans, Male, Middle Aged, Taiwan, Absorptiometry, Photon, Bone Density, Electric Impedance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review