Influence of mechanical loading on myosin heavy-chain protein and mRNA isoform expression
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The overall objective of the studies reported herein was to examine the effects of high-resistance training on myosin heavy-chain (MHC) protein and mRNA isoform expression. The findings from these studies can be summarized as follows: 1) there was a substantial increase in the fast type IIX MHC protein isoform content of the trained red and white medial gastrocnemius muscles, but this did not occur until after the eighth training session (i.e., 16 days); 2) single-fiber analyses demonstrated that many so-called fast type IIB fibers contained small amounts of the fast type IIX MHC protein isoform and that the high-resistance training program altered the bias of fast type IIB-type IIX MHC protein isoform distribution in these fibers but did not increase the number of fibers that could be categorized as exclusively fast type IIX fibers; 3) the high-resistance training program produced a rapid (i.e., after two training sessions) elevation in the fast type IIX MHC mRNA isoform and a corresponding repression of the fast type IIB MHC mRNA isoform; and 4) the dose-response study revealed that as few as 10 contractions (40 s) per training session were capable of elevating the expression of the fast type IIX MHC mRNA isoform by approximately 250%. These collective findings demonstrate that high-resistance training is a powerful modulator of MHC protein isoforms and that pretranslational mechanisms are very sensitive to even small amounts of high-resistance training.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Izumo, S., Nadal-Ginard, B., & Mahdavi, V. (1986) · Science · doi:10.1126/science.3945800 · Cited by 621
Cited by
Hortobágyi, T., Dempsey, L., Fraser, D., Zheng, D., Hamilton, G., Lambert, J., & Dohm, L. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.00293.x · Cited by 354
Baldwin, K. M., & Haddad, F. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.1.345 · Cited by 312
Self-citationKimball, S. R., Farrell, P. A., & Jefferson, L. S. (2002) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00221.2002 · Cited by 296
Egan, B., & Sharples, A. P. (2023) · Physiological Reviews · doi:10.1152/physrev.00054.2021 · Cited by 278
Mechanisms Modulating Skeletal Muscle Phenotype
Blaauw, B., Schiaffino, S., & Reggiani, C. (2013) · Comprehensive Physiology · doi:10.1002/cphy.c130009 · Cited by 256
Metadata
- Authors
- Caiozzo, V. J., Haddad, F., Baker, M. J., & Baldwin, K. M.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1996-05-01
- Volume
- 80
- Issue
- 5
- Pages
- 1503-1512
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2105233153
- Cited by
- 84
- References
- 1
- FWCI
- 2.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.